Literature DB >> 26627586

A europium- and terbium-coated magnetic nanocomposite as sorbent in dispersive solid phase extraction coupled with ultra-high performance liquid chromatography for antibiotic determination in meat samples.

M L Castillo-García1, M P Aguilar-Caballos1, A Gómez-Hens2.   

Abstract

A new magnetic dispersive solid-phase extraction approach based on Eu- and Tb-coated magnetic nanocomposites, combined with ultra-high performance liquid chromatography with fluorometric detection, is reported for the extraction and simultaneous determination of veterinary antibiotics. The method is aimed at monitoring of potential residues of three tetracyclines, namely oxytetracycline, tetracycline, chlortetracycline and three acidic quinolones, such as oxolinic acid, nalidixic acid and flumequine, chosen as model analytes, in animal muscle samples. The nanocomposites were obtained by synthesizing magnetic nanoparticles by a co-precipitation method and their coating with terbium and europium ions. The limits of detection obtained using standard solutions were: 1.0, 1.5, 3.8, 0.25, 0.7 and 1.2ngmL(-1), which corresponds to 3.3, 5.0, 12.7, 0.8, 2.3 and 4.0μgkg(-1) for oxytetracycline, tetracycline, chlortetracycline, oxolinic acid, nalidixic acid and flumequine, respectively, in meat samples. The precision values, obtained in the presence of the sample matrix, were in the ranges 0.12-2.0% and 2.6-15.4% for retention times and areas, respectively. The selectivity of the method was checked by assaying different veterinary drugs, finding that most of them did not interfere at the same concentration levels as that of analytes. A recovery study was performed in the presence of chicken and pork muscle samples, which provided values in the range of 61.5-102.6%.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Eu- and Tb-coated magnetic nanoparticles; Fluorometric detection; Meat samples; Quinolones; Tetracyclines; Ultra-performance liquid chromatography

Mesh:

Substances:

Year:  2015        PMID: 26627586     DOI: 10.1016/j.chroma.2015.11.048

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

Review 1.  Dispersive Solid Phase Extraction for the Analysis of Veterinary Drugs Applied to Food Samples: A Review.

Authors:  Gabriela Islas; Israel S Ibarra; Prisciliano Hernandez; Jose M Miranda; Alberto Cepeda
Journal:  Int J Anal Chem       Date:  2017-10-18       Impact factor: 1.885

2.  Europium Fluorescent Nanoparticles-Based Multiplex Lateral Flow Immunoassay for Simultaneous Detection of Three Antibiotic Families Residue.

Authors:  Yaping Wang; Biao Ma; Miaomiao Liu; Erjing Chen; Ying Xu; Mingzhou Zhang
Journal:  Front Chem       Date:  2021-12-20       Impact factor: 5.221

Review 3.  Quinolone Complexes with Lanthanide Ions: An Insight into their Analytical Applications and Biological Activity.

Authors:  Ana-Mădălina Măciucă; Alexandra-Cristina Munteanu; Valentina Uivarosi
Journal:  Molecules       Date:  2020-03-16       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.