A new SERS strategy for quantitative analysis of trace microalbuminuria based on immunorecognition and graphene oxide nanoribbon catalysis.

Guiqing Wen1,2, Qi Jing1,2, Aihui Liang1,2, Zhiliang Jiang1,2.   

Abstract

BACKGROUND: Microalbuminuria (mAlb) detection is essential for the diagnosis and prognosis of nephrotic patients and hypoproteinemia. In this article, we develop a new surface-enhanced Raman scattering (SERS) quantitative analysis method to detect mAlb in urine.
METHODS: Combined the mAlb immunoreaction with gold nanoreaction of graphene oxide nanoribbons (GONR)-HAuCl4-H2O2, and used Victoria blue B (VBB) as molecular probe with a SERS peak at 1,615 cm-1, a new SERS strategy for quantitative analysis of trace mAlb in urine was established.
RESULTS: The linear range of SERS quantitative analysis method is from 0.065 to 2.62 ng/mL, with a detection limit of 0.02 ng/mL. The SERS method was applied to analysis of mAlb in urine with good accuracy and reliability, the relative standard deviation is 0.49%-2.28% and the recovery is 96.9%-109.8%.
CONCLUSION: This study demonstrated that the new SERS quantitative analysis method is of high sensitivity, good selectivity and simplicity. It has been applied to analysis of mAlb in urine, with satisfactory results.

Entities:  

Keywords:  SERS; gold nanoreaction; graphene oxide nanoribbon; microalbumin immunoreaction; nanocatalysis

Mesh:

Substances:

