Literature DB >> 26543296

A comparison of 2D and 3D digital image correlation for a membrane under inflation.

Barbara J Murienne1, Thao D Nguyen1.   

Abstract

Three-dimensional (3D) digital image correlation (DIC) is becoming widely used to characterize the behavior of structures undergoing 3D deformations. However, the use of 3D-DIC can be challenging under certain conditions, such as high magnification, and therefore small depth of field, or a highly controlled environment with limited access for two-angled cameras. The purpose of this study is to compare 2D-DIC and 3D-DIC for the same inflation experiment and evaluate whether 2D-DIC can be used when conditions discourage the use of a stereo-vision system. A latex membrane was inflated vertically to 5.41 kPa (reference pressure), then to 7.87 kPa (deformed pressure). A two-camera stereo-vision system acquired top-down images of the membrane, while a single camera system simultaneously recorded images of the membrane in profile. 2D-DIC and 3D-DIC were used to calculate horizontal (in the membrane plane) and vertical (out of the membrane plane) displacements, and meridional strain. Under static conditions, the baseline uncertainty in horizontal displacement and strain were smaller for 3D-DIC than 2D-DIC. However, the opposite was observed for the vertical displacement, for which 2D-DIC had a smaller baseline uncertainty. The baseline absolute error in vertical displacement and strain were similar for both DIC methods, but it was larger for 2D-DIC than 3D-DIC for the horizontal displacement. Under inflation, the variability in the measurements were larger than under static conditions for both DIC methods. 2D-DIC showed a smaller variability in displacements than 3D-DIC, especially for the vertical displacement, but a similar strain uncertainty. The absolute difference in the average displacements and strain between 3D-DIC and 2D-DIC were in the range of the 3D-DIC variability. Those findings suggest that 2D-DIC might be used as an alternative to 3D-DIC to study the inflation response of materials under certain conditions.

Entities:  

Keywords:  2D profile measurements; 3D full-field measurements; Digital image correlation; Inflation; Mechanical testing

Year:  2015        PMID: 26543296      PMCID: PMC4629498          DOI: 10.1016/j.optlaseng.2015.07.013

Source DB:  PubMed          Journal:  Opt Lasers Eng        ISSN: 0143-8166            Impact factor:   4.836


  15 in total

1.  Error evaluation technique for three-dimensional digital image correlation.

Authors:  Zhenxing Hu; Huimin Xie; Jian Lu; Huaixi Wang; Jianguo Zhu
Journal:  Appl Opt       Date:  2011-11-20       Impact factor: 1.980

2.  Three-dimensional digital image correlation technique using single high-speed camera for measuring large out-of-plane displacements at high framing rates.

Authors:  Mark Pankow; Brian Justusson; Anthony M Waas
Journal:  Appl Opt       Date:  2010-06-10       Impact factor: 1.980

3.  The inflation response of the posterior bovine sclera.

Authors:  Kristin M Myers; Baptiste Coudrillier; Brad L Boyce; Thao D Nguyen
Journal:  Acta Biomater       Date:  2010-06-15       Impact factor: 8.947

4.  Strain field measurements on mouse carotid arteries using microscopic three-dimensional digital image correlation.

Authors:  M A Sutton; X Ke; S M Lessner; M Goldbach; M Yost; F Zhao; H W Schreier
Journal:  J Biomed Mater Res A       Date:  2008-01       Impact factor: 4.396

5.  Determination of three-dimensional displacement using two-dimensional digital image correlation.

Authors:  Chenggen Quan; Cho Jui Tay; Wei Sun; Xiaoyuan He
Journal:  Appl Opt       Date:  2008-02-01       Impact factor: 1.980

6.  Minimal preconditioning effects observed for inflation tests of planar tissues.

Authors:  Theresa K Tonge; Barbara J Murienne; Baptiste Coudrillier; Stephen Alexander; William Rothkopf; Thao D Nguyen
Journal:  J Biomech Eng       Date:  2013-11       Impact factor: 2.097

7.  Full-field optical deformation measurement in biomechanics: digital speckle pattern interferometry and 3D digital image correlation applied to bird beaks.

Authors:  Joris Soons; Pascal Lava; Dimitri Debruyne; Joris Dirckx
Journal:  J Mech Behav Biomed Mater       Date:  2012-05-18

8.  Full-field bulge test for planar anisotropic tissues: part I--experimental methods applied to human skin tissue.

Authors:  Theresa K Tonge; Lorre S Atlan; Liming M Voo; Thao D Nguyen
Journal:  Acta Biomater       Date:  2012-12-20       Impact factor: 8.947

9.  Biomechanics of the human posterior sclera: age- and glaucoma-related changes measured using inflation testing.

Authors:  Baptiste Coudrillier; Jing Tian; Stephen Alexander; Kristin M Myers; Harry A Quigley; Thao D Nguyen
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-04-02       Impact factor: 4.799

10.  The in vitro inflation response of mouse sclera.

Authors:  Kristin M Myers; Frances E Cone; Harry A Quigley; Scott Gelman; Mary E Pease; Thao D Nguyen
Journal:  Exp Eye Res       Date:  2010-09-22       Impact factor: 3.467

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.