Literature DB >> 26528498

Enhancing proficiency in performing endoscopic submucosal dissection (ESD) by using a prototype robotic endoscope.

Philip WaiYan Chiu1, Soo Jay Phee2, Pradeep Bhandari3, Kazuki Sumiyama4, Tomohiko Ohya4, Jennie Wong5, Carmen Cy Poon1, Hisao Tajiri4, Kiyokazu Nakajima6, Khek Yu Ho7.   

Abstract

BACKGROUND AND STUDY AIMS: One of the challenges in performing endoscopic submucosal dissection (ESD) is the lack of counter traction during submucosal dissection. MASTER (Master and Slave Transluminal Endoscopic Robot) was designed to allow performance of complex endoluminal procedures using two arms with excellent control. This study aimed to compare the performance of ESD between endoscopists and novices using MASTER.
METHODS: This is a prospective study comparing the differences in performing ESD using MASTER in an ex vivo porcine stomach model among individuals with or without experience in surgery and endoscopy. Multiple standardized lesions of 20 mm(2) were pre-marked on an ex vivo porcine stomach. Each participant received basic training in controlling MASTER before the ESD procedure. The operative time and size of specimen obtained by each participant were noted.
RESULTS: Nine individuals (three ESD expert endoscopists, three ESD non-expert endoscopists, and three non-clinician novices) participated in the experiment. All participants completed the ESD procedure for en bloc resection of standardized lesions using EndoMASTER without perforation. The mean times (mean ± SD) taken by ESD expert endoscopists, ESD non-expert endoscopists, and novices to complete Robotic ESD were 122 ± 58 s, 203 ± 150 s, and 561 ± 496 s, respectively. There was no statistically significant difference in the mean operative time to complete the ESD between the three groups (P = 0.242). When the performance of the six endoscopists was compared to that of the three novices, the endoscopists took an average of 162 ± 111 s to complete the ESD, while the non-clinicians required an average of 561 ± 496 s (P = 0.085).
CONCLUSIONS: There was a trend to shorter operative time when comparing endoscopists to non-endoscopists in performing ESD using MASTER. The use of MASTER enabled the novice without endoscopy experience to complete the ESD procedure.

Entities:  

Year:  2015        PMID: 26528498      PMCID: PMC4612240          DOI: 10.1055/s-0034-1393178

Source DB:  PubMed          Journal:  Endosc Int Open        ISSN: 2196-9736


Introduction

Gastrointestinal cancers remain the most common and important cancer worldwide 1. Early diagnosis of gastrointestinal cancers will lead to improvement in clinical outcomes and survival. For early gastrointestinal cancers with minimal risk of lymph node metastasis, endoscopic resection is the current standard of treatment 2. Endoscopic resection with the technique of endoscopic submucosal dissection (ESD) achieved a high rate of en bloc resection. Retrospective cohort studies showed that ESD reduced the rate of local recurrence when compared to endoscopic mucosal resection (EMR) 3 4. Despite the advantages in oncological clearance, ESD is technically challenging. A study on the learning curve for ESD showed that the en bloc resection rate increased from 45 % to 85 % after the first 40 cases, while the perforation rate decreased after the initial 20 cases 5. We conducted a study of the preclinical training for experienced endoscopists to perform ESD in a porcine model 6. Despite their vast experience in esophagogastroduodenoscopy (EGD), colonoscopy, and endoscopic retrograde cholangiopancreatoscopy (ERCP), 62 % of the participants achieved a perforation upon first performance of ESD. The development of Master and Slave Transluminal Endoscopic Robot (MASTER) aimed to improve the performance of complex endoluminal procedures by mounting two robotic arms onto an ordinary double channel endoscope 7. A multicenter prospective cohort study had confirmed the feasibility and safety in performing ESD using MASTER to treat early gastric cancer in five patients 8. The current study aimed to investigate the enhancement of proficiency in performing ESD using MASTER through a comparison of ESD experts, ESD non-experts, and novices in an ex vivo porcine stomach model.