Year:  2018        PMID: 30323597      PMCID: PMC6179722          DOI: 10.2147/IJN.S174765

Source DB:  PubMed          Journal:  Int J Nanomedicine        ISSN: 1176-9114


Introduction

Nanoparticles in solutions not only have novel surface nanoplasmon effect but also exhibit high catalytic activity as natural enzymes and mimic enzymes with stabilization and economic characteristics, and it has been used in different fields such as materials science, physics, chemistry, biology, and environmental science.1–4 In analytical chemistry, catalysis such as molecular reaction and nanoparticle reaction can be used to amplify signals to enhance sensitivity and have been utilized in absorption, fluorescence, resonance Rayleigh scattering (RRS), and surface-enhanced Raman scattering (SERS).5–8 A label-free DNAzyme-cleaving fluorescence method was developed for the determination of trace Pb2+ based on the catalysis of AuPd nanoalloy on the reduction of rhodamine 6G.5 Qu et al reported a colorimetric platform for visual detection of 0.1–10 ng/mL cancer biomarker based on intrinsic peroxidase activity of graphene oxide (GO).6 He et al prepared Au@Pt nanorods, which showed multiple enzyme properties and were used for spectrophotometric determination of 4.5×10−5–1×10−3 mol/L glucose (Glu).7 The nanocatalytic particle reaction is very interesting due to the novel surface plasmon resonance of Au and Ag nanoparticle that can be utilized to develop surface plasmon resonance absorption, RRS, and SERS methods with good features. A facile and sensitive peptide-modulating GONR catalytic nanoplasmon analytical platform was reported for human chorionic gonadotropin.8 Recently, non-metal nanoparticles are interesting to analysts. Carbon nanotube (CNT) is a one-dimensional nanomaterial with a complete molecular structure at the nanoscale and is a good precursor to prepare water-soluble and stable GONR. CNTs have been used in the field of chemical sensing for its excellent physical and chemical properties. Ye et al9 produced MnO2/CNT composites with KMnO4 oxidizing multi-walled carbon nanotubes (MWCNTs) to have strong electrocatalytic oxidation properties to detect H2O2 as low as 0.1 µM. Qu et al10 investigated the catalytic activity of the peroxidase mimetics of single-walled carbon nanotubes (SWCNTs) and achieved the Cu2+ visual detection. Cui et al11 prepared helical CNTs by hydrothermal-hydrogen reduction and investigated its catalytic activity as peroxidase mimetics. An electrochemical biosensor for H2O2 was developed with a linear range (LR) of 0.5–115 µmol/L. Zhang et al12 formed composite nanomaterials by combining positively charged gold nanoparticles (AuNPs) with SWCNTs and found that the material had a strong peroxide mimetic enzyme activity, thereby established a labeled DNA hybridization colorimetric detection method. However, CNTs are not water soluble that limits its application, and GONRs overcome this problem and provide the conditions for its analytical application without organic solvents. Zhang13 developed a bioelectrochemical sensor based on GONR modified for rapid detection of L/D-amino acids (AA) with an LR of 0.25–1.25 mmol/L and a detection limit (DL) of 100 and 60 µmol/L, respectively. Dong et al14 used GONR to build biosensors to detect 5–100 µmol/L adenosine triphosphate. Zhu et al15 developed a novel MWCNTs@GONR core-shell heterostructure and a sensitive electrochemical sensor for the detection of 8–500 nmol/L polycyclic aromatic amines. So far, no SERS was used to track GONR-catalytic AuNP reaction that can be regulated by mAlb immunoreaction for assay of trace mAlb. SERS is a kind of selective and sensitive molecular spectral technique, which has attracted much attention in analysis, biology, and medical treatment.16 Generally, SERS signal depends upon a number of factors. However, the substrate-adsorbed molecular probe can greatly amplify the signals and it is linear to the SERS signal at some certain conditions,17,18 and an SERS method can be developed for the detection of the molecular probe. Javier and Ronei17 studied a paper-based portable SERS method for the detection of uric acid, with an LR of 0–3.5 mmol/L and a DL of 0.11 mmol/L. Wang et al18 used the catalytic activity of GO to catalyze the H2O2-HAuCl4 system, and then ligands regulated the use of SERS to detect human chorionic gonadotropin, and Hg2+ in concentrations ranging from 0.25 to 10 ng/mL, 0.25–10 nmol/L, was tested on samples which showed good recovery. Frost et al19 developed a SERS sensor based on citrate-functionalized AuNP for 50–1,000 ng/L Pb2+. Gao et al20 immobilized the peptide nucleic acid with the target DNA on a slide, and 1.0×10−10–1.0×10−6 mol/L DNA can be detected by SERS. Another type of SERS method was reported according to the change in the concentration of nanosol substrate in the analytical system. For example, a facile aptamer-regulating gold nanoplasmonic SERS detection strategy was proposed for trace lead ions based on the nanocatalytic particle reaction and nanoplasmon. Immunoassay is a kind of analytical method based on the specific reaction of antigen and antibody (Ab). It has the characteristics of high sensitivity and specificity and has been used in the fields of disease diagnosis, food safety, and environmental protection.21 In recent years, highly sensitive SERS technology combining with specific immuno-reaction has been favored to analysts.22–26 Ma et al26 reported an SERS quantitative analysis method for trace human chorionic gonadotropin using a label-free Victoria blue B (VBB; C33H32ClN3) as probe in the aggregated immunonanogold sol substrate. She et al27 combined Hg2+ with the double-labeled Raman active 4-mercaptobenzoic acid and gold nanoparticles monoclonal antibodies on immunochromatographic test strips to obtain SERS immunoprobe to detect as low as 0.45 pg/mL of Hg2+. To our best knowledge, there are no SERS quantitative analysis methods for trace mAlb without preparation of immunonanoprobe and label-free SERS molecular probes, based on the coupling of GONR-catalytic nanoreaction with immunoreaction. Albumin is a normal protein in the blood, but there is only a small amount of albumin in the urine under physiological conditions (<20 mg/L), because it is usually reabsorbed by glomerular filtration and renal proximal tubule.28 Urinary albumin that is normally in the range of 20–200 mg/L is called as microalbuminuria (mAlb).29 So it should be noted when the mAlb concentration is sustained excess, because it shows that nephrotic patients have a large number of albumin leakage and may be hypoproteinemia. And the development of kidney disease is possibly irreversible. Therefore, proteinuria is an important clinical symptom of nephropathy, and the control of mAlb concentration has a great clinical reference value to determine the degree of disease and prognosis. The rise of mAlb concentration is a reflection of early glomerular lesions sensitive indicators, especially in chronic renal injury such as diabetic nephropathy, hypertension, and systemic lupus erythematosus, and its detection is clinically significant.30 At present, mAlb detection methods are mainly electrochemical immunosensor,31 radioimmunoassay,32 ELISA,33 turbidity analysis,34 high-performance liquid chromatography, and so on.35 In this paper, a new gold nanoplasmon molecular spectral platform was established for rapid and selective quantitative detection of trace mAlb based on the immunoreaction-regulation of the GONR catalytic AuNP reaction.

