Literature DB >> 26624974

Potential Heating Effect in the Gravid Uterus by Using 3-T MR Imaging Protocols: Experimental Study in Miniature Pigs.

Mieke M Cannie1, Frederik De Keyzer1, Sigrid Van Laere1, Astrid Leus1, Johan de Mey1, Catherine Fourneau1, Filip De Ridder1, Toon Van Cauteren1, Inneke Willekens1, Jacques C Jani1.   

Abstract

Purpose To determine the changes in temperature within the gravid miniature pig uterus during magnetic resonance (MR) imaging at 3 T. Materials and Methods The study received ethics committee approval for animal experimentation. Fiber-optic temperature sensors were inserted into the fetal brain, abdomen, bladder, and amniotic fluid of miniature pigs (second trimester, n = 2; third trimester, n = 2). In the first trimester (n = 2), the sensors were inserted only into the amniotic fluid (three sacs per miniature pig, for a total of six sacs). Imaging was performed with a 3-T MR imager by using different imaging protocols in a random order for animal, each lasting approximately 15 minutes. The first regimen consisted of common sequences used for human fetal MR examination, including normal specific absorption rate (SAR). The second regimen consisted of five low-SAR sequences, for which three gradient-echo sequences were interspersed with two diffusion-weighted imaging series. Finally, a high-SAR regimen maximized the radiofrequency energy deposition (constrained by the 2-W per kilogram of body weight SAR limitations) by using five single-shot turbo spin-echo sequences. Differences in temperature increases between the three regimens and between the three trimesters were evaluated by using one-way analysis of variance. The maximum cumulative temperature increase over 1 hour was also evaluated. Results Low-SAR regimens resulted in the lowest temperature increase (mean ± standard deviation, -0.03°C ± 0.20), normal regimens resulted in an intermediate increase (0.31°C ± 0.21), and high-SAR regimens resulted in the highest increase (0.56°C ± 0.20) (P < .0001). Mean temperature increase in the third trimester was 0.38°C ± 0.27, with no significant differences compared with the first (0.23°C ± 0.27) and second (0.25°C ± 0.32) trimesters (P = .07). The cumulative temperature increase over 1-hour imaging time with high SAR can reach 2.5°C. Conclusion In pregnant miniature pigs, the use of 3-T magnets for diagnostic MR imaging with normal SAR regimens does not lead to temperature increases above 1°C if imaging time is kept below 30 minutes. Longer imaging time, especially with high-SAR regimens, can lead to an increase of 2.5°C. (©) RSNA, 2015 Online supplemental material is available for this article.

Entities:  

Mesh:

Year:  2015        PMID: 26624974     DOI: 10.1148/radiol.2015151258

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

1.  Feasibility of whole-body diffusion-weighted MRI for detection of primary tumour, nodal and distant metastases in women with cancer during pregnancy: a pilot study.

Authors:  Sileny N Han; Frédéric Amant; Katrijn Michielsen; Frederik De Keyzer; Steffen Fieuws; Kristel Van Calsteren; Raphaëla C Dresen; Mina Mhallem Gziri; Vincent Vandecaveye
Journal:  Eur Radiol       Date:  2017-12-07       Impact factor: 5.315

2.  Individual variation in simulated fetal SAR assessed in multiple body models.

Authors:  Esra Abaci Turk; Filiz Yetisir; Elfar Adalsteinsson; Borjan Gagoski; Bastien Guerin; P Ellen Grant; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2019-10-18       Impact factor: 4.668

3.  Post-mortem whole-body magnetic resonance imaging of human fetuses: a comparison of 3-T vs. 1.5-T MR imaging with classical autopsy.

Authors:  Xin Kang; Mieke M Cannie; Owen J Arthurs; Valerie Segers; Catherine Fourneau; Elisa Bevilacqua; Teresa Cos Sanchez; Neil J Sebire; Jacques C Jani
Journal:  Eur Radiol       Date:  2017-01-23       Impact factor: 5.315

4.  PVR: Patch-to-Volume Reconstruction for Large Area Motion Correction of Fetal MRI.

Authors:  Amir Alansary; Martin Rajchl; Steven G McDonagh; Maria Murgasova; Mellisa Damodaram; David F A Lloyd; Alice Davidson; Mary Rutherford; Joseph V Hajnal; Daniel Rueckert; Bernhard Kainz
Journal:  IEEE Trans Med Imaging       Date:  2017-09-01       Impact factor: 10.048

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.