Literature DB >> 26573896

Expandable proximal femoral nail versus gamma proximal femoral nail for the treatment of AO/OTA 31A1-3 fractures.

Drexler Michael1, Warschawski Yaniv2, Frenkel Rutenberg Tal3, G Kessler Evan4, Amar Eyal2, Snir Nimrod2, Rath Ehud2, Eizenberg Gilad2, Steinberg L Ely2.   

Abstract

INTRODUCTION: The gamma-proximal femoral nail (GPFN) and the expandable proximal femoral nail (EPFN) are two commonly used intramedullary devices for the treatment of AO 31A1-3 proximal femur fractures. The aim of this study was to compare outcomes and complication rates in patients treated by both devices. PATIENTS AND METHODS: A total of 299 patients (149 in the GPFN group and 150 in the EPFN group, average age 83.6 years) were treated for AO 31A1-3 proximal femur fractures in our institution between July 2008 and February 2013. Time from presentation to surgery, level of experience of the surgeon, operative time, amount of blood loss and number of blood transfusions were recorded. Postoperative radiological variables, including peg/screw location, tip to apex distance and orthopaedic complications, as, malunion, nonunion, surgical wound infection rates, cutouts, periprosthetic fractures and the incidence of non-orthopaedic complications. Functional results were estimated using the modified Harris Hip Score, and quality of life was queried by the SF-36 questionnaire.
RESULTS: The GPFN and the EPFN fixation methods were similar in terms of functional outcomes, complication rates and quality of life assessments. More patients (107 vs. 73) from the GPFN group were operated within 48 h from presentation (44.8 h vs. 49.9 h for the EPFN group, p=0.351), and their surgery duration and hospitalisation were significantly longer (18.5 days vs. 26 days, respectively, p<0.001). The GPFN patients were frequently operated by junior surgeons: 90% (135) while 50.6% (76) of the EPFN operations were performed by senior doctors. Other intraoperative measures were similar between groups. Cutout was the most common complication affecting 6.7% of the GPFN group and 3.3% of the EPFN group (p=0.182).
CONCLUSIONS: Good clinical outcomes and low complication rates in the GPFN and the EPFN groups indicate essentially equivalent safety and reliability on the part of both devices for the treatment of proximal femoral fractures.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cutout; EPFN; GPFN; Intramedullary nail; Proximal femoral fracture

Mesh:

Year:  2015        PMID: 26573896     DOI: 10.1016/j.injury.2015.10.013

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  1 in total

1.  Nailing unstable pertrochanteric fractures: does size matters?

Authors:  Rafael Luque Pérez; Pablo Checa Betegón; María Galán-Olleros; Camila Arvinius; Jose Valle-Cruz; Fernando Marco
Journal:  Arch Orthop Trauma Surg       Date:  2020-11-04       Impact factor: 3.067

  1 in total