Literature DB >> 26561914

Automated measurement of CT noise in patient images with a novel structure coherence feature.

Minsoo Chun1, Young Hun Choi, Jong Hyo Kim.   

Abstract

While the assessment of CT noise constitutes an important task for the optimization of scan protocols in clinical routine, the majority of noise measurements in practice still rely on manual operation, hence limiting their efficiency and reliability. This study presents an algorithm for the automated measurement of CT noise in patient images with a novel structure coherence feature. The proposed algorithm consists of a four-step procedure including subcutaneous fat tissue selection, the calculation of structure coherence feature, the determination of homogeneous ROIs, and the estimation of the average noise level. In an evaluation with 94 CT scans (16 517 images) of pediatric and adult patients along with the participation of two radiologists, ROIs were placed on a homogeneous fat region at 99.46% accuracy, and the agreement of the automated noise measurements with the radiologists' reference noise measurements (PCC  =  0.86) was substantially higher than the within and between-rater agreements of noise measurements (PCCwithin  =  0.75, PCCbetween  =  0.70). In addition, the absolute noise level measurements matched closely the theoretical noise levels generated by a reduced-dose simulation technique. Our proposed algorithm has the potential to be used for examining the appropriateness of radiation dose and the image quality of CT protocols for research purposes as well as clinical routine.

Entities:  

Mesh:

Year:  2015        PMID: 26561914     DOI: 10.1088/0031-9155/60/23/9107

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT.

Authors:  André Euler; Markus M Obmann; Zsolt Szucs-Farkas; Achille Mileto; Caroline Zaehringer; Anna L Falkowski; David J Winkel; Daniele Marin; Bram Stieltjes; Bernhard Krauss; Sebastian T Schindera
Journal:  Eur Radiol       Date:  2018-02-19       Impact factor: 5.315

2.  Development of deep learning-assisted overscan decision algorithm in low-dose chest CT: Application to lung cancer screening in Korean National CT accreditation program.

Authors:  Sihwan Kim; Woo Kyoung Jeong; Jin Hwa Choi; Jong Hyo Kim; Minsoo Chun
Journal:  PLoS One       Date:  2022-09-29       Impact factor: 3.752

3.  Fully automated image quality evaluation on patient CT: Multi-vendor and multi-reconstruction study.

Authors:  Minsoo Chun; Jin Hwa Choi; Sihwan Kim; Chulkyun Ahn; Jong Hyo Kim
Journal:  PLoS One       Date:  2022-07-20       Impact factor: 3.752

4.  Simulated Radiation Dose Reduction in Whole-Body CT on a 3rd Generation Dual-Source Scanner: An Intraindividual Comparison.

Authors:  Andreas S Brendlin; Moritz T Winkelmann; Phuong Linh Do; Vincent Schwarze; Felix Peisen; Haidara Almansour; Malte N Bongers; Christoph P Artzner; Jakob Weiss; Jong Hyo Kim; Ahmed E Othman; Saif Afat
Journal:  Diagnostics (Basel)       Date:  2021-01-13

5.  An Improved Method of Automated Noise Measurement System in CT Images.

Authors:  Choirul Anam; Idam Arif; Freddy Haryanto; Fauzia P Lestari; Rena Widita; Wahyu S Budi; Heri Sutanto; Kusworo Adi; Toshioh Fujibuchi; Geoff Dougherty
Journal:  J Biomed Phys Eng       Date:  2021-04-01

6.  An algorithm for automated modulation transfer function measurement using an edge of a PMMA phantom: Impact of field of view on spatial resolution of CT images.

Authors:  Choirul Anam; Toshioh Fujibuchi; Wahyu Setia Budi; Freddy Haryanto; Geoff Dougherty
Journal:  J Appl Clin Med Phys       Date:  2018-10-19       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.