Method

This is a prospective preclinical study investigating the effects of use of a prototype robotic endoscope on the proficiency of performing ESD in an ex vivo porcine stomach model. Three groups of participants were invited to perform ESD using the Master and Slave Transluminal Endoscopic Robot (MASTER). The first group consisted of ESD expert endoscopists who had performed more than 100 cases of ESD. The second group consisted of ESD non-expert endoscopists with vast experience in performing esophagogastroduodenoscopy (EGD), colonoscopy as well as endoscopic retrograde cholangiopancreatoscopy (ERCP). They either had experience with less than 10 cases of ESD or had never performed the procedure. The third group consisted of novices who had never performed any endoscopic procedure. They were engineers involved in material design not related to endoscopy. All of the procedures were performed using the MASTER endoscopic robot which was held by a single endoscopist (KYH) experienced in handling the MASTER robot (Fig. 1). In order to standardize the size of the lesion for the trial, we created a standard 20 mm circular cardboard disc which was then used to create standard 20 mm circular lesions with diathermy markings (ERBE 300 D, ERBE, Germany) in an ex vivo porcine stomach. After submucosal injection of normal saline mixed with indigo carmine, a circumferential mucosal incision was made using an IT2 knife (Olympus Co Ltd, Japan) (Fig. 1). The study started after completion of the circumferential mucosal incision. All participants completed the ESD procedure using the MASTER robot (Fig. 2). The steps for performance of ESD were standardized as: 1. Grasping of the mucosa using the right arm of the MASTER; 2. Elevation of the mucosa after grasping to expose the submucosal plane; 3. Submucosal dissection using the left arm with the diathermy hook; and 4. Repeating the procedure until complete dissection of the gastric lesion had been achieved.
Fig. 1

 Setting for conduction of the preclinical ex vivo porcine stomach ESD using the MASTER robotic endoscope. a Setting for the ex vivo model and the MASTER. b Standardized gastric lesions for performing ESD using the robotic endoscopic platform.

Fig. 2 a

External view demonstrating submucosal dissection using the MASTER robotic endoscope. b Endoscopic view showing lifting of mucosa and submucosal dissection using the MASTER robotic endoscope.

Setting for conduction of the preclinical ex vivo porcine stomach ESD using the MASTER robotic endoscope. a Setting for the ex vivo model and the MASTER. b Standardized gastric lesions for performing ESD using the robotic endoscopic platform. External view demonstrating submucosal dissection using the MASTER robotic endoscope. b Endoscopic view showing lifting of mucosa and submucosal dissection using the MASTER robotic endoscope. Each of the participants performed three ESD procedures, and all procedures were video-recorded and timed. The outcomes included the time for first successful grasp of the mucosa, time to achieve adequate elevation and exposure of the submucosa, time for performance of submucosal dissection, and total time for the procedure. We recorded all perforations during the procedure. This study was approved by National University of Singapore Institutional Animal Care and Use Committee (IACUC protocol no: 024/12). All of the data were analyzed using SPSS version 11.0. The analysis of continuous data was performed using the Student's t test, while the categorical data were analyzed with the Chi-squared test. Intergroup comparison was conducted using one-way ANOVA. We defined statistically significant results as having a P value less than 0.05.

Results

A total of nine participants completed the ESD procedures for resection of the standardized 20 mm lesion using the MASTER endoscopic robot. Table 1 shows the baseline demographics for the different groups of participants. The ESD expert group consisted of one surgeon and two gastroenterologists. The ESD non-expert endoscopists group consisted of two surgeons and one gastroenterologist. The non-clinician novice group consisted of three engineers focusing on material design and development without experience in performing endoscopy. Table 1 illustrates that the endoscopists in the ESD expert group were more experienced and had performed many more endoscopic procedures than the ESD non-expert group of endoscopists.

Baseline demographics for the participants.

