Literature DB >> 26579935

Screen-printed carbon electrode-based electrochemical immunosensor for rapid detection of microalbuminuria.

Jang-Zern Tsai1, Ching-Jung Chen2, Kalpana Settu3, Yu-Feng Lin1, Chien-Lung Chen4, Jen-Tsai Liu5.   

Abstract

A urinary microalbumin test is used to detect early signs of kidney damage in people who have a risk of chronic kidney disease, such as those with diabetes or hypertension. In this study, we developed a screen-printed carbon electrode-based immunosensor for the detection of microalbumin in urine. Anti-human albumin antibodies were immobilized on the screen-printed sensor surface by the covalent immobilization method. Cyclic voltammetry (CV) and scanning electron microscopy with an energy dispersive spectroscopical (SEM-EDS) analysis demonstrated that the modification process was well performed. Chronoamperometric (CA) electrochemical measurement technique was employed for the quantitative detection of albumin. The electrochemical measurements performed with some possible interfering compounds normally present in urine (ascorbic acid, uric acid, glucose and creatinine samples) demonstrated a high specificity and selectivity of this immunosensor in albumin detection. Under optimum conditions, the immunosensor can detect urinary albumin in a wide linear range from 10 µg/ml to 300 µg/ml with a detection limit of 9.7 µg/ml. The excellent performance of this immunosensor was confirmed by analyzing microalbumin in urine samples; the results were in good agreement with those obtained by the standard immunoturbidimetric method. The biosensor proposed herein is easy to prepare and can be used for low-cost, rapid, and sensitive screening of microalbuminuria. This approach provides a promising platform for developing clinical point-of-care diagnostic applications.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chronoamperometry; Immunosensor; Microalbuminuria; Screen-printed carbon electrode

Mesh:

Substances:

Year:  2015        PMID: 26579935     DOI: 10.1016/j.bios.2015.11.002

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  A new SERS strategy for quantitative analysis of trace microalbuminuria based on immunorecognition and graphene oxide nanoribbon catalysis.

Authors:  Guiqing Wen; Qi Jing; Aihui Liang; Zhiliang Jiang
Journal:  Int J Nanomedicine       Date:  2018-10-05

2.  Cross-sectional retrospective analysis of clinical characteristics of chronic hepatitis B patients with oral antiviral treatment in eastern China.

Authors:  Jueqing Gu; Guodong Yu; Xiaoli Zhang; Shanyan Zhang; Huan Cai; Chanyuan Ye; Yida Yang; Dezhou Li; Zhaowei Tong; Huajiang Shen; Huazhong Chen; Feng Ding; Xijie Lai; Junyan Liu; Meiling Xu; Weiti Wu
Journal:  Virol J       Date:  2021-01-13       Impact factor: 4.099

3.  Development and validation of point-of-care testing of albuminuria for early screening of chronic kidney disease.

Authors:  Nuntanuj Vutthikraivit; Patcharakorn Kiatamornrak; Chatikorn Boonkrai; Trairak Pisitkun; Kittinan Komolpis; Songchan Puthong; Nuttha Lumlertgul; Sadudee Peerapornratana; Chusak Thanawattano; Somkanya Tungsanga; Kearkiat Praditpornsilpa; Kriang Tungsanga; Somchai Eiam-Ong; Nattachai Srisawat
Journal:  J Clin Lab Anal       Date:  2021-02-16       Impact factor: 2.352

4.  A sandwich-type bacteriophage-based amperometric biosensor for the detection of Shiga toxin-producing Escherichia coli serogroups in complex matrices.

Authors:  Irwin A Quintela; Vivian C H Wu
Journal:  RSC Adv       Date:  2020-09-30       Impact factor: 4.036

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.