Literature DB >> 26556008

Reliability of Pentacam HR Thickness Maps of the Entire Cornea in Normal, Post-Laser In Situ Keratomileusis, and Keratoconus Eyes.

Zhe Xu1, Mei Peng1, Jun Jiang1, Chun Yang1, Weigen Zhu1, Fan Lu1, Meixiao Shen2.   

Abstract

PURPOSE: To measure the repeatability and reproducibility of Pentacam HR system thickness maps for the entire cornea in normal, post-laser in situ keratomileusis (post-LASIK), and keratoconus (KC) eyes.
DESIGN: Reliability study.
METHODS: Sixty normal subjects (60 eyes), 30 post-LASIK subjects (60 eyes), and 14 KC patients (27 eyes) were imaged with the Pentacam HR system by 2 well-trained operators. For pachymetry the cornea was divided into 4 zones: a central zone (2-mm diameter) and concentric pericentral zone (2-5 mm), transitional zone (5-7 mm), and peripheral zone (7-10 mm). The 3 concentric zones were subdivided into 8 sectors. Intraobserver repeatability and interobserver reproducibility of entire corneal thickness maps were tested by the repeatability and reproducibility coefficients, intraclass correlation coefficients, coefficient of variation, and 95% limits of agreement.
RESULTS: From central to peripheral zones, the precision of corneal thickness measurements became gradually smaller. Central zone repeatability and reproducibility were the best in the normal, post-LASIK, and KC groups. The peripheral superior sectors showed poorer repeatability and reproducibility for all subjects. The intraobserver repeatability and interobserver reproducibility for all zones were ≤19.3 μm, ≤22.1 μm, and ≤20.7 μm, in the normal, post-LASIK, and KC groups, respectively. The intraobserver and interobserver coefficients of variation for all zones were ≤1.3%, ≤1.6%, and ≤1.6% for all 3 groups.
CONCLUSIONS: Pentacam HR system pachymetry of the entire cornea provided good precision in normal, post-LASIK, and KC corneas. Thickness measurements in the peripheral cornea should be interpreted with caution in abnormal corneas after surgery or with diseases.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 26556008     DOI: 10.1016/j.ajo.2015.11.008

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  6 in total

1.  Agreement Between Predicted and Actual Measured Ablation Depth After FS-LASIK Using Different Rotating Scheimpflug Cameras and OCT.

Authors:  Hao Chen; Ziqian Wang; Kunke Li; Yiran Wang; Xin Li; Lan Du; Meimin Lin; Giacomo Savini; Qinmei Wang; Ayong Yu; Sisi Chen
Journal:  Front Med (Lausanne)       Date:  2022-05-19

2.  Repeatability of corneal elevation maps in keratoconus patients using the tomography matching method.

Authors:  YaRu Zheng; LiFang Huang; YiPing Zhao; JunJie Wang; XiaoBo Zheng; Wei Huang; Brendan Geraghty; QinMei Wang; ShiHao Chen; FangJun Bao; Ahmed Elsheikh
Journal:  Sci Rep       Date:  2017-12-12       Impact factor: 4.379

3.  Evaluating the repeatability of corneal elevation through calculating the misalignment between Successive topography measurements during the follow up of LASIK.

Authors:  XiaoBo Zheng; WeiHua Yang; LiFang Huang; JunJie Wang; Si Cao; Brendan Geraghty; YiPing Zhao; QinMei Wang; FangJun Bao; Ahmed Elsheikh
Journal:  Sci Rep       Date:  2017-06-09       Impact factor: 4.379

4.  The precision and agreement of corneal thickness and keratometry measurements with SS-OCT versus Scheimpflug imaging.

Authors:  Yune Zhao; Ding Chen; Giacomo Savini; Qing Wang; Hongfang Zhang; Yili Jin; Benhao Song; Rui Ning; Jinhai Huang; Chenyang Mei
Journal:  Eye Vis (Lond)       Date:  2020-06-09

5.  The repeatability of corneal topography measurements in severe Dry Eye disease.

Authors:  Soner Guven
Journal:  BMC Ophthalmol       Date:  2022-07-15       Impact factor: 2.086

6.  Comparison of radius of anterior lens surface curvature measurements in vivo using the anterior segment optical coherence tomography and Scheimpflug imaging.

Authors:  Zhenzhen Liu; Xiaoting Ruan; Wei Wang; Juzi Liu; Yijing Meng; Xiaoxun Gu; Jun Fu; Lixia Luo; Yizhi Liu
Journal:  Ann Transl Med       Date:  2020-03