| Literature DB >> 26576249 |
Ji-Young Yoo1, Hyung-In Yoon1, Ji-Man Park2, Eun-Jin Park1.
Abstract
PURPOSE: The purpose of this study was to evaluate the bond strength of composite resin on the fracture surface of metal-ceramic depending on the repair systems and surface roughening methods.Entities:
Keywords: Composite resin; Porcelain repair; Shear bond strength; Tribochemical silica coating
Year: 2015 PMID: 26576249 PMCID: PMC4644774 DOI: 10.4047/jap.2015.7.5.343
Source DB: PubMed Journal: J Adv Prosthodont ISSN: 2005-7806 Impact factor: 1.904
Information of the materials used in the study
| Component | Chemical composition | Lot No. | |
|---|---|---|---|
| Intraoral Repair Kit | Porcelain Etchant | 4% Hydrofluoric acid | 1300002868 |
| Porcelain Primer | Silane with ethanol and acetone | 1300005107 | |
| Opaquer Catalyst | Bis-GMA, benzoyl peroxide | 1000010727 | |
| Opaquer Base Universal | Bis-GMA, urethane dimethacrylate | 1000010727 | |
| Metal primer Adhesive (Bisco) | Z-Prime Plus | Biphenyl dimethacrylate, HEMA, ethanol | 1000003112 |
| ONE-STEP Plus | Biphenyl dimethacrylate with acetone, HEMA | 1400006379 | |
| Composite (Bisco) | AEITE All-Purpose Body | Ethoxylated Bis-GMA, TEGDMA | 1300003757 |
| CoJet Sand system | CoJet Sand | 30 µm aluminum oxide modified silica | 439147 |
| ESPE-Sil | 3-methacryloxypropyltrimethoxysilane with ethyl alcohol | 225505 | |
| Opaque (3M ESPE) | Sinfony opaque liquid | Dicyclopentyldimethylene diacrylate, MMA | 159673 |
| Sinfony opaque powder | Silane treated quartz, titanium dioxide | ||
| Adhesive (3M ESPE) | Adper Single Bond 2 | Bisphenol diglycidyl ether dimethacrylate | N407020 |
| 2-hydroxyehtyl methacrylate with ethyl alcohol | |||
| Composite (3M ESPE) | Filtek Z250 | Bis-GMA, TEGDMA | N528688 |
Fig. 1Specimen of resin composite bonded to substrate aligned in universal testing machine for measurement of shear bond strength (A: apparatus of shear load, C: resin composite, P: poly-methyl methacrylate mold with porcelain or metal substrates).
Mean shear bond strength values and statistical analysis results of the specimens tested in the study
| Type of core material | Group | Mean (MPa) | SD |
|---|---|---|---|
| Porcelain | DP (Repair system I) | 16.28Aa | 4.50 |
| SP (Repair system I) | 25.85Ba | 3.51 | |
| CP (Repair system II) | 16.23Ac | 2.16 | |
| Metal (Ni-Cr alloy) | DM (Repair system I) | 3.12Cb | 1.16 |
| SM (Repair system I) | 6.56Cb | 2.88 | |
| CM (Repair system II) | 13.81Dc | 3.45 |
Values followed by identical uppercase letters present no statistical differences between groups with identical core materials. Lowercase letters with the same subscript show no significant differences between groups with identical repair methods. DP and DM group: porcelain and metal specimens treated with repair system I (Intraoral Repair Kit) after diamond bur roughening, respectively; SP and SM group: porcelain and metal specimens treated with repair system I (Intraoral Repair Kit) after airborne-particle abrasion; CP and CM group: porcelain and metal specimens treated with repair system II (CoJet Intraoal Repair system).