Experimental

Instruments and reagents

A DXR smart Raman spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) with laser wavelength of 633 nm, power of 2.5 mW, slit of 50 µm, and acquisition time of 5 seconds; Hitachi F-7000 fluorescence spectrophotometer (Hitachi Ltd, Tokyo, Japan); TU-1901 dual-beam UV-visible spectrophotometer (Beijing Puxi General Equipment Limited Company, Beijing, China); and constant temperature water bath were used. A 97 mmol/L HAuCl4 solution, 10 µmol/L VBB, 10 mol/L H2O2 solution, 3.4 mmoL/L trisodium citrate, 10 mmol/L AgNO3, 0.1 moL/L Glu, 10 mg/mL mAlb, and 5 mg/mL mAlb Ab were prepared. 98% H2SO4, KMnO4, GO (Nanjing Xianfeng Nanomaterial Technology Co. Ltd, Nanjing, China) and MWCNTs (No XFM12; Nanjing Xianfeng Nanomaterial Technology Co. Ltd) were used. The used reagents were of analytical pure grade, and the experimental water was the secondary distilled water.

Preparation of GONR

GONR was prepared by chemical melting MWCNTs. 50 mg of MWCNT powder was added into a 50 mL round bottom flask which containing 10 mL of concentrated H2SO4 and the reaction took place for 1 hour. Then, a certain content (100, 200, 250, 300, 400, 500, 750, or 1,000 mg) of KMnO4 was added and mixed well before the solution being heated for 2 hours in a 60°C water bath. The product was added into 200 mL ice water containing 5 mL of 30% H2O2 before being dispersed for 10 minutes by unltrasonic and centrifuged at 7,000 rpm for 10 minutes. The supernatant was obtained which contained 230 µg/mL GONR. Thus, GONR of different oxidation degrees (GONR1, GONR2, GONR3, GONR4, GONR5, GONR6, GONR7, and GONR8) were prepared by changing the amount of KMnO4. The supernatant was neutralized to pH 7 with 50 mmol/L NaOH and diluted to the desired concentration before use.

Procedure

A suitable concentration of mAlb, 50 µL of 60 ng/mL mAlb and 60 µL of 47.6 ng/mL GONR were added into a 5 mL test tube successively. After mixing well for 10 minutes, 100 µL of 2.9 mmol/L HAuCl4 and 30 µL of 0.1 mol/L H2O2 solution were added and diluted to the volume of 1.5 mL with water. The mixture was heated in a 60°C water bath for 10 minutes, then cooled with ice water to terminate the reaction, and 50 µL 10 µmol/L VBB was added. The SERS intensity (I1,615 cm−1) and the blank without mAlb (I1,615 cm−1)0 was measured to calculate the value of ∆I1,615 cm−1 = I1,615 cm−1 − (I1,615 cm−1)0. DL was three times of SD which obtained from parallel determination of blank samples (n=10).

Results and discussion

Principles of analysis

The catalytic reaction of H2O2–HAuCl4 increased with the increase of GONR concentration. The more the nanoparticle catalyst is added, the higher SERS intensity is obtained. In the system with Ab, the protein macromolecules bound to GONR and inhibited its catalytic activity. When the mAlb antigen was added, it specifically bound to the Ab, and the nanoenzyme GONR was released. With the increase of the amount of mAlb, the SERS peak increased due to the restoration of GONR catalysis. The mAlb concentration and SERS peak were of a linear relationship, which could be established to detect mAlb by SERS technique (Figure 1).
Figure 1

Principles of SERS immunoanalysis of mAlb coupled with GONR catalysis.

Abbreviations: SERS, surface-enhanced Raman scattering; GONR, graphene oxide nanoribbon; VBB, Victoria blue B; Ab, antibody; mAlb, microalbumin; MWCNT, multi-walled carbon nanotube.

