Literature DB >> 26542421

The influence of number of line pairs in digital intra-oral radiography on the detection accuracy of horizontal root fractures.

Yuri Nejaim1, Amanda Farias Gomes1, Emmanuel João Nogueira Leal da Silva2, Francisco Carlos Groppo3, Francisco Haiter Neto1.   

Abstract

AIM: Line pairs are the unit for measurement of resolution and are related to the spatial quality of the system. Thus, the objective of this study was to evaluate the influence of number of line pairs in digital intra-oral radiography on the detection accuracy of horizontal root fractures.
MATERIALS AND METHODS: Sixty-four extracted single-root human teeth were used. Thirty-two had horizontal root fractures created and were mounted in dry human mandibles. The teeth were radiographed with two digital receptors: the Digora Optime (14.3 lp mm-1) and the Digora Toto (26.3 lp mm-1). Images were viewed under standardized conditions by 3 calibrated examiners using the respective dedicated software (Digora for Windows 2.6(®) and Scanora(®) ). Digora Toto(®) images were also evaluated through the Digora for Windows 2.6(®) software. The results were statistically analyzed based on the area under the ROC curve for each examiner.
RESULTS: Pairing Digora Toto(®) with Scanora(®) allowed for greater accuracy in horizontal root fractures diagnosis, while images acquired with that same system seem to lose accuracy when visualized with Digora for Windows 2.6(®) . Pairing Digora Optime(®) with Digora for Windows 2.6(®) resulted in the lowest accuracy for horizontal root fractures diagnosis.
CONCLUSIONS: The higher number of line pairs and the consequent higher image resolution provided by the Digora Toto(®) system and its dedicated software seem to enhance the accuracy of horizontal root fractures diagnostic imaging.
© 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Diagnostic Imaging; Digital radiography; Radiology; Tooth Fractures

Mesh:

Year:  2015        PMID: 26542421     DOI: 10.1111/edt.12243

Source DB:  PubMed          Journal:  Dent Traumatol        ISSN: 1600-4469            Impact factor:   3.333


  5 in total

1.  Influence of the incorporation of a lead foil to intraoral digital receptors on the image quality and root fracture diagnosis.

Authors:  Amanda Farias Gomes; Yuri Nejaim; Rocharles Cavalcante Fontenele; Francisco Haiter-Neto; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2019-05-08       Impact factor: 2.419

2.  Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates.

Authors:  Amir Eskandarloo; Arman Yousefi; Setareh Soheili; Karim Ghazikhanloo; Payam Amini; Haniyeh Mohammadpoor
Journal:  Open Dent J       Date:  2017-12-29

3.  Numerical Evaluation of Image Contrast for Thicker and Thinner Objects among Current Intraoral Digital Imaging Systems.

Authors:  Oyunbat Dashpuntsag; Midori Yoshida; Ryosuke Kasai; Naoki Maeda; Hidehiko Hosoki; Eiichi Honda
Journal:  Biomed Res Int       Date:  2017-04-09       Impact factor: 3.411

4.  Digital file format does not influence the radiographic diagnosis of vertical root fracture.

Authors:  Murilo Miranda-Viana; Rocharles Cavalcante Fontenele; Amanda Farias Gomes; Fernanda Nogueira-Reis; Yuri Nejaim; Matheus L Oliveira; Deborah Queiroz Freitas
Journal:  Oral Radiol       Date:  2021-10-09       Impact factor: 1.882

5.  Evaluation of the combined assessment of two digital enhancement filters in periapical radiographs obtained with different projection angles in the detection of simulated dental root fractures.

Authors:  Victor Aquino Wanderley; Matheus L Oliveira; Ana Lidia Pinheiro Silva; Guilherme Monteiro Tosoni
Journal:  Oral Radiol       Date:  2021-06-30       Impact factor: 1.852

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.