| Literature DB >> 26589143 |
Tomasz Plonek1, Andrzej Dumanski2, Rafal Nowicki3, Wojciech Kustrzycki4.
Abstract
BACKGROUND: External wrapping is a surgical technique performed in patients with a dilated ascending aorta. The aim of this study is to present the mid-term results of wrapping of the dilated ascending aorta.Entities:
Mesh:
Year: 2015 PMID: 26589143 PMCID: PMC4654867 DOI: 10.1186/s13019-015-0371-1
Source DB: PubMed Journal: J Cardiothorac Surg ISSN: 1749-8090 Impact factor: 1.637
Patients characteristics
| Number of patients | 34 |
| Males (%) | 21 (62 %) |
| Age | 64.4 ± 10.8 years (median: 64.5, range: 29–82) |
| Preoperative diameter of the ascending aorta | 47.2 ± 4.5 mm (median: 46, range: 41–60 mm |
| Bicuspid aortic valve | 6 (17.6 %) |
| Euroscore 2 | 5.37 ± 5.11 % (median: 3.24 %, range: 0.96–25.52 %) |
| Type 2 diabetes | 8 (23.5 %) |
| Hypertension | 28 (82 %) |
Concomitant cardiac procedures performed in patients who underwent the wrapping procedure
| Concomitant cardiac surgery procedures | No. of patients |
|---|---|
| AVR | 18 (53 %) |
| Wrapping alone | 4 (12 %) |
| AVR + CABG | 4 (12 %) |
| AV reapir | 3 (9 %) |
| AV repair + CABG | 1 (3 %) |
| AVR, MVR (reoperation) | 1 (3 %) |
| AVR + CABG+ ASD closure | 1 (3 %) |
| MV repair | 1 (3 %) |
| MV repair + TV repair + CABG | 1 (3 %) |
AVR aortic valve replacement, CABG coronary artery bypass grafting, MVR mitral valve replacement, ASD atrial septal defect, MV mitral valve, TV tricuspid valve, AV aortic valve
Fig. 1A schematic presentation of wrapping of the dilated ascending aorta. a A longitudinally cut straight Dacron vascular prosthesis passed under the aorta. b A wrapped aorta
Intra and perioperative data
| Time of the procedure | 3 h 32′ ± 1 h 04′ (median: 3 h 15′, range: 1 h 25′–6 h 25′) |
| Aortic cross-clamping time | 55′ ± 31′ (median: 58′, range: 0′ – 1 h 48′) |
| Extracorporeal circulation time | 1 h 39′ ± 46′ (median:1 h 35′, range: 0′- 3 h 38′) |
| Inotropic support | 6 (17.6 %) |
| The mean postoperative drainage during the first 24 | 540 ml ± 400 ml (median:390 ml, range:190 ml – 1750 ml) |
| Blood transfusion | 12 (35 %) |