Literature DB >> 26612249

The Contemporary Role of Masked Continuous Glucose Monitoring in a Real-Time World.

Ian Blumer1.   

Abstract

Real-time continuous glucose monitoring (RT-CGM) has, in the span of just a few years, established an essential role in the contemporary management of type 1 diabetes. Nonetheless, masked CGM retains an important place in the management of diabetes including assisting with hypoglycemia detection and avoidance, optimizing glycemic control, and acting as a teaching tool for people living with diabetes.
© 2015 Diabetes Technology Society.

Entities:  

Keywords:  continuous glucose monitoring; diabetes; masked; professional; real-time

Mesh:

Substances:

Year:  2016        PMID: 26612249      PMCID: PMC5038532          DOI: 10.1177/1932296815619182

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  22 in total

Review 1.  Review of hemoglobin A(1c) in the management of diabetes.

Authors:  Emily Jane Gallagher; Derek Le Roith; Zachary Bloomgarden
Journal:  J Diabetes       Date:  2009-01-27       Impact factor: 4.006

2.  Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring.

Authors:  Dorothee Deiss; Jan Bolinder; Jean-Pierre Riveline; Tadej Battelino; Emanuele Bosi; Nadia Tubiana-Rufi; David Kerr; Moshe Phillip
Journal:  Diabetes Care       Date:  2006-12       Impact factor: 19.112

3.  Statement by the American Association of Clinical Endocrinologists Consensus Panel on continuous glucose monitoring.

Authors:  Thomas C Blevins; Bruce W Bode; Satish K Garg; George Grunberger; Irl B Hirsch; Lois Jovanovič; Elizabeth Nardacci; Eric A Orzeck; Victor L Roberts; William V Tamborlane; Caitlin Rothermel
Journal:  Endocr Pract       Date:  2010 Sep-Oct       Impact factor: 3.443

4.  Continuous subcutaneous glucose monitoring in children with type 1 diabetes.

Authors:  H P Chase; L M Kim; S L Owen; T A MacKenzie; G J Klingensmith; R Murtfeldt; S K Garg
Journal:  Pediatrics       Date:  2001-02       Impact factor: 7.124

5.  A pilot study of the continuous glucose monitoring system: clinical decisions and glycemic control after its use in pediatric type 1 diabetic subjects.

Authors:  F R Kaufman; L C Gibson; M Halvorson; S Carpenter; L K Fisher; P Pitukcheewanont
Journal:  Diabetes Care       Date:  2001-12       Impact factor: 19.112

6.  Hypoglycemia in Type 2 Diabetes--More Common Than You Think: A Continuous Glucose Monitoring Study.

Authors:  Richa Redhu Gehlaut; Godwin Y Dogbey; Frank L Schwartz; Cynthia R Marling; Jay H Shubrook
Journal:  J Diabetes Sci Technol       Date:  2015-04-27

7.  Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry.

Authors:  Jenise C Wong; Nicole C Foster; David M Maahs; Dan Raghinaru; Richard M Bergenstal; Andrew J Ahmann; Anne L Peters; Bruce W Bode; Grazia Aleppo; Irl B Hirsch; Lora Kleis; H Peter Chase; Stephanie N DuBose; Kellee M Miller; Roy W Beck; Saleh Adi
Journal:  Diabetes Care       Date:  2014-07-10       Impact factor: 19.112

8.  Continuous glucose monitoring and intensive treatment of type 1 diabetes.

Authors:  William V Tamborlane; Roy W Beck; Bruce W Bode; Bruce Buckingham; H Peter Chase; Robert Clemons; Rosanna Fiallo-Scharer; Larry A Fox; Lisa K Gilliam; Irl B Hirsch; Elbert S Huang; Craig Kollman; Aaron J Kowalski; Lori Laffel; Jean M Lawrence; Joyce Lee; Nelly Mauras; Michael O'Grady; Katrina J Ruedy; Michael Tansey; Eva Tsalikian; Stuart Weinzimer; Darrell M Wilson; Howard Wolpert; Tim Wysocki; Dongyuan Xing
Journal:  N Engl J Med       Date:  2008-09-08       Impact factor: 91.245

9.  Effectiveness of continuous glucose monitoring in a clinical care environment: evidence from the Juvenile Diabetes Research Foundation continuous glucose monitoring (JDRF-CGM) trial.

Authors: 
Journal:  Diabetes Care       Date:  2009-10-16       Impact factor: 19.112

10.  Effectiveness of continuous glucose monitoring in pregnant women with diabetes: randomised clinical trial.

Authors:  Helen R Murphy; Gerry Rayman; Karen Lewis; Susan Kelly; Balroop Johal; Katherine Duffield; Duncan Fowler; Peter J Campbell; Rosemary C Temple
Journal:  BMJ       Date:  2008-09-25
View more
  3 in total

1.  Blood glucose monitoring (BGM) still matters for many: Associations of BGM frequency and glycemic control in youth with type 1 diabetes.

Authors:  Rebecca Ortiz La Banca; Yasaman Pirahanchi; Lisa K Volkening; Zijing Guo; Julia Cartaya; Lori M Laffel
Journal:  Prim Care Diabetes       Date:  2021-05-21       Impact factor: 2.567

Review 2.  Effectiveness and acceptability of continuous glucose monitoring for type 2 diabetes management: A narrative review.

Authors:  Pennie J Taylor; Campbell H Thompson; Grant D Brinkworth
Journal:  J Diabetes Investig       Date:  2018-03-01       Impact factor: 4.232

3.  Using Flash Continuous Glucose Monitoring in Primary Practice.

Authors:  Irl B Hirsch; Eugene E Wright
Journal:  Clin Diabetes       Date:  2019-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.