SERS spectra

Under the normal pressure and temperature, the reaction of H2O2 and HAuCl4 was slow. GONR had strong catalytic effect on the reaction to form AuNPs that exhibited five strong SERS peaks in the presence of VBB molecular probes. The characteristic peaks of the above system include 1,164 (C–C stretching), 1,199 (C–H bending), 1,362 (ring stretching), 1,393 (C–N stretching), and 1,615 (C=N and N–H stretching). After adding Ab, it could inhibit the catalytic activity of GONR by binding to the surface of GONR catalyst, and the SERS signal linearly decreased (Figure S1). After the addition of mAlb, the stable immunocomplexes formed to release free GONR, and the SERS signal enhanced due to the catalysis recovering. With the increase of the amount of mAlb, the catalysis increased to cause the SERS intensity to gradually increase for the GONR6 (Figure 2), GONR3 (Figure S2A), and GO (Figure S2B) analytical systems. Results showed that the GONR6 catalysis, using the slope of I1,615 cm−1 vs concentration of GONR, was the strongest, and the GONR6 system for detection of mAlb was the most sensitive. The blank spectra of pure GONRs, antibodies, and micro-albumin of the test concentrations were recorded respectively, and the results showed that all the blank spectra were very weak and that meant that the SERS peaks mainly attributed to the product of the nanocatalytic reaction. The SERS peak at 1,615 cm−1 was chosen for mAlb assay because it was the most sensitive and the intensity ∆I1,615 cm−1 = I1,615 cm−1 − (I1,615 cm−1)0 was linear to the mAlb concentration.
Figure 2

SERS spectra of GONR6-Ab-mAlb-HAuCl4-H2O2.

Notes: a: 0.21 mmol/L HAuCl4 + 0.006% H2O2 + 2.34 ng/mL GONR6 + 0.1 mmol/L HCl + 3.3×10−7 mol/L VBB + 3.3 ng/mL Ab; b: a + 0.26 ng/mL mAlb; c: a + 0.665 ng/mL mAlb; d: a + 1.33 ng/mL mAlb; e: a + 2 ng/mL mAlb; f: a + 2.62 ng/mL mAlb.

Abbreviations: SERS, surface-enhanced Raman scattering; GONR, graphene oxide nanoribbon; Ab, antibody; mAlb, microalbumin; VBB, Victoria blue B.

RRS and UV-Vis spectra

According to the procedure, the RRS spectra were obtained by synchronous scanning with the fluorescence spectrophotometer under the conditions of voltage =450 V, excited slit = emission slit =5 nm, emission filter =1% T attenuator, and λex − λem = Δλ =0. The results showed that GONR had a strong resonance scattering peak at about 310 nm. With the increase of mAlb concentration, more GONR was released and more AuNPs were produced which lead to the linear increase in the RRS peak (Figure S3). In the GONR systems, GONR6 was the most sensitive, and a simple and sensitive RRS method could also be developed to detect the concentrations of mAlb with an LR of 0.08–3.18 ng/mL (Figure 3A). Compared to the SERS method, the RRS method was less sensitive, but the procedure of RRS method is simpler than the SERS method without VBB. The TU-1901 dual-beam UV-Vis spectrophotometer was used to measure the absorbance of the system, and the results (Figure 3B, Figure S4) showed that GONR6 system had an obvious absorption peak at about 580 nm. With the increase of mAlb concentration, the Abs peak gradually increased.
Figure 3

RRS and absorption spectra of GONR6-Ab-mAlb-HAuCl4-H2O2.

Notes: (A) a: 0.21 mmol/L HAuCl4 + 0.006% H2O2 + 2.34 ng/mL GONR6 + 3.3×10−7 mol/L VBB + 3.3 ng/mL Ab; b: a + 0.53 ng/mL mAlb; c: a + 1.06 ng/mL mAlb; d: a + 2.12 ng/mL mAlb; e: a + 2.65 ng/mL mAlb. (B) a: 0.21 mmol/L HAuCl4 + 0.006% H2O2 + 2.34 ng/mL GONR6 + 3.3×10−7 mol/L VBB + 3.3 ng/mL Ab; b: a + 0.53 ng/mL mAlb; c: a + 1.59 ng/mL mAlb; d: a + 2.12 ng/mL mAlb; e: a + 2.65 ng/mL mAlb.

Abbreviations: RRS, Rayleigh scattering; GONR, graphene oxide nanoribbon; Ab, antibody; mAlb, microalbumin; VBB, Victoria blue B.

