Literature DB >> 26521066

The feasibility of sub-millisievert coronary CT angiography with low tube voltage, prospective ECG gating, and a knowledge-based iterative model reconstruction algorithm.

Chul Hwan Park1, Joohee Lee1, Chisuk Oh1, Kyung Hwa Han2, Tae Hoon Kim3.   

Abstract

We evaluated the feasibility of sub-millisievert (mSv) coronary CT angiography (CCTA) using low tube voltage, prospective ECG gating, and a knowledge-based iterative model reconstruction algorithm. Twenty-four non-obese healthy subjects (M:F 13:11; mean age 50.2 ± 7.8 years) were enrolled. Three sets of CT images were reconstructed using three different reconstruction methods: filtered back projection (FBP), iterative reconstruction (IR), and knowledge-based iterative model reconstruction (IMR). The scanning parameters were as follows: step-and-shoot axial scanning, 80 kVp, and 200 mAs. On the three sets of CT images, the attenuation and image noise values were measured at the aortic root. The signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) were calculated at the proximal right coronary artery and the left main coronary artery. The qualitative image quality of the CCTA with IMR was assessed using a 4-point grading scale (grade 1, poor; grade 4, excellent). The mean radiation dose of the CCTA was 0.89 ± 0.09 mSv. The attenuation values with IMR were not different from those of other reconstruction methods. The image noise with IMR was significantly lower than with IR and FBP. Compared to FBP, the noise reduction rate of IMR was 69 %. The SNR and CNR of CCTA with IMR were significantly higher than with FBP or IR. On the qualitative analysis with IMR, all included segments were diagnostic (grades 2, 3, and 4), and the mean image quality score was 3.6 ± 0.6. In conclusion, CCTA with low tube voltage, prospective ECG gating, and an IMR algorithm might be a feasible method that allows for sub-millisievert radiation doses and good image quality when used with non-obese subjects.

Entities:  

Keywords:  Coronary artery disease; Iterative model reconstruction; Low tube voltage; Multidetector computed tomography; Prospective ECG gating

Mesh:

Year:  2015        PMID: 26521066     DOI: 10.1007/s10554-015-0795-7

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  22 in total

Review 1.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

Review 2.  Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology.

Authors:  Stephen Schroeder; Stephan Achenbach; Frank Bengel; Christof Burgstahler; Filippo Cademartiri; Pim de Feyter; Richard George; Philipp Kaufmann; Andreas F Kopp; Juhani Knuuti; Dieter Ropers; Joanne Schuijf; Laurens F Tops; Jeroen J Bax
Journal:  Eur Heart J       Date:  2007-12-15       Impact factor: 29.983

3.  Low-dose computed tomography coronary angiography with prospective triggering: a promise for the future.

Authors:  Philipp A Kaufmann
Journal:  J Am Coll Cardiol       Date:  2008-10-28       Impact factor: 24.094

4.  Image quality and radiation exposure with prospectively ECG-triggered axial scanning for coronary CT angiography: the multicenter, multivendor, randomized PROTECTION-III study.

Authors:  Jörg Hausleiter; Tanja S Meyer; Eugenio Martuscelli; Pietro Spagnolo; Hiroaki Yamamoto; Patricia Carrascosa; Thomas Anger; Lukas Lehmkuhl; Hatem Alkadhi; Stefan Martinoff; Martin Hadamitzky; Franziska Hein; Bernhard Bischoff; Miriam Kuse; Albert Schömig; Stephan Achenbach
Journal:  JACC Cardiovasc Imaging       Date:  2012-05

5.  Value of knowledge-based iterative model reconstruction in low-kV 256-slice coronary CT angiography.

Authors:  Hideaki Yuki; Daisuke Utsunomiya; Yoshinori Funama; Shinichi Tokuyasu; Tomohiro Namimoto; Toshinori Hirai; Ryo Itatani; Kazuhiro Katahira; Shuichi Oshima; Yasuyuki Yamashita
Journal:  J Cardiovasc Comput Tomogr       Date:  2014-01-12

6.  A knowledge-based iterative model reconstruction algorithm: can super-low-dose cardiac CT be applicable in clinical settings?

