Literature DB >> 26594891

Acoustic wave biosensor for the detection of the breast and prostate cancer metastasis biomarker protein PTHrP.

Victor Crivianu-Gaita1, Mohamed Aamer1, Roy T Posaratnanathan1, Alexander Romaschin2, Michael Thompson3.   

Abstract

There are currently no biosensors that are able to reliably detect the process of cancer metastasis. We describe the first label-free real-time ultra-high frequency acoustic wave biosensor prototype capable of detecting the breast and prostate cancer metastasis biomarker, parathyroid hormone-related peptide (PTHrP). Two different linkers - 11-trichlorosilyl-undecanoic acid pentafluorophenyl ester (PFP) and S-(11-trichlorosilyl-undecanyl)-benzothiosulfonate (TUBTS) - were used to immobilize whole anti-PTHrP antibodies and Fab' fragments to surfaces as biorecognition elements. The biosensor surfaces were optimized using X-ray photoelectron spectroscopy (XPS) and the ultra-high frequency electromagnetic piezoelectric acoustic sensor (EMPAS). One optimized whole antibody-based surface (PFP/protein G'/whole antibodies/ethanolamine) and one optimized Fab' fragment-based surface (TUBTS/Fab' fragments) were tested as biosensors. It was determined that an in-line injection of bovine serum albumin prior to analyte injection yielded the most minimally fouling surfaces. Each surface was tested with no mass amplification and with sandwich-type secondary antibody mass amplification. The whole antibody-based mass-amplified biosensor yielded the lowest limit of detection (61 ng/mL), highest sensitivity, and a linear range from 61 ng/mL to 100 μg/mL. However, the Fab' fragment-based biosensor displayed better regenerability as a loss of ~20% of the initial analyte signal intensity was observed with each subsequent injection. The whole antibody-based biosensor was only capable of producing an analyte signal in the first injection.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Acoustic wave sensor; Antibodies; Biosensor; Cancer metastasis; Fab' fragments; Parathyroid hormone-related peptide

Mesh:

Substances:

Year:  2015        PMID: 26594891     DOI: 10.1016/j.bios.2015.11.031

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  A Visual FRET Immunofluorescent Biosensor for Ratiometric Parathyroid Hormone (1-84) Antigen Point-of-Care Detection.

Authors:  Yixin Nie; Jingting Li; Yang Liu; Qian Zhang; Qiang Ma
Journal:  J Fluoresc       Date:  2020-02-04       Impact factor: 2.217

2.  Effect of parathyroid hormone-related protein on intracellular calcium ion and cyclic adenosine monophosphate concentrations in cardiac fibroblasts.

Authors:  Ping Zhou; Qiong Xiao; Zhao-Ting Su; Lin Zhu; Fang-Xia Jin; Xuan-Yi Du
Journal:  J Int Med Res       Date:  2020-09       Impact factor: 1.671

Review 3.  Electrospun Nanofibers for Label-Free Sensor Applications.

Authors:  Nahal Aliheidari; Nojan Aliahmad; Mangilal Agarwal; Hamid Dalir
Journal:  Sensors (Basel)       Date:  2019-08-17       Impact factor: 3.576

4.  Electromagnetic Piezoelectric Acoustic Sensor Detection of Extracellular Vesicles through Interaction with Detached Vesicle Proteins.

Authors:  Loránd Románszki; Zoltán Varga; Judith Mihály; Zsófia Keresztes; Michael Thompson
Journal:  Biosensors (Basel)       Date:  2020-11-11

5.  A Quest for New Cancer Diagnosis, Prognosis and Prediction Biomarkers and Their Use in Biosensors Development.

Authors:  Eda G Ramirez-Valles; Alicia Rodríguez-Pulido; Marcelo Barraza-Salas; Isaac Martínez-Velis; Iván Meneses-Morales; Víctor M Ayala-García; Carlos A Alba-Fierro
Journal:  Technol Cancer Res Treat       Date:  2020 Jan-Dec
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.