Aya Sugiura1, Ryosuke Fujino1, Nobuko Takemiya1, Kimiko Shimizu1, Masato Matsuura1, Hiroshi Murata1, Tatsuya Inoue1, Ryo Obata1, Ryo Asaoka2.
Abstract
The purpose of the current study was to investigate the association between visual function and retinal structure in central serous chorioretinopathy (CSC). In 22 eyes of 22 chronic CSC patients with serous retinal detachment at the macula, retinal sensitivity was measured using MP3 microperimetry (NIDEK, Japan) and mean sensitivity within two degrees (MS2), four degrees (MS4) and six degrees (MS6), as well as foveal sensitivity (MS0), were calculated. Retinal structure was measured using optical coherence tomography (OCT, Spectralis, Heidelberg). The relationship between visual function (LogMAR best-corrected visual acuity [LogMAR VA] and MS0, MS2, MS4, MS6) and serous retinal detachment height at the fovea (SRDH), central retinal thickness (CRT), macular volume (MV) and central choroidal thickness (CCT) was investigated. There were significant negative correlations between LogMAR VA and MS0 (p = 0.016), MS2 (p = 0.049). No significant relationship was observed between LogMAR VA and SRDH (p = 0.97) although there was a significant negative correlation between SRDH and MS2 (p = 0.028), MS4 (p = 0.049), MS6 (p = 0.023). In conclusion, in CSC, serous retinal detachment was significantly correlated with retinal sensitivity measured with MP3, but not with LogMAR VA.Entities:
Mesh:
Year: 2017 PMID: 29176603 PMCID: PMC5701134 DOI: 10.1038/s41598-017-16339-9
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1Example VF measurement with the MP-3 Perimetry results of a 53 years old male with CSC. VF: visual field, CSC: Central Serous Chorioretinopathy.
Figure 2Macular volume measurement Macular volume within 1 mm diameter (MV1), 2 mm diameter (MV2), 3 mm diameter (MV3) were evaluated using OCT measurement OCT: optical coherence tomography.
Subjects demographics.
| variables | value |
|---|---|
| age (years), mean ± SD [range] | 54.6 ± 12.3 [37 to 77] |
| gender, male:female | 16:6 |
| eye, righ:left | 11:11 |
| LogMAR VA, mean ± SD [range] | 0.17 ± 0.25 [−0.079 to 0.70] |
| MS0 (dB), mean ± SD [range] | 16.2 ± 5.2 [4.0 to 25.0] |
| MS2 (dB), mean ± SD [range] | 19.6 ± 5.7 [4.9 to 28.8] |
| MS4 (dB), mean ± SD [range] | 20.8 ± 6.0 [4.9 to 29.0] |
| MS6 (dB), mean ± SD [range] | 21.7 ± 5.2 [11.4 to 29.1] |
| CRT (μm), mean ± SD [range] | 331.1 ± 93.1 [213.5 to 507.5] |
| SRD (μm), mean ± SD [range] | 132.6 ± 94.2 [10.0 to 324.0] |
| MV1 (μm3), mean ± SD [range] | 0.27 ± 0.070 [0.18 to 0.41] |
| MV2 (μm3), mean ± SD [range] | 1.16 ± 0.24 [0.82 to 1.71] |
| MV3 (μm3), mean ± SD [range] | 2.58 ± 0.45 [1.92 to 3.69] |
| CCT (μm), mean ± SD [range] | 317.8 ± 79.4 [185.0 to 436.0] |
| Disease duration (months), mean ± SD [range] | 17.4 ± 9.8 [3 to 33] |
SD: standard deviation, VA: visual acuity, MS0: mean sensitivity at fovea, MS2: mean sensitivity within two degrees, MS4: mean sensitivity within four degrees, MS6: mean sensitivity within six degrees, SRDH: serous retinal detachment height, CRT: central retinal thickness, MV1: macular volume within 1 mm diameter, MV2: macular volume within 2 mm diameter, MV3: macular volume within 3 mm diameter, CCT: central choroidal thickness, Disease duration was collected from 46 eyes of 40 patients.
Figure 3The relationship between LogMAR VA and SRDH No significant relationship was observed between LogMAR VA and SRDH (coefficient = −7.1 × 10−4, p = 0.22, linear regression). SRDH: serous retinal detachment height.
Figure 4The relationship between MP-3 measured retinal sensitivities and SRDH A: MS0 and SRDH, significant relationship was not observed (coefficient = −0.015, p = 0.24), B: MS2 and SRDH, significant relationship was observed (coefficient = −0.029, p = 0.027), C: MS4 and SRDH, significant relationship was observed (coefficient = −0.031, p = 0.024), and D: MS6 and SRDH, significant relationship was observed (coefficient = −0.030, p = 0.0087). SRDH: serous retinal detachment height, MS0: mean sensitivity at fovea, MS2: mean sensitivity within two degrees, MS4: mean sensitivity within four degrees, MS6: mean sensitivity within six degrees.
Relationship between LogMAR VA and microperimetry measured retinal sensitivities and, OCT-measured thicknesses in the retina.
| LogMAR VA | MS0 | MS2 | |||||||
|---|---|---|---|---|---|---|---|---|---|
| coefficient | SE | p value | coefficient | SE | p value | coefficient | SE | p value | |
| SRDH | 2.6 × 10−5 | 6.7 × 10−4 | 0.97 | −0.025 | 0.015 | 0.11 | −0.035 | 0.015 | 0.028 |
| MV1 | −1.7 | 0.90 | 0.078 | 22.9 | 19.9 | 0.27 | 16.1 | 20.1 | 0.43 |
| MV2 | — | — | — | — | — | — | — | — | — |
| MV3 | — | — | — | — | — | — | — | — | — |
|
| MS6 | ||||||||
|
|
|
|
|
|
| ||||
| SRDH | −0.035 | 0.017 | 0.049 | −0.033 | 0.013 | 0.023 | |||
| MV1 | — | — | — | — | — | — | |||
| MV2 | 2.60 | 6.43 | 0.69 | — | — | — | |||
| MV3 | — | — | — | 0.93 | 2.74 | 0.74 | |||
VA: visual acuity, OCT: optical coherence tomography, SE: standard error, MS0: mean sensitivity at fovea, MS2: mean sensitivity within two degrees, MS4: mean sensitivity within four degrees, MS6: mean sensitivity within six degrees, SRDH: serous retinal detachment height, MV1: macular volume within 1 mm diameter, MV2: macular volume within 2 mm diameter, MV3: macular volume within 3 mm diameter.