Erdem Özel1, Ahmet Taştan, Ali Öztürk, Emin Evren Özcan, Samet Uyar, Ömer Şenarslan.
Abstract
OBJECTIVE: The bioresorbable vascular scaffold system (BVS) is a fully absorbable vascular treatment system. In this study, we aimed to compare the periprocedural effectiveness and long term results of non-compliant balloon (NCB) and compliant balloon (CB) systems, which are used for predilatation before BVS implantation.Entities:
Mesh:
Year: 2015 PMID: 26642470 PMCID: PMC5368433 DOI: 10.5152/AnatolJCardiol.2015.6184
Source DB: PubMed Journal: Anatol J Cardiol ISSN: 2149-2263 Impact factor: 1.596
Clinical presentation and lesion characteristics
| NCB n=59, n=72 BVS (%) | CB n=60, n=74 BVS (%) | ||
|---|---|---|---|
| Age, years | 61.1±9.4 | 61.5±9.6 | 0.834 |
| Male gender | 53 (89.8) | 47 (78.3) | 0.132 |
| Diabetes | 20 (33.9) | 23 (38.3) | 0.614 |
| Hypertension | 48 (81.4) | 48 (80) | 1 |
| Hyperlipidemia | 28 (47.5) | 34 (56.7) | 0.361 |
| Smoking | 24 (40.7) | 16 (26.7) | 0.123 |
| Chronic renal failure | 3 (5.1) | 2 (3.3) | 0.679 |
| Prior MI | 27 (45.8) | 28 (46.7) | 1 |
| Prior PCI | 20 (33.9) | 20 (33.3) | 1 |
| Prior CABG | 6 (10.2) | 11 (18.3) | 0.295 |
| Radial intervention | 24 (40.7) | 21 (35) | 0.573 |
| Acute coronary syndrome | 34 (57.7) | 36 (60) | 0.853 |
| Stable angina | 21 (35.6) | 17 (28.3) | 0.436 |
| Silent ischemia | 4 (6.8) | 7 (11.7) | 0.529 |
| Target vessel | |||
| LAD | 39 (54.2) | 31 (41.9) | 0.185 |
| CX | 14 (19.4) | 21 (28.4) | 0.247 |
| RCA | 19 (26.4) | 22 (29.7) | 0.714 |
| A | 16 (22.2) | 22 (29.7) | 0.348 |
| B1 | 26 (36.1) | 20 (27) | 0.377 |
| B2 | 28 (38.9) | 32 (43.2) | 0,617 |
| C | 2 (2.8) | - | 0.241 |
| ASA | 58 (98.3) | 59 (98.3) | 1 |
| Clopidogrel | 55 (93.2) | 56 (93.3) | 1 |
| Prasugrel | 2 (3.4) | 2 (3.3) | 1 |
| Ticagrelor | - | 3 (5) | 0.244 |
| Statin | 48 (81.4) | 50 (83.3) | 0.814 |
| Beta-blocker | 50 (84.7) | 52 (86.7) | 0.799 |
Chi-square test was performed CABG - coronary artery bypass graft; CB - compliant balloon; CX - circumflex artery; LAD - left anterior descending artery; MI - myocardial infarction; NCB - non compliant balloon; PCI - percutaneous coronary intervention; RCA - right coronary artery
Procedural characteristics
| NCB n=72 BVS | CB n=74 BVS | ||
|---|---|---|---|
| Lesion length, mm | 20.3±4.9 | 19.4±5.1 | 0.304 |
| Stenosis value, % | 90.5±7.9 | 91.2±7.1 | 0.555 |
| Predilatation baloon diameter, mm | 2.8±0.4 | 2.7±0.4 | 0.274 |
| Predilatation inflation pressure, mm Hg | 14.6±1.4 | 14.5±1.2 | 0.588 |
| Postdilatation rate | 26 (36.1%) | 41 (55.4%) | 0.021 |
| BVS diameter, mm | 2.9±0.35 | 2.9±0.38 | 0.332 |
| BVS length, mm | 23.1±5 | 22.1±5.2 | 0.235 |
| RVD-preimplantation, mm | 2.4±0.28 | 2.4±0.32 | 0.651 |
| RVD-post-implantation, mm | 2.8±0.31 | 2.7±0.35 | 0.582 |
| MLD-preimplantation, mm | 0.79±0.13 | 0.8±0.13 | 0.130 |
| MLD- after BVS implantation, mm | 2.63±0.32 | 2.48±0.35 | 0.010 |
| MLD-post-procedure, mm | 2.7±0.31 | 2.7±0.34 | 0.875 |
| Procedure time, min | 30±7.2 | 34±7.2 | <0.001 |
| Fluoro time, min | 8.5±2.3 | 9.9±2.5 | 0.001 |
| Contrast volume, mL | 95.2±24.8 | 109.3±23.3 | 0.001 |
Independent sample t-test was peformed BVS - bioresorbable vascular scaffold; CB - compliant balloon; MLD - minimal lumen diameter; NCB - non compliant balloon; RVD - reference vessel diameter
Clinical outcomes between groups
| NCB n=59 | CB n=60 | ||
|---|---|---|---|
| Death | - | - | - |
| MI | - | - | - |
| Angina | 1 (1.7%) | 2 (3.3%) | 1 |
| CABG | - | - | - |
| TLR | - | - | - |
| TVR | - | - | - |
| Definite BVS thrombosis | - | - | - |
| Probable stent thrombosis | - | - | - |
| Death | - | - | - |
| MI | - | 1 (1.7%) | 1 |
| Angina | 9 (15.3%) | 8 (13.3%) | 0.799 |
| CABG | - | - | - |
| TLR | - | 1 (1.7%) | 1 |
| TVR | 2 (3.4%) | 2 (3.3%) | 1 |
| Definite BVS thrombosis | - | 1 (1.7%) | 1 |
| Probable stent thrombosis | - | - | - |
Independent sample t test was performed BVS - bioresorbable vascular scaffold; CABG - coronary artery bypass graft; CB - compliant balloon; MI - myocardial infarction; NCB - non-compliant balloon; TLR - target lesion revascularization; TVR - target vessel revascularization