Literature DB >> 26634646

Liquid chromatography-electron ionization tandem mass spectrometry with the Direct-EI interface in the fast determination of diazepam and flunitrazepam in alcoholic beverages.

Giorgio Famiglini1, Veronica Termopoli1, Pierangela Palma1, Achille Cappiello1.   

Abstract

This is the first application based on electron ionization (EI) using a Direct-EI LC interface and MS/MS to detect unequivocally target compounds in a very small real sample. The determination and quantification of benzodiazepines in very small residues of beverages, collected at the scene of drug-facilitated crimes are mandatory in legal procedures. A specific and sensitive analytical instrumentation is needed, involving little or no sample preparation. Here, a direct flow injection analysis of alcoholic beverages spiked with commercially available drugs containing diazepam and flunitrazepam is presented. The method proposed is very fast and requires neither sample preparation nor chromatographic separation. Linearity (R(2) ) was between 0.9977 and 0.9992; LOD and LOQ spanned from 0.01 to 0.02 ng/μL and from 0.1 to 0.5 ng/μL, respectively; intra- and interday repeatabilities were between 1 and 8%. No matrix effects were observed from the comparison of the linear regression curves obtained in real fortified samples and in pure ethanol. Vodka, whisky, and white wine specimens were fortified with commercial drugs, Valium(®) and Rohypnol(®) , at two different concentrations (20 and 50 ng/μL) to simulate the typical amounts found in adulterated real samples and analyzed to demonstrate the method applicability to forensic analyses.
© 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Alcoholic beverages; Benzodiazepines; Direct EI LC-MS interface; MS/MS

Mesh:

Substances:

Year:  2016        PMID: 26634646     DOI: 10.1002/elps.201500517

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  3 in total

Review 1.  Interpol review of controlled substances 2016-2019.

Authors:  Nicole S Jones; Jeffrey H Comparin
Journal:  Forensic Sci Int Synerg       Date:  2020-05-24

2.  All solid-state miniaturized potentiometric sensors for flunitrazepam determination in beverages.

Authors:  Mahmoud A Tantawy; Ekram H Mohamed; Ali M Yehia
Journal:  Mikrochim Acta       Date:  2021-05-19       Impact factor: 5.833

3.  Development of a Flow Injection System for Differential Pulse Amperometry and Its Application for Diazepam Determination.

Authors:  Vesna Antunović; Slavna Tešanović; Danica Perušković; Nikola Stevanović; Rada Baošić; Snežana Mandić; Aleksandar Lolić
Journal:  J Anal Methods Chem       Date:  2018-03-19       Impact factor: 2.193

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.