Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190.

Pei-Jan P Lin1, Beth A Schueler2, Stephen Balter3, Keith J Strauss4, Kevin A Wunderle5, M Terry LaFrance6, Don-Soo Kim7, Richard H Behrman8, S Jeff Shepard9, Ishtiaq H Bercha10.   

Abstract

Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, "dose-area-product" (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term "DAP-meter" has been revised to air kerma-area product (KAP) meter. The charge of TG 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the "Accuracy and Calibration of Integrated Radiation Output Indicators" which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical "meter." To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.

Entities:  

Mesh:

Year:  2015        PMID: 26632039     DOI: 10.1118/1.4934831

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Reduced Patient Radiation Exposure during Neurodiagnostic and Interventional X-Ray Angiography with a New Imaging Platform.

Authors:  K van der Marel; S Vedantham; I M J van der Bom; M Howk; T Narain; K Ty; A Karellas; M J Gounis; A S Puri; A K Wakhloo
Journal:  AJNR Am J Neuroradiol       Date:  2017-01-19       Impact factor: 3.825

2.  High filtration in interventional practices reduces patient radiation doses but not always scatter radiation doses.

Authors:  Roberto M Sanchez; Eliseo Vano; Pablo Salinas; Nieves Gonzalo; Javier Escaned; Jose M Fernández
Journal:  Br J Radiol       Date:  2020-11-24       Impact factor: 3.039

3.  Effect of fluoroscopic X-ray beam spectrum on air-kerma measurement accuracy: implications for establishing correction coefficients on interventional fluoroscopes with KAP meters.

Authors:  Kevin A Wunderle; Joseph T Rakowski; Frank F Dong
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

4.  Development of Portable Digital Radiography System with a Device for Monitoring X-ray Source-Detector Angle and Its Application in Chest Imaging.

Authors:  Tae-Hoon Kim; Dong-Woon Heo; Chang-Won Jeong; Jong-Hyun Ryu; Hong Young Jun; Seung-Jun Han; Taeuk Ha; Kwon-Ha Yoon
Journal:  Sensors (Basel)       Date:  2017-03-07       Impact factor: 3.576

5.  Vendor-independent skin dose mapping application for interventional radiology and cardiology.

Authors:  Marko Krajinović; Nikola Kržanović; Olivera Ciraj-Bjelac
Journal:  J Appl Clin Med Phys       Date:  2021-01-13       Impact factor: 2.102

6.  Effect of equalization filters on measurements with kerma-area product meter in a cardiovascular angiography system.

Authors:  Nao Ichikawa; Atsushi Fukuda; Takuma Hayashi; Kosuke Matsubara
Journal:  J Appl Clin Med Phys       Date:  2021-10-05       Impact factor: 2.102

7.  AAPM Medical Physics Practice Guideline 12.a: Fluoroscopy dose management.

Authors:  Ryan F Fisher; Kimberly E Applegate; Lindsey K Berkowitz; Olav Christianson; Jaydev K Dave; Lindsay DeWeese; Nichole Harris; Mary Ellen Jafari; A Kyle Jones; Robert J Kobistek; Brendan Loughran; Loren Marous; Donald L Miller; Beth Schueler; Bryan C Schwarz; Adam Springer; Kevin A Wunderle
Journal:  J Appl Clin Med Phys       Date:  2022-02-17       Impact factor: 2.102

8.  Application of reference air kerma alert levels for pediatric fluoroscopic examinations.

Authors:  Elanchezhian Somasundaram; Samuel L Brady; Keith J Strauss
Journal:  J Appl Clin Med Phys       Date:  2022-08-04       Impact factor: 2.243

9.  Determination of geometric information and radiation field overlaps on the skin in percutaneous coronary interventions with computer-aided design-based X-ray beam modeling.

Authors:  Atsushi Fukuda; Pei-Jan P Lin; Nao Ichikawa; Kosuke Matsubara
Journal:  J Appl Clin Med Phys       Date:  2021-10-26       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.