Catalysis and inhibition

Under the experimental conditions, MWCNT has no catalysis because it is insoluble in water. GONR and GO catalyzed H2O2–HAuCl4 reaction to generate nanoparticles (Figure 4). As the oxidation–reduction pair of Au3+/Au has a low potential (1.401 V),36 it is difficult to form AuNPs from the Au3+ ions in one step. The reaction is easier to proceed with the addition of GONR as a catalyst. Since GONR has rich surface electrons, the electrons are transferred from the GONR to the Au3+ ions and converted into Au+ ions. The oxidation–reduction pair of Au+/Au has higher potential (1.692 V) and AuNPs are easier to be obtained. The catalytic activities of eight kinds of different GONR were compared mainly by three parameters (LR, linear equation, and coefficient), and the inhibition of Ab was studied (Table 1). The results showed that the linear equation of GONR6 system had the highest slope. This shows that GONR6 had the strongest catalysis because MWCNT had the most suitable oxidation degree and the carboxyl numbers were the most suitable. When the Ab was added into the system, the Ab would attach to the GONR surface, blocking the contact between the catalyst and H2O2/HAuCl4 to inhibit its catalytic activity. With the increase of Ab, the system catalytic effect reduced and the SERS intensity weakened. The system reduction ∆I1,615 cm−1 has a linear relationship with Ab concentration, and the inhibition of Ab-GONR6 system was the strongest because the slope is biggest.
Figure 4

Mechanism of GONR catalyzed H2O2 reduction of HAuCl4 to produce nanogold particles.

Abbreviation: GONR, graphene oxide nanoribbon.

Table 1

Comparison of catalysis and Ab inhibition by SERS method

Catalysis systemLinear rangeLinear equationCoefficient
GONR10.91–3.06 ng/mL GONR1∆I1,615 cm−1= 120.01C + 4.50.9321
GONR20.91–3.06 ng/mL GONR2∆I1,615 cm−1 = 198.4C − 32.10.9643
GONR30.91–3.06 ng/mL GONR3∆I1,615 cm−1= 346.0C − 139.20.9537
GONR40.91–3.06 ng/mL GONR4∆I1,615 cm−1= 412.7C − 90.90.9293
GONR50.91–3.06 ng/mL GONR5∆I1,615 cm−1= 437.6C − 137.30.9551
GONR60.91–3.06 ng/mL GONR6∆I1,615 cm−1= 782.5C − 271.50.9458
GONR70.91–3.06 ng/mL GONR7∆I1,615 cm−1= 428.9C − 71.70.9689
GONR80.91–3.06 ng/mL GONR8∆I1,615 cm−1= 275.3C − 52.00.9644
Ab-GONR10.26–5.3 ng/mL Ab∆I= 60.8C + 61.80.904
Ab-GONR20.26–5.3 ng/mL Ab∆I1,615 cm−1= 94.5C + 85.30.9356
Ab-GONR30.26–5.3 ng/mL Ab∆I1,615 cm−1= 161.0C + 60.70.9562
Ab-GONR40.26–5.3 ng/mL Ab∆I= 174.7C + 33.20.9764
Ab-GONR50.26–5.3 ng/mL Ab∆I1,615 cm−1= 197C + 153.00.929
Ab-GONR60.26–5.3 ng/mL Ab∆I1,615 cm−1= 363.5C − 511.80.9776
Ab-GONR70.26–5.3 ng/mL Ab∆I1,615 cm−1= 206.8C + 160.50.9339
Ab-GONR80.26–5.3 ng/mL Ab∆I1,615 cm−1= 130.2C + 113.20.9204

Abbreviations: Ab, antibody; GONR, graphene oxide nanoribbon; SERS, surface-enhanced Raman scattering.

Laser scattering

The size distribution of nanoparticles of mAlb-Ab-GONR6-H2O2-HAuCl4 system was detected (Figure 5). The results showed that the average particle size of the non-mAlb system was 240±12 nm (Figure 5A). With the increase of mAlb concentration, the average particle sizes of the nanoparticles were 190.1±9.5 and 170.5±8.5 nm, respectively (Figure 5B and C), and the particle size was generally uniform.
Figure 5

Distribution of size of the nanoparticles.

Notes: a: 0.21 mmol/L HAuCl4 + 0.006% H2O2 + 1.84 ng/mL GONR6 + 3.3 ng/mL Ab; b: a + 1.33 ng/mL mAlb; c: a + 3.2 ng/mL mAlb.