Participant groupsYears as specialist endoscopist (Gastroenterologist/Surgeon)No. of EGD performedNo. of colonoscopies performedNo. of ERCP performed
ESD expert endoscopists12.6710666.75000.0438.0
ESD non-expert endoscopists12.33 6766.72266.7333.3
Novices 0  0   0  0

EGD, esophagogastroduodenoscopy; ERCP, endoscopic retrograde cholangiopancreatoscopy.

ESD expert group consisted of one surgeon and two gastroenterologists; ESD non-expert group consisted of two surgeons and one gastroenterologist; Novice group consisted of engineers without experience in performing endoscopy.

EGD, esophagogastroduodenoscopy; ERCP, endoscopic retrograde cholangiopancreatoscopy. ESD expert group consisted of one surgeon and two gastroenterologists; ESD non-expert group consisted of two surgeons and one gastroenterologist; Novice group consisted of engineers without experience in performing endoscopy. All participants were able to complete the ESD procedures and there were no perforations during the procedure. When the operative times were compared between the three groups, there was no difference in the time for first grasping of mucosa, time to expose the submucosa, time for submucosal dissection, and total time for the procedure (Fig. 3). There was a trend towards longer operative time for the non-clinician novice to complete the submucosal dissection though the difference was not statistically significant. The average operative time for MASTER ESD was 121.7 ± 57.7 s for the ESD expert group, 202.7 ± 149.5 s for the ESD non-expert group, and 561.0 ± 495.6 s for the novice group (P = 0.242) (Fig. 4). When all the clinicians were grouped to compare with the non-clinicians, we found that there was a trend towards a longer total dissection time (P = 0.085; 95 %CI = – 70.8 to 868.5) and submucosal dissection time (P = 0.078; 95 %CI = – 48.5 to 705.8) for the non-clinician group as compared to clinician group, however these differences were not significant.
Fig. 3

 Comparison of the operative time (s) for MASTER ESD among ESD experts, non-experts, and novice study groups.

Fig. 4

 Comparison of the operative time (s) for MASTER ESD between endoscopist and non-endoscopist study groups.

Comparison of the operative time (s) for MASTER ESD among ESD experts, non-experts, and novice study groups. Comparison of the operative time (s) for MASTER ESD between endoscopist and non-endoscopist study groups.

