Literature DB >> 26511634

Allogeneic and Autogenous Bone Grafts Are Affected by Historical Donor Environmental Exposure.

Caleb Behrend1, Jonathon Carmouche2, Paul W Millhouse3, Lauren Ritter4, Joseph Moskal2, Paul Rubery5, Edward Puzas5.   

Abstract

BACKGROUND: Bone graft materials are routinely evaluated for infectious agents; however, data regarding contamination of bone graft from environmental exposure of the donors to osteotoxic substances such as lead are not routinely available. In animal models, stored lead in bone has been shown to impair fracture healing and osteocyte function. In clinical studies, lead is linked to skeletal disease at relatively low concentrations. Presumably the levels of lead in allografts mirror the level of lead in bone in the population; however, the degree to which processing might decrease this and the frequency with which potentially osteotoxic levels appear in bone grafts have not been studied. QUESTIONS/PURPOSES: (1) Does processing of donor bone for allografts result in lower concentrations of lead in commercial allograft when compared with autologous bone graft; and (2) what proportion of bone grafts contain potentially osteotoxic levels of lead from > 2.0 to 20.0 µg/g corresponding to environmental exposure?
METHODS: Allograft from commercial sources and autologous bone graft materials were examined for lead content using ICP- atomic absorption spectrophotometric analysis. We analyzed bone graft specimens from 42 donors, including 26 corticocancellous tibial specimens from commercially available bone graft materials and 16 autograft corticocancellous tibial specimens. Lead levels were determined for the cortical (n = 42) and cancellous (n = 42) portions of each specimen. For quality control, all instruments, plastic and glassware, were regularly tested for lead contamination by atomic absorption spectrophotometry throughout the experiments. In addition, spectrophotometer calibration was verified using Standard Reference Material 1486 bone meal (NIST, Gaithersburg, MD, USA). Descriptive statistical analysis was performed using SPSS 20 (SPSS Inc, Chicago, IL, USA). Using these techniques, a lead level > 2 µg/g to 20 µg/g corresponds to some degree of environmental exposure to lead.
RESULTS: With the numbers available in the present study, there were no differences in mean lead level between commercial bone graft materials and autogenous bone graft, 2.1 µg/g (95% confidence interval [CI], 1.6-3.3 µg/g) versus 2.0 µg/g (95% CI, 1.0-4.5 µg/g; p = 0.86). The range for all tested samples varied from < 0.1 to 5.0 µg/g. Likewise, there were no differences in mean lead level between cortical bone grafts, which contained 2.2 µg/g (95% CI, 1.5-3.7 µg/g), and cancellous grafts, which contained 1.9 µg/g (95% CI, 1.2-3.4 µg/g; p = 0.58). Thirty-eight percent (16 of 42) of the specimens had levels between 2.0 µg/g and 20 µg/g within a range expected for individuals with known environmental exposure to lead.
CONCLUSIONS: This study demonstrates that lead is present in up to one-third of tibial allograft and autograft bone specimens at potentially osteotoxic levels regardless of the source or screening. Further research is needed to delineate the relationship with nonunion or pseudoarthrosis after procedures in which allograft is used. In addition, further study would examine concentrations of lead and other environmental contaminants in other graft types. CLINICAL RELEVANCE: Comparable levels of lead exposure have been associated with toxic effects on skeletal tissue. Further study of bone graft used in fusion procedures and other procedures is necessary to define the magnitude of osteotoxic effects in the setting of fracture care or fusion procedures.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26511634      PMCID: PMC4868162          DOI: 10.1007/s11999-015-4572-7

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  19 in total

1.  Bone lead levels and delinquent behavior.

Authors:  J A Hoppin; P B Ryan; H Hu; A C Aro
Journal:  JAMA       Date:  1996-06-12       Impact factor: 56.272

2.  Effects of lead on the somatic growth of children.

Authors:  A Kafourou; G Touloumi; V Makropoulos; A Loutradi; A Papanagiotou; A Hatzakis
Journal:  Arch Environ Health       Date:  1997 Sep-Oct

3.  Lead impairs the production of osteocalcin by rat osteosarcoma (ROS 17/2.8) cells.

Authors:  G J Long; J F Rosen; J G Pounds
Journal:  Toxicol Appl Pharmacol       Date:  1990-11       Impact factor: 4.219

Review 4.  Metal-bone interactions.

Authors:  M Berglund; A Akesson; P Bjellerup; M Vahter
Journal:  Toxicol Lett       Date:  2000-03-15       Impact factor: 4.372

5.  Effects of lead on growth plate chondrocyte phenotype.

Authors:  D G Hicks; R J O'Keefe; K J Reynolds; D A Cory-Slechta; J E Puzas; A Judkins; R N Rosier
Journal:  Toxicol Appl Pharmacol       Date:  1996-09       Impact factor: 4.219

6.  Comparison of concentrations of lead and cadmium in various parts of the femur head in patients after arthroplasty of the hip joint in Northwest Poland.

Authors:  Natalia Lanocha; Elzbieta Kalisińska; Danuta Kosik-Bogacka; Halina Budis; Sebastian Sokołowski; Andrzej Bohatyrewicz
Journal:  Biomed Environ Sci       Date:  2012-10       Impact factor: 3.118

7.  The effect of environmental factors on concentration of trace elements in hip joint bones of patients after hip replacement surgery.

Authors:  Natalia Lanocha; Ezbieta Kalisinska; Danuta I Kosik-Bogacka; Halina Budis; Sebastian Sokolowski; Andrzej Bohatyrewicz; Aleksandra Lanocha
Journal:  Ann Agric Environ Med       Date:  2013       Impact factor: 1.447

Review 8.  Cellular and molecular toxicity of lead in bone.

Authors:  J G Pounds; G J Long; J F Rosen
Journal:  Environ Health Perspect       Date:  1991-02       Impact factor: 9.031

9.  Heavy metal lead exposure, osteoporotic-like phenotype in an animal model, and depression of Wnt signaling.

Authors:  Eric E Beier; Jason R Maher; Tzong-Jen Sheu; Deborah A Cory-Slechta; Andrew J Berger; Michael J Zuscik; J Edward Puzas
Journal:  Environ Health Perspect       Date:  2012-10-19       Impact factor: 9.031

10.  The association between environmental lead exposure and bone density in children.

Authors:  James R Campbell; Randy N Rosier; Leonore Novotny; J Edward Puzas
Journal:  Environ Health Perspect       Date:  2004-08       Impact factor: 9.031

View more
  3 in total

1.  BMSC-Exosomes Carry Mutant HIF-1α for Improving Angiogenesis and Osteogenesis in Critical-Sized Calvarial Defects.

Authors:  Chenting Ying; Rui Wang; Zhenlin Wang; Jie Tao; Wenjing Yin; Jieyuan Zhang; Chengqing Yi; Xin Qi; Dan Han
Journal:  Front Bioeng Biotechnol       Date:  2020-11-19

Review 2.  Functionalization of Synthetic Bone Substitutes.

Authors:  André Busch; Marcus Jäger; Constantin Mayer; Andrea Sowislok
Journal:  Int J Mol Sci       Date:  2021-04-23       Impact factor: 5.923

Review 3.  Mesenchymal Stem Cell-Derived Extracellular Vesicles for Bone Defect Repair.

Authors:  Dongxue Wang; Hong Cao; Weizhong Hua; Lu Gao; Yu Yuan; Xuchang Zhou; Zhipeng Zeng
Journal:  Membranes (Basel)       Date:  2022-07-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.