Abbreviations: Ab, antibody; GONR, graphene oxide nanoribbon; mAlb, microalbumin.

Transmission electron microscopy (TEM)

In addition to laser scattering, TEM was also used to record the shape and size of the particles. According to the procedure, TEM of the different systems were recorded (Figure 6). The catalytic activity of the blank system without mAlb was weak, so the reaction of H2O2–HAuCl4 was slow and there were rare big particles in the system (Figure 6A). When mAlb was added, it reacted specifically with the Ab to form free GONR6 and more nanoparticles were produced due to the restoration of GONR6 catalysis (Figure 6B). For the lower oxidation degree of GONR2, the catalytic effect was weaker and the AuNPs produced by the reaction were less. GONR2 with low oxidation degree contained a small amount of nanobelts. GONR6 solution with higher oxidation degree showed good catalytic activity, and the reaction resulted in more nanoparticles with comparatively more uniform particle size.
Figure 6

TEM of the analytical system.

Notes: (A) 0.21 mmol/L HAuCl4 + 0.006% H2O2 + 1.84 ng/mL GONR6 + 0.1 mmol/L HCl + 3.3×10−7 mol/L VBB + 3.3 ng/mL Ab; (B) A + 2.62 ng/mL mAlb.

Abbreviations: TEM, transmission electron microscopy; GONR, graphene oxide nanoribbon; VBB, Victoria blue B.

Optimization of analytical conditions

The analytical conditions of HAuCl4-H2O2-GONR6-Ab-mAlb system were optimized (Figure S5). The results showed that ∆I1,615 cm−1 reached the maximum at 1.84 ng/mL of GONR6. When the concentration of Ab was 3.3 ng/mL, ∆I1,615 cm−1 reached the maximum. When the concentration of H2O2 was 2 mmol/L, ∆I1,615 cm−1 was maximum. When the HAuCl4 concentration was 0.152 mmol/L, ∆I1,615 cm−1 reached the maximum, and so 0.152 mmoL/L HAuCl4 was selected. The HCl concentration was optimized too, and 0.11 mmol/L HCl was selected. Under the chosen conditions at 60°C water bath, the reaction time of 10 minutes was good. The probe concentration was optimized, and 0.33 µmol/L VBB was selected.

Working curve

According to the procedure, the working curves of different SERS systems were drawn. For the GONR6 system, which was the most sensitive, the concentration of mAlb in the LR of 0.065–2.6 ng/mL has a good linear relationship with the ∆I1,615 cm−1, with the DL of 0.02 ng/mL. By comparing three analytical techniques of SERS/RRS/Abs (Tables 2, S1, and S2), the SERS method of GONR6 system had the highest slope (914.19), which shows that it has the highest sensitivity because of being strongest catalytic amplification, so it was selected to measure mAlb. Compared with the reported mAlb analysis method (Table S3),31–35,37–39 this method is highly sensitive and easy to operate, and it is one of the best methods for detecting mAlb.
Table 2

Analysis feature of the SERS system

GONR systemLR (ng/mL)Linear equationCoefficientDL (ng/mL)
GONR10.33–6.6∆I1,615 cm−1= 107.6C + 159.00.90160.1
GONR20.33–3.2∆I1,615 cm−1= 108.2C + 40.90.95860.1
GONR30.33–3.2∆I1,615 cm−1= 380.6C + 70.40.98050.1
GONR40.33–3.2∆I1,615 cm−1= 276.6C + 80.00.96990.1
GONR50.24–3.2∆I1,615 cm−1= 398.6C − 55.70.98210.1
GONR60.065–2.6∆I1,615 cm−1= 914.2C + 20.00.98740.02
GONR70.13–2.6∆I1,615 cm−1= 558.4C + 109.00.93170.04
GONR80.13–2.6∆I1,615 cm−1= 311.1C + 71.10.9780.04

Abbreviations: LR, linear range; DL, detection limit; GONR, graphene oxide nanoribbon.

Interference effects

The effects of coexisting substances in HAuCl4-H2O2-GONR6-Ab-mAlb system on the determination of 10 ng/mL mAlb were investigated. The results showed that 100 times of K+, Zn2+, Ca2+, S2O32−, SO32−, NO2−, CO32−, tyrosine, lysine, and phenylalanine; 50 times of Cu2+, Mg2+, tryptophan, and glutamic acid; and 10 times of Fe3+ and cysteine did not interfere with the determination in the relative error range of no more than ±10.0%, and the method has good selectivity.

