Literature DB >> 26503401

Fast macromolecular proton fraction mapping of the human liver in vivo for quantitative assessment of hepatic fibrosis.

Vasily L Yarnykh1,2, Erica V Tartaglione3, George N Ioannou3,4.   

Abstract

The macromolecular proton fraction (MPF) is a quantitative MRI parameter determining the magnetization transfer (MT) effect in tissues, and is defined as the relative amount of immobile macromolecular protons involved in magnetization exchange with mobile water protons. MPF has the potential to provide a quantitative assessment of fibrous tissue because of the intrinsically high MPF specific for collagen. The goal of this study was to investigate the relationship between histologically determined fibrosis stage and MPF in the liver parenchyma measured using a recently developed fast single-point clinically targeted MPF mapping method. Optimal saturation parameters for single-point liver MPF measurements were determined from the analysis of liver Z spectra in vivo based on the error propagation model. Sixteen patients with chronic hepatitis C viral infection underwent 3-T MRI using an optimized liver MPF mapping protocol. Fourteen patients had prior liver biopsy with histologically staged fibrosis (METAVIR scores F0-F3) and two patients had clinically diagnosed cirrhosis (score F4 was assigned). The protocol included four breath-hold three-dimensional scans with 2 × 3 × 6-mm(3) resolution and 10 transverse sections: dynamic acquisition of MT-weighted and reference images; dynamic acquisition of three images for variable flip angle T1 mapping; dual-echo B0 map; and actual flip angle imaging B1 map. The average liver MPF was determined as the mode of the MPF histograms. MPF was significantly increased in patients with clinically significant fibrosis (scores F2-F4, n = 6) relative to patients with no or mild fibrosis (scores F0-F1, n = 10): 6.49 ± 0.36% versus 5.94 ± 0.26%, p < 0.01 (Mann-Whitney test). MPF and fibrosis scores were strongly positively correlated, with a Spearman's rank correlation coefficient of 0.80 (p < 0.001). This study demonstrates the feasibility of fast MPF mapping of the human liver in vivo and confirms the hypothesis that MPF is increased in hepatic fibrosis and associated with fibrosis stage. MPF may be useful as a non-invasive imaging biomarker of hepatic fibrosis.
Copyright © 2015 John Wiley & Sons, Ltd.

Entities:  

Keywords:  biomarker; fibrosis; hepatobiliary; macromolecular proton fraction; magnetization transfer; quantification

Mesh:

Substances:

Year:  2015        PMID: 26503401      PMCID: PMC4715674          DOI: 10.1002/nbm.3437

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  67 in total

Review 1.  Liver biopsy.

Authors:  A A Bravo; S G Sheth; S Chopra
Journal:  N Engl J Med       Date:  2001-02-15       Impact factor: 91.245

2.  Pulsed Z-spectroscopic imaging of cross-relaxation parameters in tissues for human MRI: theory and clinical applications.

Authors:  Vasily L Yarnykh
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

3.  Method for quantitative imaging of the macromolecular 1H fraction in tissues.

Authors:  Stefan Ropele; Thomas Seifert; Christian Enzinger; Franz Fazekas
Journal:  Magn Reson Med       Date:  2003-05       Impact factor: 4.668

4.  Magnetization transfer contrast imaging of liver cirrhosis.

Authors:  J H Chen; J W Chai; W C Shen
Journal:  Hepatogastroenterology       Date:  1999 Sep-Oct

5.  Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection.

Authors:  Arie Regev; Mariana Berho; Lennox J Jeffers; Clara Milikowski; Enrique G Molina; Nikolaos T Pyrsopoulos; Zheng-Zhou Feng; K Rajender Reddy; Eugene R Schiff
Journal:  Am J Gastroenterol       Date:  2002-10       Impact factor: 10.864

6.  Evaluation of liver diseases via MTC and contrast agent.

Authors:  J H Chen; H N Yeung; S K Lee; J W Chai
Journal:  J Magn Reson Imaging       Date:  1999-02       Impact factor: 4.813

7.  Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI.

