Comparison of positive end-expiratory pressure-induced increase in central venous pressure and passive leg raising to predict fluid responsiveness in patients with atrial fibrillation.

N Kim1, J-K Shim1, H G Choi2, M K Kim1, J Y Kim3, Y-L Kwak4.   

Abstract

BACKGROUND: Positive end-expiratory pressure (PEEP)-induced increase in central venous pressure (CVP) has been suggested to be a robust indicator of fluid responsiveness, with heart rhythm having minimal influence. We compared the ability of PEEP-induced changes in CVP with passive leg raising (PLR)-induced changes in stroke volume index (SVI) in patients with atrial fibrillation after valvular heart surgery.
METHODS: In 43 patients with atrial fibrillation after cardiac surgery, PEEP was increased from 0 to 10 cm H2O for 5 min and changes in CVP were assessed. After returning the PEEP to 0 cm H2O, PLR was performed for 5 min and changes in SVI were recorded. Finally, 300 ml of colloid was infused and haemodynamic variables were assessed 5 min after completion of a fluid challenge. Fluid responsiveness was defined as an increase in SVI ≥10% measured by a pulmonary artery catheter.
RESULTS: Fifteen (35%) patients were fluid responders. There was no correlation between PEEP-induced increases in CVP and changes in SVI after a fluid challenge (β coefficient -0.052, P=0.740), whereas changes in SVI during PLR showed a significant correlation (β coefficient 0.713, P<0.001). The area under the receiver operating characteristic curve of the PEEP-induced increase in CVP and changes in SVI during PLR for fluid responsiveness was 0.556 [95% confidence interval (CI) 0.358-0.753, P=0.549) and 0.771 (95% CI 0.619-0.924, P=0.004), respectively.
CONCLUSIONS: A PEEP-induced increase in CVP did not predict fluid responsiveness in patients with atrial fibrillation after cardiac surgery, but increases in SVI during PLR seem to be a valid predictor of fluid responsiveness in this subset of patients.
© The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Keywords:  atrial fibrillation; central venous pressure; fluid responsiveness; passive leg raising; positive end-expiratory pressure

Mesh:

Year:  2015        PMID: 26577035     DOI: 10.1093/bja/aev359

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  8 in total

Review 1.  Physiology-guided management of hemodynamics in acute respiratory distress syndrome.

Authors:  Gustavo A Cortes-Puentes; Richard A Oeckler; John J Marini
Journal:  Ann Transl Med       Date:  2018-09

2.  Positive end-expiratory pressure-induced increase in external jugular venous pressure does not predict fluid responsiveness in laparoscopic prostatectomy.

Authors:  Min Hur; Seokha Yoo; Jung-Yoon Choi; Sun-Kyung Park; Dhong Eun Jung; Won Ho Kim; Jin-Tae Kim; Jae-Hyon Bahk
Journal:  J Anesth       Date:  2018-02-27       Impact factor: 2.078

Review 3.  Prediction of fluid responsiveness in ventilated patients.

Authors:  Mathieu Jozwiak; Xavier Monnet; Jean-Louis Teboul
Journal:  Ann Transl Med       Date:  2018-09

Review 4.  Pearls and pitfalls in comprehensive critical care echocardiography.

Authors:  Sam Orde; Michel Slama; Andrew Hilton; Konstantin Yastrebov; Anthony McLean
Journal:  Crit Care       Date:  2017-11-17       Impact factor: 9.097

5.  The diagnostic accuracy of inferior vena cava respiratory variation in predicting volume responsiveness in patients under different breathing status following abdominal surgery.

Authors:  Qian Ma; Xueduo Shi; Jingjing Ji; Luning Chen; Yali Tian; Jing Hao; Bingbing Li
Journal:  BMC Anesthesiol       Date:  2022-03-08       Impact factor: 2.217

6.  Respiratory changes of the inferior vena cava diameter predict fluid responsiveness in spontaneously breathing patients with cardiac arrhythmias.

Authors:  Perrine Bortolotti; Delphine Colling; Vincent Colas; Benoit Voisin; Florent Dewavrin; Julien Poissy; Patrick Girardie; Maeva Kyheng; Fabienne Saulnier; Raphael Favory; Sebastien Preau
Journal:  Ann Intensive Care       Date:  2018-08-02       Impact factor: 6.925

7.  Can the behavior of blood pressure after elevation of the positive end-expiratory pressure help to determine the fluid responsiveness status in patients with septic shock?

Authors:  Samia Cherem; Veviani Fernandes; Karine Duarte Zambonato; Glauco Adrieno Westphal
Journal:  Rev Bras Ter Intensiva       Date:  2020 Jul-Sep

8.  Portal Vein Pulsatility as a Dynamic Marker of Venous Congestion Following Cardiac Surgery: An Interventional Study Using Positive End-Expiratory Pressure.

Authors:  Pierre Huette; Pierre-Grégoire Guinot; Guillaume Haye; Mouhamed Djahoum Moussa; Christophe Beyls; Mathieu Guilbart; Lucie Martineau; Hervé Dupont; Yazine Mahjoub; Osama Abou-Arab
Journal:  J Clin Med       Date:  2021-12-12       Impact factor: 4.241