Literature DB >> 21756337

High energy tibial plateau fractures treated with hybrid external fixation.

George C Babis1, Dimitrios S Evangelopoulos, Panagiotis Kontovazenitis, Konstantinos Nikolopoulos, Panagiotis N Soucacos.   

Abstract

Management of high energy intra-articular fractures of the proximal tibia, associated with marked soft-tissue trauma, can be challenging, requiring the combination of accurate reduction and minimal invasive techniques. The purpose of this study was to evaluate whether minimal intervention and hybrid external fixation of such fractures using the Orthofix system provide an acceptable treatment outcome with less complications. Between 2002 and 2006, 33 patients with a median ISS of 14.3 were admitted to our hospital, a level I trauma centre, with a bicondylar tibial plateau fracture. Five of them sustained an open fracture. All patients were treated with a hybrid external fixator. In 19 of them, minimal open reduction and stabilization, by means of cannulated screws, was performed. Mean follow-up was 27 months (range 24 to 36 months). Radiographic evidence of union was observed at 3.4 months (range 3 to 7 months). Time for union was different in patients with closed and grade I open fractures compared to patients with grade II and III open fractures. One non-union (septic) was observed (3.0%), requiring revision surgery. Pin track infection was observed in 3 patients (9.1%).Compared to previously reported series of conventional open reduction and internal fixation, hybrid external fixation with or without open reduction and minimal internal fixation with the Orthofix system, was associated with satisfactory clinical and radiographic results and limited complications.

Entities:  

Mesh:

Year:  2011        PMID: 21756337      PMCID: PMC3161896          DOI: 10.1186/1749-799X-6-35

Source DB:  PubMed          Journal:  J Orthop Surg Res        ISSN: 1749-799X            Impact factor:   2.359


  41 in total

1.  Internal versus external fixation of bicondylar tibial plateau fractures.

Authors:  A R Mallik; D J Covall; G P Whitelaw
Journal:  Orthop Rev       Date:  1992-12

2.  Treatment of high-energy tibial plateau fractures by the Ilizarov circular fixator.

Authors:  G K Dendrinos; S Kontos; D Katsenis; A Dalas
Journal:  J Bone Joint Surg Br       Date:  1996-09

3.  Rationale of the Knee Society clinical rating system.

Authors:  J N Insall; L D Dorr; R D Scott; W N Scott
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

4.  Bicondylar tibial plateau fractures: principles of treatment.

Authors:  D J Covall; C D Fowble; T E Foster; G P Whitelaw
Journal:  Contemp Orthop       Date:  1994-02

5.  Tibial fractures. The Ilizarov alternative.

Authors:  V Schwartsman; S N Martin; R A Ronquist; R Schwartsman
Journal:  Clin Orthop Relat Res       Date:  1992-05       Impact factor: 4.176

6.  Complications of internal fixation of tibial plateau fractures.

Authors:  M J Young; R L Barrack
Journal:  Orthop Rev       Date:  1994-02

7.  Ligament injuries associated with tibial plateau fractures.

Authors:  R B Delamarter; M Hohl; E Hopp
Journal:  Clin Orthop Relat Res       Date:  1990-01       Impact factor: 4.176

8.  Percutaneous screw fixation of tibial plateau fractures.

Authors:  P Keogh; C Kelly; W F Cashman; A J McGuinness; S K O'Rourke
Journal:  Injury       Date:  1992       Impact factor: 2.586

Review 9.  Tibial plateau fractures. Management and expected results.

Authors:  H Tscherne; P Lobenhoffer
Journal:  Clin Orthop Relat Res       Date:  1993-07       Impact factor: 4.176

10.  The use of combination internal fixation and hybrid external fixation in severe proximal tibia fractures.

Authors:  L S Weiner; M Kelley; E Yang; J Steuer; N Watnick; M Evans; M Bergman
Journal:  J Orthop Trauma       Date:  1995-06       Impact factor: 2.512

View more
  16 in total

1.  A clinico-radiological study of bicondylar tibial plateau fractures managed with dual locking plates.

Authors:  Virender Kumar; Mamta Singhroha; Kunal Arora; Ankur Sahu; Rajpal Beniwal; Ankush Kundu
Journal:  J Clin Orthop Trauma       Date:  2021-08-12

2.  Clinical and radiological significance of posteromedial fragment in tibial plateau fractures.

Authors:  Mehmet Akdemir; Mehmet Aykut Türken; Ahmet Cemil Turan; Ahmet Çağdaş Biçen; Ali İhsan Kılıç
Journal:  J Orthop       Date:  2022-04-25

3.  Early diagnosis and treatment of trauma in knee joints accompanied with popliteal vascular injury.

Authors:  Yun-Qin Xu; Qiang Li; Tu-Gang Shen; Pei-Hua Su; Ya-Zhong Zhu
Journal:  Int J Clin Exp Med       Date:  2015-06-15

Review 4.  High-energy tibial plateau fractures: external fixation versus plate fixation.

Authors:  Liang Yu; Zhong Fenglin
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-09-13

5.  Management of Proximal Tibia Fractures Using Wire Based Circular External Fixator.

Authors:  Harpreet Singh; Rakesh Kumar Misra; Manjinder Kaur
Journal:  J Clin Diagn Res       Date:  2015-09-01

6.  Outcome of complex tibial plateau fractures treated with external fixator.

Authors:  Sushil H Mankar; Anil V Golhar; Mayank Shukla; Prashant S Badwaik; Mohammad Faizan; Sameer Kalkotwar
Journal:  Indian J Orthop       Date:  2012-09       Impact factor: 1.251

7.  GIT1 gene deletion delays chondrocyte differentiation and healing of tibial plateau fracture through suppressing proliferation and apoptosis of chondrocyte.

Authors:  Peng Chen; Wan-Li Gu; Ming-Zhi Gong; Jun Wang; Dong-Qing Li
Journal:  BMC Musculoskelet Disord       Date:  2017-07-28       Impact factor: 2.362

8.  Results of ring (Ilizarov) fixator in high energy Schatzker type VI fractures of proximal tibia.

Authors:  Ujjwal Kanti Debnath; Dipak Kumar Jha; Prasanta Kumar Pujari
Journal:  J Clin Orthop Trauma       Date:  2017-08-31

9.  Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study.

Authors:  Xiaowei Huang; Zhongzheng Zhi; Baoqing Yu; Fancheng Chen
Journal:  J Orthop Surg Res       Date:  2015-11-25       Impact factor: 2.359

10.  Outcome of angular stable locking plate fixation of tibial plateau fractures Midterm results in 101 patients.

Authors:  Sven Märdian; Felix Landmann; Florian Wichlas; Norbert P Haas; Klaus-Dieter Schaser; Philipp Schwabe
Journal:  Indian J Orthop       Date:  2015 Nov-Dec       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.