Literature DB >> 23026697

Full-field optical deformation measurement in biomechanics: digital speckle pattern interferometry and 3D digital image correlation applied to bird beaks.

Joris Soons1, Pascal Lava, Dimitri Debruyne, Joris Dirckx.   

Abstract

In this paper two easy-to-use optical setups for the validation of biomechanical finite element (FE) models are presented. First, we show an easy-to-build Michelson digital speckle pattern interferometer (DSPI) setup, yielding the out-of-plane displacement. We also introduce three-dimensional digital image correlation (3D-DIC), a stereo photogrammetric technique. Both techniques are non-contact and full field, but they differ in nature and have different magnitudes of sensitivity. In this paper we successfully apply both techniques to validate a multi-layered FE model of a small bird beak, a strong but very light biological composite. DSPI can measure very small deformations, with potentially high signal-to-noise ratios. Its high sensitivity, however, results in high stability requirements and makes it hard to use it outside an optical laboratory and on living samples. In addition, large loads have to be divided into small incremental load steps to avoid phase unwrapping errors and speckle de-correlation. 3D-DIC needs much larger displacements, but automatically yields the strains. It is more flexible, does not have stability requirements, and can easily be used as an optical strain gage.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23026697     DOI: 10.1016/j.jmbbm.2012.05.004

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  5 in total

1.  A comparison of 2D and 3D digital image correlation for a membrane under inflation.

Authors:  Barbara J Murienne; Thao D Nguyen
Journal:  Opt Lasers Eng       Date:  2015-08-15       Impact factor: 4.836

2.  Minimal preconditioning effects observed for inflation tests of planar tissues.

Authors:  Theresa K Tonge; Barbara J Murienne; Baptiste Coudrillier; Stephen Alexander; William Rothkopf; Thao D Nguyen
Journal:  J Biomech Eng       Date:  2013-11       Impact factor: 2.097

3.  Finite-element modelling reveals force modulation of jaw adductors in stag beetles.

Authors:  J Goyens; J Soons; P Aerts; J Dirckx
Journal:  J R Soc Interface       Date:  2014-12-06       Impact factor: 4.118

Review 4.  Biomechanical assessment in models of glaucomatous optic neuropathy.

Authors:  Thao D Nguyen; C Ross Ethier
Journal:  Exp Eye Res       Date:  2015-06-24       Impact factor: 3.467

5.  Validation experiments on finite element models of an ostrich (Struthio camelus) cranium.

Authors:  Andrew R Cuff; Jen A Bright; Emily J Rayfield
Journal:  PeerJ       Date:  2015-10-13       Impact factor: 2.984

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.