Literature DB >> 26527594

Incidence of Hardware Removal Following Volar Plate Fixation of Distal Radius Fracture.

Kevin F Lutsky, Pedro K Beredjiklian, Stephen Hioe, Justin Bilello, Nayoung Kim, Jonas L Matzon.   

Abstract

PURPOSE: To assess the risk of tendon rupture or plate removal after volar plate fixation of distal radius fractures and to determine the incidence of hardware removal.
METHODS: We searched the surgical database of 5 attending hand surgeons at a single institution from 2009 to 2014. All patients who had undergone volar plate fixation were included. Patients were excluded if they underwent an alternate form of fixation, had less than 1 year of follow-up, or could not be reached for follow-up. Postoperative radiographs were examined for Soong grade, plate distance to the critical line, and plate distance to the volar rim. If patients had hardware removed, the reason for plate removal was identified. For all patients who did not have documented hardware removal at our institution, we placed a follow-up call to determine whether they had hardware removed elsewhere.
RESULTS: A total of 517 patients underwent volar plate fixation, 143 of whom did not have their hardware removed at our institution but could not be reached for follow-up. Of the remaining 374 patients, 37 (10%) had hardware removed. For group 1 (hardware retained), Soong grades were 13% grade 0, 85% grade 1, and 2% grade 2. For group 2 (hardware removed) the proportions were 11%, 76%, and 5%, respectively, and 8% undetermined. Mean plate distance to the critical line was significantly greater for group 2 (1.9 mm) compared with group 1 (1.2 mm). Mean plate distance to the volar rim did not differ (5.1 mm vs 5.3 mm).
CONCLUSIONS: The incidence of hardware removal in our series was 10%. The vast majority of patients had Soong grade 1 prominence. Patients who had hardware removed had a greater plate prominence volar to the critical line. Plate distance to the volar rim was not associated with removal. TYPE OF STUDY/LEVEL OF EVIDENCE: Prognostic II.
Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Critical line; distal radius fracture; hardware removal; prominence; volar line

Mesh:

Year:  2015        PMID: 26527594     DOI: 10.1016/j.jhsa.2015.09.017

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  16 in total

1.  Older Patient Preferences for Internal Fixation after a Distal Radius Fracture: A Qualitative Study from the Wrist and Radius Injury Surgical Trial.

Authors:  Jacob S Nasser; Helen E Huetteman; Melissa J Shauver; Kevin C Chung
Journal:  Plast Reconstr Surg       Date:  2018-07       Impact factor: 4.730

2.  Incidence of tendon rupture following volar plate fixation of distal radius fractures: A survey of 2787 cases.

Authors:  Kotaro Sato; Kenya Murakami; Yoshikuni Mimata; Minoru Doita
Journal:  J Orthop       Date:  2018-02-03

3.  Impact of Design on Force between Flexor Tendons and Distal Radius Volar Plates.

Authors:  Katharine M Hinchcliff; Ido Volk; Xenia Ivanova; Sandra Taylor; Robert M Szabo
Journal:  J Wrist Surg       Date:  2019-03-25

4.  Clinical and ultrasonographical follow-up after standard removal of distal radius volar plates positioned distal to the watershed line.

Authors:  Chul Ki Goorens; Pieter-Bastiaan De Keyzer; Jean François Goubau
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-05-04

5.  Implant Removal Matrix for the upper Extremity Orthopedic Surgeon.

Authors:  Patrick K Cronin; Ian T Watkins; Matthew Riedel; Philip B Kaiser; John Y Kwon
Journal:  Arch Bone Jt Surg       Date:  2020-01

6.  Smoking Increases Postoperative Complications After Distal Radius Fracture Fixation: A Review of 417 Patients From a Level 1 Trauma Center.

Authors:  Daniel E Hess; S Evan Carstensen; Spencer Moore; A Rashard Dacus
Journal:  Hand (N Y)       Date:  2018-11-22

7.  Outcomes of Open Reduction and Internal Fixation of Bilateral Fractures of the Distal Radius.

Authors:  Jack G Graham; Sreeram Penna; Daniel Fletcher; Moody Kwok; Daren J Aita; T Robert Takei; Pedro K Beredjiklian
Journal:  J Hand Microsurg       Date:  2019-05-26

8.  Incidence of Flexor Pollicis Longus Complications Following Volar Locking Plate Fixation of Distal Radius Fractures.

Authors:  Alyssa Cook; Paul Baldwin; John R Fowler
Journal:  Hand (N Y)       Date:  2019-01-08

9.  Correlation of Flexor Pollicis Longus Tendon Status by Ultrasonography with Plate Position on Radiographs Following Volar Plate Fixation of Distal Radius Fractures with Pronator Quadratus Repair.

Authors:  Anil K Bhat; Ashwath M Acharya; Prajwal P Mane; Lakshmikanth H Karegowda
Journal:  Indian J Orthop       Date:  2021-02-19       Impact factor: 1.251

10.  Incidence for volar locking plate removal following distal radius fracture surgery.

Authors:  Vili Palola; Ville Ponkilainen; Tuomas Huttunen; Antti Launonen; Ville M Mattila
Journal:  Arch Orthop Trauma Surg       Date:  2020-08-30       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.