Literature DB >> 26628831

Correlation of measurement of optic nerve sheath diameter with ultrasound and magnetic resonance imaging.

Shakti Bedanta Mishra1, Afzal Azim1, Syed Nabeel Muzaffar1.   

Abstract

Entities:  

Year:  2015        PMID: 26628831      PMCID: PMC4637966          DOI: 10.4103/0972-5229.167055

Source DB:  PubMed          Journal:  Indian J Crit Care Med        ISSN: 0972-5229


× No keyword cloud information.
Sir, The article by Shirodkar et al.[1] on the correlation of measurement of optic nerve sheath diameter (ONSD) measured using ultrasound and magnetic resonance imaging (MRI) was very interesting. ONSD measurement has been correlated well with raised intracranial pressure.[2] Bedside measurement of ONSD by ultrasound offers a very important advantage over other modalities and helps in early initiation of treatment. This has been a very well done study, but we believe the study could have been improved if the following points were considered: The study does not tell us who has done the ultrasonographic examination. It is very important if the study shows that examination done by an intensivist is having good correlation with MRI. The experience of the person doing the ultrasonography is also important as most previous studies have been done by experienced radiologists The inter and inter observer variations are not noted both in the ultrasonographic and MRI examination.[3] These are important sources of error in studies where an individual's observations are taken in the calculation. Most of the studies on ONSD have used two people for performing the ultrasonography and the mean value of both the observers are taken into account.[4] It would have been better if two persons were given the task of doing ultrasonography and reporting of the MRI for the same reading Potgieter et al.[5] have shown that 4-h workshop was sufficient to teach novice ultrasonographers to learn measurement of ONSD. The study could have added some data on the training needed to do an examination. This has been a very well done study, but the above would have helped in increasing our knowledge in the field of measurement of ONSD. It would have added to bedside management by an intensivist, the training and would have helped to establish the role of ultrasound in diagnosis, monitoring and management of raised intracerebral pressure.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  5 in total

1.  Intra- and interobsever reliability of sonographic assessment of the optic nerve sheath diameter in healthy adults.

Authors:  Jochen Bäuerle; Piergiorgio Lochner; Manfred Kaps; Max Nedelmann
Journal:  J Neuroimaging       Date:  2010-12-01       Impact factor: 2.486

2.  Can accurate ultrasonographic measurement of the optic nerve sheath diameter (a non-invasive measure of intracranial pressure) be taught to novice operators in a single training session?

Authors:  D W Potgieter; A Kippin; F Ngu; C McKean
Journal:  Anaesth Intensive Care       Date:  2011-01       Impact factor: 1.669

3.  Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study.

Authors:  Chetan G Shirodkar; S Manimala Rao; Dnyaneshwar P Mutkule; Yogesh R Harde; Pradeep M Venkategowda; M Uma Mahesh
Journal:  Indian J Crit Care Med       Date:  2014-11

4.  Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position.

Authors:  Ji-Hyun Chin; Hyungseok Seo; Eun-Ho Lee; Joohyun Lee; Jun Hyuk Hong; Jai-Hyun Hwang; Young-Kug Kim
Journal:  BMC Anesthesiol       Date:  2015-03-31       Impact factor: 2.217

5.  Correlation of measurement of optic nerve sheath diameter using ultrasound with magnetic resonance imaging.

Authors:  Chetan G Shirodkar; Kartik Munta; S Manimala Rao; M Uma Mahesh
Journal:  Indian J Crit Care Med       Date:  2015-08
  5 in total
  1 in total

1.  Correlation of measurement of optic nerve sheath diameter with ultrasound and magnetic resonance imaging.

Authors:  Munta Kartik; Manimala S Rao
Journal:  Indian J Crit Care Med       Date:  2016-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.