Analysis of the QRS morphology in lead V1 during 24-hour Holter electrocardiogram monitoring to evaluate function of a cardiac resynchronisation therapy device in patients with sinus rhythm: a pilot study.

Dominika Pyszno-Prokopowicz1, Magdalena Madej, Rafał Baranowski, Ryszard Piotrowicz.   

Abstract

BACKGROUND: Cardiac resynchronisation therapy (CRT) is an important advance in the treatment of chronic heart failure. The aim of CRT is biventricular capture in all beats. However, inadequate delivery of biventricular pacing is still seen in about 30% of patients with an implanted CRT device. Device interrogation is a routine approach to assess CRT delivery. However, some reports indicate that analysis of 24-h electrocardiogram (ECG) may provide additional and important information regarding CRT function. AIM: Assessment of the adequacy of CRT delivery based on device interrogation and analysis of QRS morphology during 24-h ECG recording in patients with preserved sinus rhythm (SR).
METHODS: We analysed 24-h Holter ECG recordings and data from device interrogation devices in 43 patients with preserved SR (age 56 ± 23 years, 9 women and 34 men). The obtained results were compared in an independent manner. Assessment of adequacy of CRT delivery by 24-h ECG was based on the occurrence of QRS variability, defined as a change in R wave amplitude in lead V1 by > 3 mm and/or change in QRS duration by > 40 ms and/or change in the R/S ratio. Adequate CRT delivery, i.e. complete resynchronisation, was defined as more than 95% of pacing without the defined QRS variability.
RESULTS: Both methods allowed independent assessment of CRT delivery (p < 0.05 by the Fisher's exact test). In multivariate analysis, factors that were independently associated with incomplete resynchronisation included ventricular arrhythmias (each 100 ventricular beats per day increased the risk of incomplete resynchronisation 1.14-fold; confidence interval [CI] 1.036-1.25, p = 0.007), maximum heart rate (HR) (each increase by 10 bpm increased the risk 3.3-fold; CI 1.36-7.9, p = 0.008), QRS duration at the minimum HR (each increase by 10 ms increased the risk 1.74-fold; CI 1.075-2.8, p = 0.024), and the programmed atrioventricular delay (each increase by 10 ms increased the risk 2.15-fold, CI 1.18-3.9, p = 0.013).
CONCLUSIONS: In patients with preserved SR, device interrogation and evaluation of 24-h ECG are complementary methods to evaluate adequate CRT delivery. Therefore, both methods should be taken into account when assessing CRT function.

Entities:  

Mesh:

Year:  2015        PMID: 25563470     DOI: 10.5603/KP.a2014.0246

Source DB:  PubMed          Journal:  Kardiol Pol        ISSN: 0022-9032            Impact factor:   3.108


  3 in total

1.  R/S Ratio Variability in Lead V1 Observed between Selected Four 1-Minute ECG Fragments of 24-Hour ECG as a Predictor of Incomplete Resynchronization during Full 24-Hour ECG: Pilot Study.

Authors:  Dominika Pyszno-Prokopowicz; Rafał Baranowski; Robert Bodalski; Magdalena Madej; Ryszard Piotrowicz
Journal:  Ann Noninvasive Electrocardiol       Date:  2015-10-30       Impact factor: 1.468

2.  Shenxian-Shengmai Oral Liquid Improves Sinoatrial Node Dysfunction through the PKC/NOX-2 Signaling Pathway.

Authors:  Heng Zhang; Miao Hao; Lingkang Li; Keyan Chen; Jing Qi; Wei Chen; Xintong Cai; Chen Chen; Zhuang Liu; Ping Hou
Journal:  Evid Based Complement Alternat Med       Date:  2021-04-10       Impact factor: 2.629

3.  NRF-2/HO-1 Pathway-Mediated SHOX2 Activation Is a Key Switch for Heart Rate Acceleration by Yixin-Fumai Granules.

Authors:  Heng Zhang; Chen Chen; Yue Liu; Lu Ren; Jing Qi; Yang Yang; Wei Chen; Yingjia Yao; Xintong Cai; Zhuang Liu; Miao Hao; Lingkang Li; Zisu Deng; Mingyu Sun; Yongping Lu; Keyan Chen; Ping Hou
Journal:  Oxid Med Cell Longev       Date:  2022-09-26       Impact factor: 7.310

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.