Discussion

Gastrointestinal cancers are important causes of cancer worldwide 1. Colorectal, gastric, and esophageal cancers ranked the second, fourth, and fifth most common cancers in Asia 9. The majority of gastrointestinal cancers are diagnosed at late stage with grave prognosis despite major surgery and oncological therapies. On the other hand, early stage gastrointestinal cancers carry excellent prognosis with 5-year survival of over 85 % if treated appropriately 10. Intramucosal early gastrointestinal cancers can be treated by endoscopic resection with adequate oncological clearance due to minimal risk of lymph node metastasis 11. ESD has emerged as a safe and effective method of endoscopic resection with a high rate of en bloc resection. Recently, ESD is being increasingly practiced in countries outside Japan and Korea. A European series reported 82 cases of epithelial or submucosal lesions treated with ESD 12. The en bloc resection rate was 77.1 %, while the local recurrence was 0 % after R0 resection compared to 38.5 % after piecemeal resection. Although the procedural time per specimen size was significantly shorter in the second half of the study, the authors commented that ESD was difficult, time consuming, and required a prolonged learning curve. One of the reasons for the difficulties in ESD is the lack of appropriate endoscopic instruments and platform for performing the dissection. Unlike minimally invasive surgery where surgeons performed dissection using two instruments under the laparoscope in a triangulation manner, ESD is performed in a single handed manner with the instrument co-axially aligned with the endoscope. The advantages of the Da Vinci Robotic surgical system was clearly demonstrated in performing complex surgical tasks within a confined space during radical prostatectomy 13. The development of the MASTER aimed to improved surgical dissection within the gastrointestinal lumen through a flexible endoscopic platform mounted with two robotic arms 7 14. The current study employed the first generation of MASTER robotic endoscope which has two robotic arms, one with a dissection hook and the other with a forceps attached to an ordinary dual channel endoscope. Our results demonstrate that the techniques and outcomes of ESD can be standardized using the MASTER. Standardization of ESD technique using devices such as the MASTER raises hope for a large number of endoscopists worldwide to practice ESD, who may find the procedure to be technically challenging, requiring prolonged procedural times, and associated with a high complication rate. The other challenge facing the widespread applicability of ESD is the learning curve. It is well known that this can be very long especially in centers with a small case load and few experts. In our study, the non-clinician group with no experience in endoscopy managed to grasp the concept of ESD and complete the procedure within 20 min. This may suggest that devices such as the MASTER can significantly shorten the learning curve for ESD. The procedure for ESD was greatly enhanced by using the two end effectors for dissection, one of the aims being to attain adequate exposure of the submucosal plane with the other aim being safe dissection. As participants in the novice group were engineers with no previous experience in performing endoscopy or ESD, robotic technology is one of the methods used to overcome inadequate experience and learning curve. This is important evidence to demonstrate that flexible robotic technologies will enhance the performance of complex dissection within the gastrointestinal lumen. This study was limited by several factors. The model employed was an ex vivo porcine stomach, hence bleeding during ESD could not be simulated. Moreover, the size of the lesion was small, which might not be representative of a true gastric ESD, especially from the viewpoint of risk of perforation. The number of participants and the number of MASTER ESD procedures performed were limited. As it was an ex vivo model study, the results may not be directly applicable to human patients. The prototype MASTER robotic system also had limitations. In the clinical setting, one of the major limitations was the inability to interchange the two robotic arms. This led to the need for twisting and torque of the endoscope to facilitate dissection. We can expect future refinement of the MASTER robot before clinical application. In summary, we have demonstrated that the procedure for ESD and its outcomes can be standardized and enhanced using the MASTER robot, and produced comparable results between ESD experts and non-experts. We also demonstrated that MASTER enabled novices to learn and perform simple ESD procedures to acceptable standards after a short training period. Using the prototype MASTER endoscopic robotic platform. Comparison between expert and novice endoscopists. Video 1
  13 in total

1.  Endoscopic submucosal dissection of gastric lesions by using a Master and Slave Transluminal Endoscopic Robot (MASTER).

Authors:  Khek-Yu Ho; Soo Jay Phee; Asim Shabbir; Soon Chiang Low; Van An Huynh; Andy Prima Kencana; Kai Yang; Davide Lomanto; Bok Yan Jimmy So; Y Y Jennie Wong; S C Sydney Chung
Journal:  Gastrointest Endosc       Date:  2010-06-19       Impact factor: 9.427

2.  Endoscopic submucosal dissection of gastric lesions by using a master and slave transluminal endoscopic robot: an animal survival study.

Authors:  Z Wang; S J Phee; D Lomanto; R Goel; P Rebala; Z L Sun; S Trasti; N Reddy; J Y Y Wong; K Y Ho
Journal:  Endoscopy       Date:  2012-06-21       Impact factor: 10.093

3.  Endoscopic submucosal dissection of early cancers, flat adenomas, and submucosal tumors in the gastrointestinal tract.

Authors:  Andreas Probst; Daniela Golger; Hans Arnholdt; Helmut Messmann
Journal:  Clin Gastroenterol Hepatol       Date:  2008-09-20       Impact factor: 11.382

Review 4.  Early gastric cancer in Europe.

Authors:  S M Everett; A T Axon
Journal:  Gut       Date:  1997-08       Impact factor: 23.059

5.  Advantage of endoscopic submucosal dissection compared with EMR for early gastric cancer.

Authors:  Shiro Oka; Shinji Tanaka; Iwao Kaneko; Ritsuo Mouri; Mayuko Hirata; Toru Kawamura; Masaharu Yoshihara; Kazuaki Chayama
Journal:  Gastrointest Endosc       Date:  2006-09-20       Impact factor: 9.427

6.  Incidence of lymph node metastasis from early gastric cancer: estimation with a large number of cases at two large centers.