Sample analysis

Five fresh urine samples including two from diabetic patients were obtained from the Yanshan District People’s Hospital of Guilin City, and the samples were detected according to the experimental procedures. Then, different standard mAlb solution was added and detected. The results (Table S4) showed that the relative SD was between 0.49% and 2.28%, and the recoveries were between 96.9% and 109.8%.

Conclusion

The as-prepared GONR has strong catalytic effect on HAuCl4–H2O2 nanoreaction to form AuNPs with nanoplasmon effect such as SERS, RRS, and Abs, and Ab could adsorbed on the surface of GONR, which blocks the redox electron transfer of HAuCl4 and H2O2 to inhibit its catalytic action. Experiments show that mAlb enhances the signals of Ab-GONR-HAuCl4-H2O2 nanoanalytical system. Based on this principle, an immunoregulation gold nanoplasmon method for the rapid detection of mAlb has been established, with simplicity, high selectivity, and sensitivity.
  29 in total

Review 1.  Multiplex in vitro detection using SERS.

Authors:  Stacey Laing; Kirsten Gracie; Karen Faulds
Journal:  Chem Soc Rev       Date:  2015-12-21       Impact factor: 54.564

2.  A competitive immunoassay for ultrasensitive detection of Hg(2+) in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering.

Authors:  Pei She; Yanxin Chu; Chunwei Liu; Xun Guo; Kang Zhao; Jianguo Li; Haijing Du; Xiang Zhang; Hong Wang; Anping Deng
Journal:  Anal Chim Acta       Date:  2015-12-18       Impact factor: 6.558

3.  Directed assembly of carbon nanotubes at liquid-liquid interfaces: nanoscale conveyors for interfacial biocatalysis.

Authors:  Prashanth Asuri; Sandeep S Karajanagi; Jonathan S Dordick; Ravi S Kane
Journal:  J Am Chem Soc       Date:  2006-02-01       Impact factor: 15.419

Review 4.  Surface-enhanced Raman scattering (SERS) and surface-enhanced resonance Raman scattering (SERRS): a review of applications.

Authors:  Graeme McNay; David Eustace; W Ewen Smith; Karen Faulds; Duncan Graham
Journal:  Appl Spectrosc       Date:  2011-08       Impact factor: 2.388

5.  Simple sequential injection analysis system for rapid determination of microalbuminuria.

Authors:  Wanida Laiwattanapaisal; Usakorn Kunanuvat; Wichabhorn Intharachuti; Chakorn Chinvongamorn; Supot Hannongbua; Orawon Chailapakul
Journal:  Talanta       Date:  2009-02-20       Impact factor: 6.057

6.  Colorimetric platform for visual detection of cancer biomarker based on intrinsic peroxidase activity of graphene oxide.

Authors:  Fengli Qu; Ting Li; Minghui Yang
Journal:  Biosens Bioelectron       Date:  2011-03-21       Impact factor: 10.618

7.  Improved competitive enzyme-linked immunoassay (ELISA) for albuminuria.

Authors:  R G Neuman; M P Cohen
Journal:  Clin Chim Acta       Date:  1989-02-22       Impact factor: 3.786

Review 8.  Redox-active radical scavenging nanomaterials.

Authors:  Ajay Karakoti; Sanjay Singh; Janet M Dowding; Sudipta Seal; William T Self
Journal:  Chem Soc Rev       Date:  2010-08-17       Impact factor: 54.564

9.  SERS spectral study of HAuCl4-cysteine nanocatalytic reaction and its application for detection of heparin sodium with label-free VB4r molecular probe.

Authors:  Xiaoliang Wang; Caina Jiang; Yanna Qin; Yutao Peng; Guiqing Wen; Aihui Liang; Zhiliang Jiang
Journal:  Sci Rep       Date:  2017-04-05       Impact factor: 4.379

Review 10.  Microalbuminuria: definition, detection, and clinical significance.

Authors:  Robert D Toto
Journal:  J Clin Hypertens (Greenwich)       Date:  2004-11       Impact factor: 3.738

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.