Literature DB >> 26547741

Screening for atrial fibrillation with automated blood pressure measurement: Research evidence and practice recommendations.

Willem J Verberk1, Stefano Omboni2, Anastasios Kollias3, George S Stergiou3.   

Abstract

Several guidelines recommend opportunistic screening for atrial fibrillation (AF) in subjects aged ≥ 65 years using pulse palpation during routine blood pressure (BP) measurement. However, this method has limited diagnostic accuracy. A specific algorithm for AF detection during automated BP measurement was developed and implemented in a novel oscillometric device (Microlife WatchBP Home-A). In 2013, the UK National Institute for Health and Care Excellence (NICE) recommended this device for AF screening during routine office BP measurement in primary care in subjects ≥ 65 years. A review and meta-analysis of the evidence on the diagnostic accuracy of this algorithm were performed. Six studies (n=2332) investigated the accuracy of AF detection using the Microlife BP monitor and estimated a pooled sensitivity at 0.98 (95% CI 0.95, 1.00) and specificity 0.92 (0.88, 0.96). Analysis of 4 studies (n=1126) showed more readings to improve specificity (from 0.86 to 0.91) and sensitivity (from 0.97 to 0.99). Taking 3 sequential readings with at least 2 detecting AF gave the highest diagnostic accuracy. A single study (n=139) of paroxysmal AF screening with home BP monitoring (3316 days) showed sensitivity 99% and specificity 93%. Another study (n=46) of AF screening with 24h ambulatory BP monitoring showed that AF detected in >15% of all readings has high probability of AF diagnosis requiring confirmation by 24h electrocardiography. AF detection with routine automated BP measurement is a reliable screening tool in the elderly, which requires confirmation by electrocardiography. Paroxysmal AF might also be detected by routine automated home or ambulatory BP monitoring.
Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

Entities:  

Keywords:  Arrhythmia; Blood pressure monitoring; Clinic; Home blood pressure; Self-measurement; Stroke

Mesh:

Year:  2015        PMID: 26547741     DOI: 10.1016/j.ijcard.2015.10.182

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  18 in total

1.  Detection of atrial fibrillation in primary care with radial pulse palpation, electronic blood pressure measurement and handheld single-lead electrocardiography: a diagnostic accuracy study.

Authors:  Nicole Verbiest-van Gurp; Steven B Uittenbogaart; Wim A M Lucassen; Petra M G Erkens; J André Knottnerus; Bjorn Winkens; Henri E J H Stoffers; Henk C P M van Weert
Journal:  BMJ Open       Date:  2022-06-29       Impact factor: 3.006

2.  Home blood pressure monitoring in the 21st century.

Authors:  George S Stergiou; Kazuomi Kario; Anastasios Kollias; Richard J McManus; Takayoshi Ohkubo; Gianfranco Parati; Yutaka Imai
Journal:  J Clin Hypertens (Greenwich)       Date:  2018-07       Impact factor: 3.738

3.  Blood Pressure in Patients With Atrial Fibrillation: Part 1--Measurement.

Authors:  Debbie L Cohen; Raymond R Townsend
Journal:  J Clin Hypertens (Greenwich)       Date:  2016-08-20       Impact factor: 3.738

4.  Diagnostic performance of an automatic blood pressure measurement device, Microlife WatchBP Home A, for atrial fibrillation screening in a real-world primary care setting.

Authors:  Pak-Hei Chan; Chun-Ka Wong; Louise Pun; Yu-Fai Wong; Michelle Man-Ying Wong; Daniel Wai-Sing Chu; Chung-Wah Siu
Journal:  BMJ Open       Date:  2017-06-15       Impact factor: 2.692

5.  Atrial Fibrillation Screening in Nonmetropolitan Areas Using a Telehealth Surveillance System With an Embedded Cloud-Computing Algorithm: Prospective Pilot Study.

Authors:  Juey-Jen Hwang; Yi-Lwun Ho; Ying-Hsien Chen; Chi-Sheng Hung; Ching-Chang Huang; Yu-Chien Hung
Journal:  JMIR Mhealth Uhealth       Date:  2017-09-26       Impact factor: 4.773

Review 6.  Recommendations for home blood pressure monitoring in Latin American countries: A Latin American Society of Hypertension position paper.

Authors:  Raúl Villar; Ramiro A Sánchez; José Boggia; Ernesto Peñaherrera; Jesús Lopez; Weimar Sebba Barroso; Eduardo Barbosa; Leonardo Cobos; Rafael Hernández Hernández; José Andrés Octavio; José Z Parra Carrillo; Agustín J Ramírez; Gianfranco Parati
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-02-12       Impact factor: 3.738

7.  Blood pressure measurement in special populations and circumstances.

Authors:  George S Stergiou; Eamon Dolan; Anastasios Kollias; Neil R Poulter; Andrew Shennan; Jan A Staessen; Zhen-Yu Zhang; Michael A Weber
Journal:  J Clin Hypertens (Greenwich)       Date:  2018-07       Impact factor: 3.738

Review 8.  New Technologies for Detection and Management of Atrial Fibrillation.

Authors:  Adel Khalifa Sultan Hamad
Journal:  J Saudi Heart Assoc       Date:  2021-06-25

9.  Opportunistic detection of atrial fibrillation using blood pressure monitors: a systematic review.

Authors:  Sarah A Kane; James R Blake; Frank J McArdle; Philip Langley; Andrew J Sims
Journal:  Open Heart       Date:  2016-04-12

10.  Opportunistic screening of atrial fibrillation by automatic blood pressure measurement in the community.

Authors:  Stefano Omboni; Willem J Verberk
Journal:  BMJ Open       Date:  2016-04-12       Impact factor: 2.692

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.