BACKGROUND: About 30% of patients do not have an effective cardiac resynchronization therapy (CRT). Routine assessment of CRT by devices interrogation (DI) is not entirely reliable. Additional information provide detailed QRS analysis in 24-hour ECG, however it is time-consuming. The aim of the study was the assessment of R/S ratio variability in lead V1 between selected fragments of 24-hour ECG as a predictor of incomplete biventricular pacing (BIVP) during full 24-hour ECG. METHODS: The 12-lead 24-hour ECGs of 43 patients with sinus rhythm were studied. During 24-hour ECG the 6-minute walk test (6MWT) was performed. The CRT was assessed by analyzing DI and full 24-hour ECG and four 1-minute fragments of these ECG recordings: during the minimum and the maximum heart rate and at the 1st and last minute of 6MWT. RESULTS: During DI the effective (>95%) BIVP was present in 36 patients (83.7%). Analysis of full 24-hour ECG confirmed appropriate BIVP in 31 patients (72%) and suspected incomplete BIVP (≤95%) in 12 patients (28%). In 9/12 patients the R/S ratio variability in lead V1 was visible between selected ECG fragments of 24-hour ECG. These results were not associated with the results of DI but were significantly associated with full 24-hour analysis of QRS. CONCLUSIONS: R/S variability in lead V1 between selected fragments of 24-hour ECG can be considered a predictor of potentially incomplete BIVP confirmed by further complete 24-hour ECG analysis in patients with appropriate pacing reported during DI.
BACKGROUND: About 30% of patients do not have an effective cardiac resynchronization therapy (CRT). Routine assessment of CRT by devices interrogation (DI) is not entirely reliable. Additional information provide detailed QRS analysis in 24-hour ECG, however it is time-consuming. The aim of the study was the assessment of R/S ratio variability in lead V1 between selected fragments of 24-hour ECG as a predictor of incomplete biventricular pacing (BIVP) during full 24-hour ECG. METHODS: The 12-lead 24-hour ECGs of 43 patients with sinus rhythm were studied. During 24-hour ECG the 6-minute walk test (6MWT) was performed. The CRT was assessed by analyzing DI and full 24-hour ECG and four 1-minute fragments of these ECG recordings: during the minimum and the maximum heart rate and at the 1st and last minute of 6MWT. RESULTS: During DI the effective (>95%) BIVP was present in 36 patients (83.7%). Analysis of full 24-hour ECG confirmed appropriate BIVP in 31 patients (72%) and suspected incomplete BIVP (≤95%) in 12 patients (28%). In 9/12 patients the R/S ratio variability in lead V1 was visible between selected ECG fragments of 24-hour ECG. These results were not associated with the results of DI but were significantly associated with full 24-hour analysis of QRS. CONCLUSIONS: R/S variability in lead V1 between selected fragments of 24-hour ECG can be considered a predictor of potentially incomplete BIVP confirmed by further complete 24-hour ECG analysis in patients with appropriate pacing reported during DI.
Authors: Panos E Vardas; Angelo Auricchio; Jean-Jacques Blanc; Jean-Claude Daubert; Helmut Drexler; Hugo Ector; Maurizio Gasparini; Cecilia Linde; Francisco Bello Morgado; Ali Oto; Richard Sutton; Maria Trusz-Gluza Journal: Eur Heart J Date: 2007-08-28 Impact factor: 29.983
Authors: Ganesh S Kamath; Delia Cotiga; Jayanthi N Koneru; Aysha Arshad; Walter Pierce; Emad F Aziz; Anisha Mandava; Suneet Mittal; Jonathan S Steinberg Journal: J Am Coll Cardiol Date: 2009-03-24 Impact factor: 24.094
Authors: Jonathan S Steinberg; Niraj Varma; Iwona Cygankiewicz; Peter Aziz; Paweł Balsam; Adrian Baranchuk; Daniel J Cantillon; Polychronis Dilaveris; Sergio J Dubner; Nabil El-Sherif; Jaroslaw Krol; Malgorzata Kurpesa; Maria Teresa La Rovere; Suave S Lobodzinski; Emanuela T Locati; Suneet Mittal; Brian Olshansky; Ewa Piotrowicz; Leslie Saxon; Peter H Stone; Larisa Tereshchenko; Mintu P Turakhia; Gioia Turitto; Neil J Wimmer; Richard L Verrier; Wojciech Zareba; Ryszard Piotrowicz Journal: Ann Noninvasive Electrocardiol Date: 2017-05 Impact factor: 1.468