Literature DB >> 26527374

Balloon-expandable transcatheter aortic valve replacement in patients with extreme aortic valve calcification.

Yigal Abramowitz1, Hasan Jilaihawi1, Tarun Chakravarty1, Mohammad Kashif1, George Matar1, Babak Hariri1, Jigar Patel1, Mamoo Nakamura1, Wen Cheng1, Raj R Makkar1.   

Abstract

OBJECTIVES: To assess the procedural and short-term clinical outcome of performing balloon-expandable TAVR in patients with extremely calcified aortic valves.
BACKGROUND: Quantity of aortic valve calcification predicts rates of paravalvular regurgitation (PVR) post transcatheter aortic valve replacement (TAVR). Nonetheless, short-term outcomes of balloon-expandable TAVR in patients with extremely high calcified aortic valves have not been previously described.
METHODS: We studied patients with severe aortic stenosis that underwent balloon-expandable TAVR and had a pre-procedural non-contrast CT. Twenty patients that had aortic valve calcification score (AVCS) of more than 8,000 Agatston Units were compared to 279 patients with lower calcification scores. TAVR endpoints, device success and adverse events were considered according to the Valve Academic Research Consortium-2 definitions.
RESULTS: Device success was 80% in the extremely high calcification group compared to 95.3% in patients with less calcified aortic valves (P = 0.004). There was significantly more postprocedural PVR in the extreme calcification group: 50%, 35%, 10%, 5% vs. 72.4%, 25.8%, 1.8%, 0% for no/trace, mild, moderate and severe PVR, respectively (P < 0.001). There was one case of ascending aortic perforation resulting in intramural hematoma that resolved with no treatment. In-hospital mortality, new pacemaker implantation and major complications were similar between groups.
CONCLUSIONS: Balloon-expandable TAVR in patients with extremely calcified aortic valve is associated with lower device success and greater risk of PVR.
© 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  aortic valve disease; electron beam CT/multidetector CT; imaging; percutaneous intervention

Mesh:

Year:  2015        PMID: 26527374     DOI: 10.1002/ccd.26311

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  Predilatation Prior to Transcatheter Aortic Valve Implantation: Is it Still a Prerequisite?

Authors:  Matteo Pagnesi; Luca Baldetti; Paolo Del Sole; Antonio Mangieri; Marco B Ancona; Damiano Regazzoli; Nicola Buzzatti; Francesco Giannini; Antonio Colombo; Azeem Latib
Journal:  Interv Cardiol       Date:  2017-09

2.  Preoperative evaluation of transcatheter aortic valve replacement with assistance of 3D printing technique: Reanalysis of 4 death cases.

Authors:  Hao Zhang; Yu Shen; Lei Zhang; Chao Song; Zaiping Jing; Qingsheng Lu
Journal:  J Interv Med       Date:  2019-10-23
  2 in total