Literature DB >> 26583362

Fat Suppression with Dixon Techniques in Musculoskeletal Magnetic Resonance Imaging: A Pictorial Review.

Henri Guerini1, Patrick Omoumi2, François Guichoux3, Valérie Vuillemin1, Gérard Morvan1, Marc Zins3, Fabrice Thevenin1, Jean Luc Drape1.   

Abstract

Dixon techniques are part of the methods used to suppress the signal of fat in MRI. They present many advantages compared with other fat suppression techniques including (1) the robustness of fat signal suppression, (2) the possibility to combine these techniques with all types of sequences (gradient echo, spin echo) and different weightings (T1-, T2-, proton density-, intermediate-weighted sequences), and (3) the availability of images both with and without fat suppression from one single acquisition. These advantages have opened many applications in musculoskeletal imaging. We first review the technical aspects of Dixon techniques including their advantages and disadvantages. We then illustrate their applications for the imaging of different body parts, as well as for tumors, neuromuscular disorders, and the imaging of metallic hardware. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2015        PMID: 26583362     DOI: 10.1055/s-0035-1565913

Source DB:  PubMed          Journal:  Semin Musculoskelet Radiol        ISSN: 1089-7860            Impact factor:   1.777


  22 in total

Review 1.  The Dixon technique for MRI of the bone marrow.

Authors:  Niels van Vucht; Rodney Santiago; Bianca Lottmann; Ian Pressney; Dorothee Harder; Adnan Sheikh; Asif Saifuddin
Journal:  Skeletal Radiol       Date:  2019-07-15       Impact factor: 2.199

2.  Fat suppression in magnetic resonance imaging of the head and neck region: is the two-point DIXON technique superior to spectral fat suppression?

Authors:  Christina M Wendl; Johannes Eiglsperger; Lena-Marie Dendl; Harald Brodoefel; Karl-Michael Schebesch; Christian Stroszczynski; Claudia Fellner
Journal:  Br J Radiol       Date:  2018-02-23       Impact factor: 3.039

Review 3.  Fat-containing soft-tissue masses in children.

Authors:  Elizabeth F Sheybani; Eric P Eutsler; Oscar M Navarro
Journal:  Pediatr Radiol       Date:  2016-11-19

4.  Assessment of facial autologous fat grafts using Dixon magnetic resonance imaging.

Authors:  Xueyin Liao; Xiaoqi Wang; Zhentan Xu; Shiwei Guo; Congmin Gu; Zhengyu Jin; Tong Su; Yu Chen; Huadan Xue; Mingyong Yang
Journal:  Quant Imaging Med Surg       Date:  2022-05

5.  Texture analysis using T1-weighted images for muscles in Charcot-Marie-Tooth disease patients and volunteers.

Authors:  Ji Hyun Lee; Young Cheol Yoon; Hyun Su Kim; Jae-Hun Kim; Byung-Ok Choi
Journal:  Eur Radiol       Date:  2020-10-30       Impact factor: 5.315

Review 6.  Imaging appearances of soft-tissue tumors of the pediatric foot: review of a 15-year experience at a tertiary pediatric hospital.

Authors:  Pablo Caro-Domínguez; Oscar M Navarro
Journal:  Pediatr Radiol       Date:  2017-10-26

7.  Clinical utility of fat-suppressed 3-dimensional controlled aliasing in parallel imaging results in higher acceleration sampling perfection with application optimized contrast using different flip angle evolutions MRI of the knee in adults.

Authors:  Seungho Lee; Guen Young Lee; Sujin Kim; Yong-Beom Park; Han-Jun Lee
Journal:  Br J Radiol       Date:  2020-06-24       Impact factor: 3.039

8.  Implementation of a sagittal T2-weighted DIXON turbo spin-echo sequence may shorten MRI acquisitions in the emergency setting of suspected spinal bleeding.

Authors:  Nico Sollmann; Charlotte Rüther; Simon Schön; Claus Zimmer; Thomas Baum; Jan S Kirschke
Journal:  Eur Radiol Exp       Date:  2021-05-12

Review 9.  Bone marrow magnetic resonance imaging: physiologic and pathologic findings that radiologist should know.

Authors:  Maria Grazia Chiarilli; Andrea Delli Pizzi; Domenico Mastrodicasa; Maria Pia Febo; Beatrice Cardinali; Bruno Consorte; Antonietta Cifaratti; Valentina Panara; Massimo Caulo; Giovanni Cannataro
Journal:  Radiol Med       Date:  2020-06-17       Impact factor: 6.313

10.  Comparing intramuscular adipose tissue on T1-weighted and two-point Dixon images.

Authors:  Madoka Ogawa; Akito Yoshiko; Noriko Tanaka; Teruhiko Koike; Yoshiharu Oshida; Hiroshi Akima
Journal:  PLoS One       Date:  2020-04-09       Impact factor: 3.240

View more