Authors:  J G Sled; G B Pike
Journal:  Magn Reson Med       Date:  2001-11       Impact factor: 4.668

8.  A simple noninvasive index can predict both significant fibrosis and cirrhosis in patients with chronic hepatitis C.

Authors:  Chun-Tao Wai; Joel K Greenson; Robert J Fontana; John D Kalbfleisch; Jorge A Marrero; Hari S Conjeevaram; Anna S-F Lok
Journal:  Hepatology       Date:  2003-08       Impact factor: 17.425

9.  A multicenter measurement of magnetization transfer ratio in normal white matter.

Authors:  I Berry; G J Barker; F Barkhof; A Campi; V Dousset; J M Franconi; A Gass; W Schreiber; D H Miller; P S Tofts
Journal:  J Magn Reson Imaging       Date:  1999-03       Impact factor: 4.813

10.  Precise estimate of fundamental in-vivo MT parameters in human brain in clinically feasible times.

Authors:  A Ramani; C Dalton; D H Miller; P S Tofts; G J Barker
Journal:  Magn Reson Imaging       Date:  2002-12       Impact factor: 2.546

View more
  6 in total

Review 1.  Skeletal Muscle Quantitative Nuclear Magnetic Resonance Imaging and Spectroscopy as an Outcome Measure for Clinical Trials.

Authors:  Pierre G Carlier; Benjamin Marty; Olivier Scheidegger; Paulo Loureiro de Sousa; Pierre-Yves Baudin; Eduard Snezhko; Dmitry Vlodavets
Journal:  J Neuromuscul Dis       Date:  2016-03-03

2.  Resolving estimation uncertainties of chemical shift encoded fat-water imaging using magnetization transfer effect.

Authors:  Alexey Samsonov; Fang Liu; Julia V Velikina
Journal:  Magn Reson Med       Date:  2019-03-07       Impact factor: 4.668

3.  High-resolution three-dimensional macromolecular proton fraction mapping for quantitative neuroanatomical imaging of the rodent brain in ultra-high magnetic fields.

Authors:  Anna V Naumova; Andrey E Akulov; Marina Yu Khodanovich; Vasily L Yarnykh
Journal:  Neuroimage       Date:  2016-09-17       Impact factor: 6.556

4.  Quantitative Magnetization Transfer Imaging of the Breast at 3.0 T: Reproducibility in Healthy Volunteers.

Authors:  Lori R Arlinghaus; Richard D Dortch; Jennifer G Whisenant; Hakmook Kang; Richard G Abramson; Thomas E Yankeelov
Journal:  Tomography       Date:  2016-12

5.  Sensitive detection of extremely small iron oxide nanoparticles in living mice using MP2RAGE with advanced image co-registration.

Authors:  Joong H Kim; Stephen Dodd; Frank Q Ye; Andrew K Knutsen; Duong Nguyen; Haitao Wu; Shiran Su; Simone Mastrogiacomo; Thomas J Esparza; Rolf E Swenson; David L Brody
Journal:  Sci Rep       Date:  2021-01-08       Impact factor: 4.996

6.  Magnetization Transfer Ratio in Lower Limbs of Late Onset Pompe Patients Correlates With Intramuscular Fat Fraction and Muscle Function Tests.

Authors:  Claudia Nuñez-Peralta; Paula Montesinos; Alicia Alonso-Jiménez; Jorge Alonso-Pérez; David Reyes-Leiva; Javier Sánchez-González; Jaume Llauger-Roselló; Sonia Segovia; Izaskun Belmonte; Irene Pedrosa; Antonio Martínez-Noguera; Briano Matellini-Mosca; Glenn Walter; Jordi Díaz-Manera
Journal:  Front Neurol       Date:  2021-03-16       Impact factor: 4.003

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.