Literature DB >> 17257926

Long-term experience of girdling the ascending aorta with Dacron mesh as definitive treatment for aneurysmal dilation.

Oved Cohen1, Jonah Odim, David De la Zerda, Chidi Ukatu, Raj Vyas, Neil Vyas, Kathy Palatnik, Hillel Laks.   

Abstract

BACKGROUND: The management of the mildly to moderately dilated ascending aorta (3.5 to 4.9 cm) in cardiac surgery remains controversial. Therapeutic options have included radical aortic resection with synthetic graft substitution, external aortic reinforcement or wrap, with or without partial aortic wall excision, and a watch-and-wait approach. We reviewed our institutional experience with Dacron (DuPont, Wilmington, DE) mesh wrap support of dilated ascending aortas.
METHODS: During the last 20 years, 102 patients with aneurysmal dilatation of the ascending aorta underwent wrapping of the ascending aorta with a fine Dacron mesh from the ventricular-aortic junction to the origin of the innominate artery. For the last 10 years, the wrap was anchored to the aortic annulus with pledgeted sutures. Aortic diameters up to 6 cm, without focal areas of thinning, were wrapped. Aortic diameters exceeding 6 cm, or with focal thinning, underwent tailored aortic wall resection and wrapping. Primary end points of the study included mortality, aortic diameter growth, dissection or rupture, or both.
RESULTS: The mean age of the group was 54.7 +/- 19 years (range, 12 to 90 years). A single patient underwent aortic wrapping without cardiopulmonary bypass. Sixty-six patients (65%) required additional aortic valve surgery. Five patients (5%) had reinforcement of dilated sinuses with glutaraldehyde-treated pericardial patches combined with wrapping. Twenty-seven patients (26%) had combined coronary and valve surgery, and 2 patients had coronary revascularization alone. There was neither early nor hospital mortality. Among the 81 patients (79%) we were able to contact, 7 (7%) late deaths had occurred at 0.5, 1, 3, and 9 years after operation that were unrelated to aortic pathology. Various levels of follow-up were obtained in the 88 patients (86.2%). In 78 patients, echocardiograms, computed tomography angiograms, or magnetic resonance angiograms were obtained. In 2 of these patients, aneurysmal dilatation of the sinuses developed below the wrap and reoperation was required. No patient in whom the mesh wrap was anchored to the aortic annulus required reoperation. All 81 patients that were contacted by us and monitored by referring physicians were asymptomatic and free of problems related to the aorta. The mean (+/- SD) preoperative diameter of the ascending aorta was 49.2 +/- 7.8 mm (range, 35 to 87 mm), the postwrap intraoperative diameter was 32.9 +/- 3.4 mm (range, 20 to 40 mm), and the follow-up postoperative aortic diameter was 35.6 +/- 12.7 mm (range, 27 to 52 mm). The mean average change in the aortic diameter during the follow-up period was 2.6 +/- 14.8 mm (range, -7 to 22 mm), a mean of 8%. The mean follow-up period was 5.7 years (median, 4.77 years; range, 9 days to 21 years). There were no infections or other early complications related to the wrap.
CONCLUSIONS: Dacron mesh support of the moderately dilated aneurysmal ascending aorta, alone or in conjunction with coronary revascularization, aortic root surgery, or valvular operations, or both, is safe and durable. Dacron mesh is transparent and stretchable, permitting tight girdling of the aorta. These properties prevent hematoma formation, facilitate proximal vein graft anastomoses, and provide visualization and access to aortic suture lines. Finally, this technique retards further aortic dilation, altering the natural history of aortic aneurysms.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17257926     DOI: 10.1016/j.athoracsur.2006.10.086

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  18 in total

1.  Muslin-induced intracranial vasculopathic stenosis: a report of two cases.

Authors:  Daniel W Lee; Mandy J Binning; Victoria K Shanmugam; Richard H Schmidt; William T Couldwell; Maximilian Meyer; Thomas Cupps; Andrea Douglas; Kevin McGrail
Journal:  Clin Neurol Neurosurg       Date:  2011-09-21       Impact factor: 1.876

Review 2.  Personalized external aortic root support.

Authors:  Tom Treasure
Journal:  Tex Heart Inst J       Date:  2013

Review 3.  Wrapping of the ascending aorta revisited-is there any role left for conservative treatment of ascending aortic aneurysm?

Authors:  José María González-Santos; María Elena Arnáiz-García
Journal:  J Thorac Dis       Date:  2017-05       Impact factor: 2.895

4.  Vascular adaptation in the presence of external support - A modeling study.

Authors:  Abhay B Ramachandra; Marcos Latorre; Jason M Szafron; Alison L Marsden; Jay D Humphrey
Journal:  J Mech Behav Biomed Mater       Date:  2020-06-25

5.  External aortic root support: a histological and mechanical study in sheep.

Authors:  Peter Verbrugghe; Erik Verbeken; John Pepper; Tom Treasure; Bart Meyns; Bart Meuris; Paul Herijgers; Filip Rega
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-04-26

6.  Early impact of aortic wrapping on patients undergoing aortic valve replacement with mild to moderate ascending aorta dilatation.

Authors:  Keng-Leong Ang; Furqan Raheel; Amrita Bajaj; Andrzej Sosnowski; Manuel Galiñanes
Journal:  J Cardiothorac Surg       Date:  2010-08-06       Impact factor: 1.637

7.  Personalised external aortic root support (PEARS) to stabilise an aortic root aneurysm.

Authors:  John Pepper; Cemil Izgi; Tal J Golesworthy; Johanna J M Takkenberg; Tom Treasure
Journal:  Br J Cardiol       Date:  2020-07-28

8.  Wrapping of an Ascending Aortic Aneurysm with the Multiple Boot-Straps Technique in a Patient Undergoing Off-Pump Coronary Artery Bypass Grafting.

Authors:  Kwon Joong Na; Jun Sung Kim; Kay-Hyun Park; Cheong Lim
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2015-06-05

9.  Surgical treatment with wrapping of the moderately-dilated ascending aorta.

Authors:  Uğur Kaya; Abdurrahim Çolak; Münacettin Ceviz; Necip Becit; Hikmet Koçak
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2018-04-30       Impact factor: 0.332

10.  Biomechanical analysis of wrapping of the moderately dilated ascending aorta.

Authors:  Tomasz Plonek; Bartosz Rylski; Andrzej Dumanski; Przemyslaw Siedlaczek; Wojciech Kustrzycki
Journal:  J Cardiothorac Surg       Date:  2015-08-01       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.