Authors:  Takuji Gotoda; Akio Yanagisawa; Mitsuru Sasako; Hiroyuki Ono; Yukihiro Nakanishi; Tadakazu Shimoda; Yo Kato
Journal:  Gastric Cancer       Date:  2000-12       Impact factor: 7.370

Review 7.  Novel endoscopic therapeutics for early gastric cancer.

Authors:  Philip Wai Yan Chiu
Journal:  Clin Gastroenterol Hepatol       Date:  2013-08-15       Impact factor: 11.382

8.  Digestive cancer management in Asia: position statements: a report on GI Oncology Summit in 2011.

Authors:  Joseph J Y Sung; Enders K W Ng; Jaw-Town Lin; K Y Ho; Jia-Fu Ji; Kentaro Sugano; Ronnie T P Poon; Anthony T C Chan; Khean-Lee Goh; Kwang-Hyub Han; Leo L T Chen; Kai-Chun Wu; Simon S M Ng; Robert S Bresalier; Francis K L Chan
Journal:  J Gastroenterol Hepatol       Date:  2012-09       Impact factor: 4.029

9.  Clinical outcomes of EMR for gastric tumors: historical pilot evaluation between endoscopic submucosal dissection and conventional mucosal resection.

Authors:  Kenichiro Watanabe; Shinichi Ogata; Seiji Kawazoe; Kazuyo Watanabe; Takanori Koyama; Tetsuro Kajiwara; Yuichiro Shimoda; Yukari Takase; Kouji Irie; Masanobu Mizuguchi; Seiji Tsunada; Ryuichi Iwakiri; Kazuma Fujimoto
Journal:  Gastrointest Endosc       Date:  2006-05       Impact factor: 9.427

10.  Difficulties and outcomes in starting endoscopic submucosal dissection.

Authors:  Anthony Yuen Bun Teoh; Philip Wai Yan Chiu; Simon Kin Hung Wong; Joseph Jao Yiu Sung; James Yun Wong Lau; Enders Kwok Wai Ng
Journal:  Surg Endosc       Date:  2009-11-13       Impact factor: 4.584

View more
  6 in total

Review 1.  Recent traction methods for endoscopic submucosal dissection.

Authors:  Kunihiro Tsuji; Naohiro Yoshida; Hiroyoshi Nakanishi; Kenichi Takemura; Shinya Yamada; Hisashi Doyama
Journal:  World J Gastroenterol       Date:  2016-07-14       Impact factor: 5.742

Review 2.  Polypectomy and advanced endoscopic resection.

Authors:  Kesavan Kandiah; Sharmila Subramaniam; Pradeep Bhandari
Journal:  Frontline Gastroenterol       Date:  2017-02-10

Review 3.  Current Endoscopic Resection Techniques for Gastrointestinal Lesions: Endoscopic Mucosal Resection, Submucosal Dissection, and Full-Thickness Resection.

Authors:  Arthur Hoffman; Raja Atreya; Timo Rath; Markus Ferdinand Neurath
Journal:  Visc Med       Date:  2021-03-31

Review 4.  Flexible Gastro-intestinal Endoscopy - Clinical Challenges and Technical Achievements.

Authors:  Niehls Kurniawan; Martin Keuchel
Journal:  Comput Struct Biotechnol J       Date:  2017-01-18       Impact factor: 7.271

5.  Global Evaluative Assessment of Robotic Skills in Endoscopy (GEARS-E): objective assessment tool for master and slave transluminal endoscopic robot.

Authors:  Nobuyoshi Takeshita; Soo Jay Phee; Philip WaiYan Chiu; Khek Yu Ho
Journal:  Endosc Int Open       Date:  2018-08-10

6.  A Pilot Study of Endoscopic Submucosal Dissection Using an Endoscopic Assistive Robot in a Porcine Stomach Model.

Authors:  Byung Gon Kim; Hyuk Soon Choi; Sei Hoon Park; Jun Ho Hong; Jung Min Lee; Seung Han Kim; Hoon Jai Chun; Daehie Hong; Bora Keum
Journal:  Gut Liver       Date:  2019-07-15       Impact factor: 4.519

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.