PURPOSE: We have previously reported that fixation loss (FL) rates, false-positive (FP) rates, and gaze tracking (GT) parameters (average tracking failure frequency per stimulus [TFF], average blinking frequency [BF], average frequency of eye movements between 1° and 2° [move1-2], between 3° and 5° [move3-5], and equal to or more than 6° [move≥6]) are related to the over- or underestimation of visual field (VF) results. The purpose of the current study was to validate these results by investigating the effect of implementing the GT parameters on the relationship between VF results and optical coherence tomography (OCT) measurements.
METHODS: Two hundred forty-four eyes of 155 open-angle glaucoma patients were included. Vision fixation during VF tests with the Humphrey Field Analyzer (24-2 SITA standard) was evaluated using the gaze fixation chart at the bottom of the VF printout. Mean total deviation (mTD) values were calculated, and their relationship with OCT-determined circumpapillary retinal nerve fiber layer (cp-RNFL), OCT-determined macular ganglion cell complex (GCC) thickness, and axial length was investigated using the corrected Akaike Information Criterion (AICc) in linear mixed modeling.
RESULTS: In the best model, average total cpRNFL thickness, average total GCC thickness, axial length, FL, FP, move3-5, move≥6, TFF, and BF were selected as significant predictors (mTD = 2.1 + 0.097 × average total cpRNFL thickness + 0.089 × average total GCC thickness - 0.94 × axial length + 2.7 × FL + 7.2 × FP - 7.0 × move3-5 - 1.8 × move≥6 - 4.2 × TFF - 1.7 × BF).
CONCLUSIONS: Both GT parameters and classic VF reliability indices had significant influence on the structure-function relationship analysis in glaucoma.

Entities:  

Year:  2015        PMID: 26650899     DOI: 10.1167/iovs.15-17988

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  12 in total

1.  Association of Visual Field Pattern Reversal with Paracentral Visual Field Loss.

Authors:  Aimee C Chang; Andrew S Camp; Vincent M Patella; Robert N Weinreb
Journal:  Ophthalmol Glaucoma       Date:  2021-10-21

2.  Assessing Visual Fields in Patients with Retinitis Pigmentosa Using a Novel Microperimeter with Eye Tracking: The MP-3.

Authors:  Nozomi Igarashi; Masato Matsuura; Yohei Hashimoto; Kazunori Hirasawa; Hiroshi Murata; Tatsuya Inoue; Obata Ryo; Makoto Aihara; Ryo Asaoka
Journal:  PLoS One       Date:  2016-11-28       Impact factor: 3.240

3.  Smaller Fixation Target Size Is Associated with More Stable Fixation and Less Variance in Threshold Sensitivity.

Authors:  Kazunori Hirasawa; Kana Okano; Risako Koshiji; Wakana Funaki; Nobuyuki Shoji
Journal:  PLoS One       Date:  2016-11-09       Impact factor: 3.240

4.  The association between visual function and retinal structure in chronic central serous chorioretinopathy.

Authors:  Aya Sugiura; Ryosuke Fujino; Nobuko Takemiya; Kimiko Shimizu; Masato Matsuura; Hiroshi Murata; Tatsuya Inoue; Ryo Obata; Ryo Asaoka
Journal:  Sci Rep       Date:  2017-11-24       Impact factor: 4.379

5.  Exploring Test-Retest Variability Using High-Resolution Perimetry.

Authors:  Takuya Numata; Ted Maddess; Chota Matsumoto; Sachiko Okuyama; Shigeki Hashimoto; Hiroki Nomoto; Yoshikazu Shimomura
Journal:  Transl Vis Sci Technol       Date:  2017-10-04       Impact factor: 3.283

6.  Comparison of Humphrey Field Analyzer and imo visual field test results in patients with glaucoma and pseudo-fixation loss.

Authors:  Hiroyasu Goukon; Kazunori Hirasawa; Masayuki Kasahara; Kazuhiro Matsumura; Nobuyuki Shoji
Journal:  PLoS One       Date:  2019-11-07       Impact factor: 3.240

7.  Standard Reliability and Gaze Tracking Metrics in Glaucoma and Glaucoma Suspects.

Authors:  Andrew Steven Camp; Christopher P Long; Vincent Michael Patella; James A Proudfoot; Robert N Weinreb
Journal:  Am J Ophthalmol       Date:  2021-07-17       Impact factor: 5.488

8.  The association between structure-function relationships and cognitive impairment in elderly glaucoma patients.

Authors:  Megumi Honjo; Jiro Numaga; Tadashi Hara; Ryo Asaoka
Journal:  Sci Rep       Date:  2017-08-02       Impact factor: 4.379

9.  The structure-function relationship measured with optical coherence tomography and a microperimeter with auto-tracking: the MP-3, in patients with retinitis pigmentosa.

Authors:  Yuichi Asahina; Marie Kitano; Yohei Hashimoto; Mieko Yanagisawa; Hiroshi Murata; Tatsuya Inoue; Ryo Obata; Ryo Asaoka
Journal:  Sci Rep       Date:  2017-11-17       Impact factor: 4.379

10.  The Human Touch: Using a Webcam to Autonomously Monitor Compliance During Visual Field Assessments.

Authors:  Pete R Jones; Giorgia Demaria; Iris Tigchelaar; Daniel S Asfaw; David F Edgar; Peter Campbell; Tamsin Callaghan; David P Crabb
Journal:  Transl Vis Sci Technol       Date:  2020-07-20       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.