Literature DB >> 26581476

Hemodynamic Performance of a New Punched Stent Strut: A Numerical Study.

Yan Xue1, Xiao Liu1, Anqiang Sun1, Peng Zhang1, Yubo Fan1, Xiaoyan Deng1.   

Abstract

Local flow disturbance by arterial stent struts has been shown to play an important role in stent thrombosis. To reduce the local flow disturbance near a stent strut, we proposed a new concept of stent design with small holes in the stent struts. The present study evaluated the new design numerically by comparing it with the traditional stent in terms of local hemodynamic parameters such as flow velocity, flow recirculation area, time-averaged wall shear stress (TAWSS), oscillating shear index (OSI), and relative residence time (RRT). The results demonstrated that when compared with the traditional strut, the new design could significantly enhance flow velocity and reduce the flow recirculation zone in the vicinity of the strut. Moreover, the new design would significantly elevate TAWSS and remarkably reduce OSI and RRT along the host arterial wall. In conclusion, the new design of stent struts with punched holes is advantageous over the traditional one in the aspect of improving local hemodynamics, which may reduce thrombosis formation and promote re-endothelialization after stenting.
Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  Endothelialization; Hemodynamics; Punched stent strut; Stent thrombosis

Mesh:

Year:  2015        PMID: 26581476     DOI: 10.1111/aor.12638

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  7 in total

1.  A Research on Online Education Behavior and Strategy in University.

Authors:  Quan Deng
Journal:  Front Psychol       Date:  2022-04-25

2.  Hemodynamic Parameters Predict In-stent Thrombosis After Multibranched Endovascular Repair of Complex Abdominal Aortic Aneurysms: A Retrospective Study of Branched Stent-Graft Thrombosis.

Authors:  Ming-Yuan Liu; Yang Jiao; Junjun Liu; Simeng Zhang; Wei Li
Journal:  Front Cardiovasc Med       Date:  2021-04-23

3.  Comparative study of tapered versus conventional cylindrical balloon for stent implantation in stenotic tapered artery.

Authors:  Xiang Shen; Jiabao Jiang; Hongfei Zhu; Kaikai Lu; Pengfei Dong; Linxia Gu
Journal:  Artif Organs       Date:  2020-03-01       Impact factor: 2.663

4.  Improvement of hemodynamic performance using novel helical flow vena cava filter design.

Authors:  Ying Chen; Peng Zhang; Xiaoyan Deng; Yubo Fan; Yubin Xing; Ning Xing
Journal:  Sci Rep       Date:  2017-01-23       Impact factor: 4.379

5.  Numerical and Experimental Investigation of the Hemodynamic Performance of Bifurcated Stent Grafts with Various Torsion Angles.

Authors:  Ming Liu; Anqiang Sun; Xiaoyan Deng
Journal:  Sci Rep       Date:  2018-08-22       Impact factor: 4.379

6.  Hemodynamic performance within crossed stent grafts: computational and experimental study on the effect of cross position and angle.

Authors:  Ming Liu; Anqiang Sun; Xiaoyan Deng
Journal:  Biomed Eng Online       Date:  2018-06-19       Impact factor: 2.819

7.  Numerical and Experimental Investigation of Novel Blended Bifurcated Stent Grafts with Taper to Improve Hemodynamic Performance.

Authors:  Ming Liu; Zhenze Wang; Anqiang Sun; Xiaoyan Deng
Journal:  Comput Math Methods Med       Date:  2018-09-09       Impact factor: 2.238

  7 in total