INTRODUCTION: Management of high grade proximal tibia or tibial plateau fractures is often associated with complications. The use of wire fixators for the definitive treatment of such fractures entails a minimally invasive technique of insertion that gives good fracture reduction and stability combined with minimal postoperative complications. AIM: To assess the outcome of treatment of such fractures by the use of Joshi's external stabilization system (JESS), which is a wire based, circular external fixator system.
MATERIALS AND METHODS: A prospective, uncontrolled study was done using JESS on 20 consecutive patients of high energy fractures of the tibial plateau, classified according to the Schatzker's classification as type VI.
RESULTS: In this series, road traffic accidents accounted for most of the injuries (n=12), while pedestrian accidents (n=4), injury due to fall from height (n=3) and injury due to fall while playing (n=1) were the other modes of injury. The mean patient age was 39.4 years. The mean follow up period was 24 weeks. In this study, using Knee society score evaluation, excellent results were seen in 12 patients (60%), good results were seen in 5 patients (25%), fair in 2 patients (10%) and bad in 1 patient (5%). Complications seen were, pin tract infections in two cases (10%) which resolved with dressings and oral antibiotics and one case of non-union (5%), in which the tibial plateau fracture extended into proximal 1/3 of the tibial shaft with severe comminution. No other complication was encountered.
CONCLUSION: JESS is a simple, inexpensive and useful technique in the management of high grade tibial plateau fractures.

Entities:  

Keywords:  Bicondylar; JESS; Schatzker; Tibial plateau

Year:  2015        PMID: 26500969      PMCID: PMC4606298          DOI: 10.7860/JCDR/2015/15626.6513

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  16 in total

1.  High energy tibial plateau fractures treated with hybrid external fixation.

Authors:  George C Babis; Dimitrios S Evangelopoulos; Panagiotis Kontovazenitis; Konstantinos Nikolopoulos; Panagiotis N Soucacos
Journal:  J Orthop Surg Res       Date:  2011-07-14       Impact factor: 2.359

2.  Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system.

Authors:  S Asif; D S K Choon
Journal:  J Orthop Surg (Hong Kong)       Date:  2005-12       Impact factor: 1.118

3.  Treatment of high-energy tibial plateau fractures by the Ilizarov circular fixator.

Authors:  G K Dendrinos; S Kontos; D Katsenis; A Dalas
Journal:  J Bone Joint Surg Br       Date:  1996-09

4.  Rationale of the Knee Society clinical rating system.

Authors:  J N Insall; L D Dorr; R D Scott; W N Scott
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

5.  Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures. Results of a multicenter, prospective, randomized clinical trial.

Authors: 
Journal:  J Bone Joint Surg Am       Date:  2006-12       Impact factor: 5.284

6.  [Use of a hybrid external fixator for treatment of tibial fractures].

Authors:  J Zeman; J Matejka
Journal:  Acta Chir Orthop Traumatol Cech       Date:  2005       Impact factor: 0.531

7.  Treatment strategies for complex fractures of the tibial plateau with external circular fixation and limited internal fixation.

Authors:  Maurizio A Catagni; Giulia Ottaviani; Massimiliano Maggioni
Journal:  J Trauma       Date:  2007-11

8.  Complications of high-energy bicondylar tibial plateau fractures treated with dual plating through 2 incisions.

Authors:  Michael R Ruffolo; Franklin K Gettys; Harvey E Montijo; Rachel B Seymour; Madhav A Karunakar
Journal:  J Orthop Trauma       Date:  2015-02       Impact factor: 2.512

9.  Combination of fine wire fixation and limited internal fixation for high-energy tibial plateau fractures: functional results at minimum 5-year follow-up.

Authors:  Dimitris Katsenis; George Dendrinos; Antonis Kouris; Nikos Savas; Nikos Schoinochoritis; Kostas Pogiatzis
Journal:  J Orthop Trauma       Date:  2009-08       Impact factor: 2.512

10.  Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures. Surgical technique.

Authors:  Jeremy A Hall; Murray J Beuerlein; Michael D McKee
Journal:  J Bone Joint Surg Am       Date:  2009-03-01       Impact factor: 5.284

View more
  2 in total

1.  Complex Tibial Plateau Fractures Treated by Hybrid External Fixation System: A correlation of followup computed tomography derived quality of reduction with clinical results.

Authors:  Konstantinos Kateros; Spyridon P Galanakos; Georgios Kyriakopoulos; Stamatios A Papadakis; George A Macheras
Journal:  Indian J Orthop       Date:  2018 Mar-Apr       Impact factor: 1.251

2.  Prevalence of Deep Surgical Site Infection After Repair of Periarticular Knee Fractures: A Systematic Review and Meta-analysis.

Authors:  Grayson R Norris; Jake X Checketts; Jared T Scott; Matt Vassar; Brent L Norris; Peter V Giannoudis
Journal:  JAMA Netw Open       Date:  2019-08-02
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.