Hemodynamic Effects of Ventricular Assist Device Implantation on Norwood, Glenn, and Fontan Circulation: A Simulation Study.

Arianna Di Molfetta1, Antonio Amodeo1, Maria G Gagliardi1, Maria G Trivella2, Libera Fresiello3, Sergio Filippelli1, Alessandra Toscano1, Gianfranco Ferrari2.   

Abstract

The growing population of failing single-ventricle (SV) patients might benefit from ventricular assist device (VAD) support as a bridge to heart transplantation. However, the documented experience is limited to isolated case reports. Considering the complex and different physiopathology of Norwood, Glenn, and Fontan patients and the lack of established experience, the aim of this work is to realize and test a lumped parameter model of the cardiovascular system able to simulate SV hemodynamics and VAD implantation effects to support clinical decision. Hemodynamic and echocardiographic data of 30 SV patients (10 Norwood, 10 Glenn, and 10 Fontan) were retrospectively collected and used to simulate patients' baseline. Then, the effects of VAD implantation were simulated. Simulation results suggest that the implantation of VAD: (i) increases the cardiac output and the mean arterial systemic pressure in all the three palliation conditions (Norwood 77.2 and 19.7%, Glenn 38.6 and 32.2%, and Fontan 17.2 and 14.2%); (ii) decreases the SV external work (Norwood 55%, Glenn 35.6%, and Fontan 41%); (iii) decreases the pressure pulsatility index (Norwood 65.2%, Glenn 81.3%, and Fontan 64.8%); (iv) increases the pulmonary arterial pressure in particular in the Norwood circulation (Norwood 39.7%, Glenn 12.1% and Fontan 3%); and (v) decreases the atrial pressure (Norwood 2%, Glenn 10.6%, and Fontan 8.6%). Finally, the VAD work is lower in the Norwood circulation (30.4 mL·mm Hg) in comparison with Fontan (40.3 mL·mm Hg) and to Glenn (64.5 mL·mm Hg) circulations. The use of VAD in SV physiology could be helpful to bridge patients to heart transplantations by increasing the CO and unloading the SV with a decrement of the atrial pressure and the SV external work. The regulation of the pulmonary flow is challenging because the Pap is increased by the presence of VAD. The hemodynamic changes are different in the different SV palliation step. The use of numerical models could be helpful to support patient and VAD selection to optimize the clinical outcome.
Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  Lumped parameter model; Single-ventricle physiology; Ventricular assist devices

Mesh:

Year:  2015        PMID: 26526959     DOI: 10.1111/aor.12591

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  6 in total

Review 1.  Improving medical care and prevention in adults with congenital heart disease-reflections on a global problem-part I: development of congenital cardiology, epidemiology, clinical aspects, heart failure, cardiac arrhythmia.

Authors:  Rhoia Neidenbach; Koichiro Niwa; Oeztekin Oto; Erwin Oechslin; Jamil Aboulhosn; David Celermajer; Joerg Schelling; Lars Pieper; Linda Sanftenberg; Renate Oberhoffer; Fokko de Haan; Michael Weyand; Stephan Achenbach; Christian Schlensak; Dirk Lossnitzer; Nicole Nagdyman; Yskert von Kodolitsch; Hans-Carlo Kallfelz; David Pittrow; Ulrike M M Bauer; Peter Ewert; Thomas Meinertz; Harald Kaemmerer
Journal:  Cardiovasc Diagn Ther       Date:  2018-12

Review 2.  An overview of mechanical circulatory support in single-ventricle patients.

Authors:  Jacob R Miller; Timothy S Lancaster; Connor Callahan; Aaron M Abarbanell; Pirooz Eghtesady
Journal:  Transl Pediatr       Date:  2018-04

3.  A computational study of the Fontan circulation with fenestration or hepatic vein exclusion.

Authors:  Charles Puelz; Sebastián Acosta; Béatrice Rivière; Daniel J Penny; Ken M Brady; Craig G Rusin
Journal:  Comput Biol Med       Date:  2017-08-25       Impact factor: 4.589

4.  The Hemodynamics of Patent Ductus Arteriosus in Patients after Central Shunt Operation.

Authors:  Pan Xu; Haiyun Yuan; Jian Zhuang; Neichuan Zhang; Qianjun Jia; Yuhao Dong; Qifei Jian; Meiping Huang
Journal:  Comput Math Methods Med       Date:  2021-04-24       Impact factor: 2.238

5.  3D Simulation Analysis of Central Shunt in Patient-Specific Hemodynamics: Effects of Varying Degree of Pulmonary Artery Stenosis and Shunt Diameters.

Authors:  Jiawei Liu; Haiyun Yuan; Neichuan Zhang; Xiangyu Chen; Chengbin Zhou; Meiping Huang; Qifei Jian; Jian Zhuang
Journal:  Comput Math Methods Med       Date:  2020-02-14       Impact factor: 2.238

6.  In-vitro performance of a single-chambered total artificial heart in a Fontan circulation.

Authors:  Stephan Hildebrand; Sascha Groß-Hardt; Thomas Schmitz-Rode; Ulrich Steinseifer; Sebastian Victor Jansen
Journal:  J Artif Organs       Date:  2021-05-06       Impact factor: 1.731

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.