SYSTEM UPGRADE ON PHILIPS ALLURA FD20 ANGIOGRAPHY SYSTEMS: EFFECTS ON PATIENT SKIN DOSE AND STATIC IMAGE QUALITY.

Nick Ryckx1, Marta Sans-Merce2, Reto Meuli3, Jean-Baptiste Zerlauth3, Francis R Verdun4.   

Abstract

Fluoroscopically guided procedures might be highly irradiating for patients, possibly leading to skin injuries. In such a context, every effort should be done to lower patient exposure as much as possible. Moreover, patient dose reduction does not only benefit to the patient but also allows reducing staff exposure. In this framework, Philips Healthcare recently introduced a system upgrade for their angiography units, called 'AlluraClarity'. The authors performed air kerma rate measurements for all available fluoroscopy modes and air kerma per frame measurements for the digital subtraction angiography protocols, along with subjective spatial resolution and low-contrast detectability assessments using a standard QA phantom. Air kerma reductions ranging from 25.5 to 84.4 % were found, with no significant change in image quality when switching from a standard operating mode to an upgraded version. These results are confirmed by the comparison of actual patient exposures for similar procedures.
© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2015        PMID: 26622042     DOI: 10.1093/rpd/ncv484

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  Feasibility of ultra-low radiation dose digital subtraction angiography: Preliminary study in a simplified cerebral angiography phantom.

Authors:  Jun Young Maeng; Yunsun Song; Yu Sub Sung; Tae-Il Kim; Deok Hee Lee; Tae-Hyung Kim
Journal:  Interv Neuroradiol       Date:  2019-05-16       Impact factor: 1.610

2.  Radiation dose during endovascular aneurysm repair (EVAR): upgrade of an angiographic system from standard to Eco mode.

Authors:  Maria Antonella Ruffino; Marco Fronda; Andrea Discalzi; Paola Isoardi; Laura Bergamasco; Roberto Ropolo; Dorico Righi; Paolo Fonio
Journal:  Radiol Med       Date:  2018-07-23       Impact factor: 3.469

3.  Impact of dose reducing software on patient and staff temple dose during fluoroscopically guided pacemaker insertion, closure devices implantation and coronary angiography procedures.

Authors:  Kelly S Wilson-Stewart; Davide Fontanarosa; Eva Malacova; Jamie V Trapp
Journal:  Phys Eng Sci Med       Date:  2022-05-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.