Authors:  Seitaro Oda; Daisuke Utsunomiya; Yoshinori Funama; Kazuhiro Katahira; Keiichi Honda; Shinichi Tokuyasu; Mani Vembar; Hideaki Yuki; Katsuo Noda; Shuichi Oshima; Yasuyuki Yamashita
Journal:  Acad Radiol       Date:  2014-01       Impact factor: 3.173

Review 7.  Optimization of radiation dose reduction in cardiac computed tomographic angiography.

Authors:  Daniel W Entrikin; Jonathon A Leipsic; J Jeffrey Carr
Journal:  Cardiol Rev       Date:  2011 Jul-Aug       Impact factor: 2.644

8.  Iterative model reconstruction: improved image quality of low-tube-voltage prospective ECG-gated coronary CT angiography images at 256-slice CT.

Authors:  Seitaro Oda; Gaby Weissman; Mani Vembar; Wm Guy Weigold
Journal:  Eur J Radiol       Date:  2014-05-02       Impact factor: 3.528

9.  Assessment of a model-based, iterative reconstruction algorithm (MBIR) regarding image quality and dose reduction in liver computed tomography.

Authors:  Won Chang; Jeong Min Lee; Kyunghee Lee; Jeong Hee Yoon; Mi Hye Yu; Joon Koo Han; Byung Ihn Choi
Journal:  Invest Radiol       Date:  2013-08       Impact factor: 6.016

10.  Effect of low tube voltage on image quality, radiation dose, and low-contrast detectability at abdominal multidetector CT: phantom study.

Authors:  Kun Tang; Ling Wang; Rui Li; Jie Lin; Xiangwu Zheng; Guoquan Cao
Journal:  J Biomed Biotechnol       Date:  2012-04-23
View more
  8 in total

1.  Fusion of CT coronary angiography and whole-heart dynamic 3D cardiac MR perfusion: building a framework for comprehensive cardiac imaging.

Authors:  Jochen von Spiczak; Robert Manka; Alexander Gotschy; Sabrina Oebel; Sebastian Kozerke; Sandra Hamada; Hatem Alkadhi
Journal:  Int J Cardiovasc Imaging       Date:  2017-10-28       Impact factor: 2.357

2.  Advances in cardiac CT.

Authors:  Prabhakar Rajiah; Suhny Abbara
Journal:  Cardiovasc Diagn Ther       Date:  2017-10

3.  Influence of tube potential on quantitative coronary plaque analyses by low radiation dose computed tomography: a phantom study.

Authors:  Chunhong Wang; Yuliang Liao; Haibin Chen; Xin Zhen; Jianhong Li; Yikai Xu; Linghong Zhou
Journal:  Int J Cardiovasc Imaging       Date:  2018-03-26       Impact factor: 2.357

4.  Evaluation of the CT imaging findings in patients newly diagnosed with chronic thromboembolic pulmonary hypertension.

Authors:  Alexandra Grosse; Claudia Grosse; Irene Lang
Journal:  PLoS One       Date:  2018-07-30       Impact factor: 3.240

5.  Coronary CT Angiography with Knowledge-Based Iterative Model Reconstruction for Assessing Coronary Arteries and Non-Calcified Predominant Plaques.

Authors:  Tao Li; Tian Tang; Li Yang; Xinghua Zhang; Xueping Li; Chuncai Luo
Journal:  Korean J Radiol       Date:  2019-05       Impact factor: 3.500

6.  Non-inferior low-dose coronary computed tomography angiography image quality with knowledge-based iterative model reconstruction for overweight patients.

Authors:  In Kyung Park; Jeffrey Park; Tae Hoon Kim; Joohee Lee; Kyunghwa Han; Chisuk Oh; Chul Hwan Park
Journal:  PLoS One       Date:  2018-12-26       Impact factor: 3.240

7.  Coronary Computed Tomographic Angiography at 80 kVp and Knowledge-Based Iterative Model Reconstruction Is Non-Inferior to that at 100 kVp with Iterative Reconstruction.

Authors:  Joohee Lee; Chul Hwan Park; Chi Suk Oh; Kyunghwa Han; Tae Hoon Kim
Journal:  PLoS One       Date:  2016-09-22       Impact factor: 3.240

8.  Increasing iterative reconstruction strength at low tube voltage in coronary CT angiography protocols using 3D-printed and Catphan® 500 phantoms.

Authors:  Kamarul A Abdullah; Mark F McEntee; Warren M Reed; Peter L Kench
Journal:  J Appl Clin Med Phys       Date:  2020-07-13       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.