Literature DB >> 26556184

A simple microfluidic aggregation analyzer for the specific, sensitive and multiplexed quantification of proteins in a serum environment.

Nitin K Rajan1, Sukumar Rajauria2, Tyler Ray3, Sumita Pennathur3, Andrew N Cleland4.   

Abstract

Portable and low-cost platforms for protein biomarker detection are highly sought after for point of care applications. We demonstrate a simple microfluidic device for the rapid, electrically-based detection of proteins in serum. Our aggregation analyzer relies on detecting the protein-induced aggregation of sub-micron particles, using a one-step procedure followed by a fast, particle-by-particle measurement with a very high count rate. This enables the rapid and precise quantification of C-Reactive protein levels, within the clinically relevant range, using unprocessed human serum and a disposable microfluidic device; no optics are involved in the implementation. Due to the single particle detection format and the use of microfluidics, only a small volume of serum (~50 nL) is needed to complete the analysis. The method can be easily extended to multiplexed biomarker detection by combining an assay using differently sized particles, each targeting a separate protein. We illustrate this by using two sizes of latex beads and demonstrating the simultaneous detection of two different proteins in a serum environment with minimal cross-interference. This confirms that our aggregation analyzer platform provides a simple and straightforward method for multiplexed biomarker detection in a low cost, portable design.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Lab-on-chip; Label-free biosensing; Microfluidics; Particle immunoassay; Resistive pulse sensing

Mesh:

Substances:

Year:  2015        PMID: 26556184     DOI: 10.1016/j.bios.2015.10.093

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Development and Comparison of Two Immuno-disaggregation Based Bioassays for Cell Secretome Analysis.

Authors:  Pawan Kc; Fan Liu; Jiang Zhe; Ge Zhang
Journal:  Theranostics       Date:  2018-01-01       Impact factor: 11.556

2.  An open-source software analysis package for Microspheres with Ratiometric Barcode Lanthanide Encoding (MRBLEs).

Authors:  Björn Harink; Huy Nguyen; Kurt Thorn; Polly Fordyce
Journal:  PLoS One       Date:  2019-03-22       Impact factor: 3.240

3.  A Low-Cost Micro-Volume Nephelometric System for Quantitative Immunoagglutination Assays.

Authors:  Qiqi Sun; Wei Zheng; Chao Lin; Dongxuan Shen
Journal:  Sensors (Basel)       Date:  2019-10-09       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.