INTRODUCTION: Traumatic eye injuries (TEI) involved about 3% of cases referred to the emergency departments of developing countries. Lens dislocation is one of the critical cases of ophthalmic emergencies. The present study was aimed to evaluate the diagnostic accuracy of ultrasonography in detection of traumatic lens dislocation. METHODS: In this cross-sectional study the findings of ultrasonography and orbital computed tomography (OCT) of head and face trauma patients, referred to Imam Reza hospital, Tabriz, Iran, from July 2013 to June 2014, have been compared. The sensitivity, specificity, positive and negative likelihood ratio, positive and negative predictive value, and accuracy of ultrasonography were calculated. Cohen's kappa coefficient was presented to assess the agreement of ultrasonography with OCT findings. RESULTS: One hundred thirty patients with the mean age of 35.4±18.0 were evaluated (75.4% male). Sensitivity and specificity of ultrasonography were 84.6% (95% Cl: 53.7-97.3) and 98.3% (95% Cl: 93.3- 99.7), respectively. In addition, positive and negative likelihood ratio were calculated 49.5 (95% Cl: 12.3-199.4) and 0.15 (95% Cl: 0.04- 0.56), respectively. Cohen's kappa coefficient of 0.83 (95% Cl: 0.66-1.0; p<0.0001) was representative of excellent agreement of these two tests. CONCLUSION: The finding of this project was representative of 84.6% sensitivity, 98.3% specificity, and 96.9% accuracy of ultrasonography in detection of traumatic lens dislocation. It seems that in cases, which OCT is not possible, ultrasonography, could be an acceptable option to assess traumatic eye injuries.
INTRODUCTION:Traumatic eye injuries (TEI) involved about 3% of cases referred to the emergency departments of developing countries. Lens dislocation is one of the critical cases of ophthalmic emergencies. The present study was aimed to evaluate the diagnostic accuracy of ultrasonography in detection of traumatic lens dislocation. METHODS: In this cross-sectional study the findings of ultrasonography and orbital computed tomography (OCT) of head and face traumapatients, referred to Imam Reza hospital, Tabriz, Iran, from July 2013 to June 2014, have been compared. The sensitivity, specificity, positive and negative likelihood ratio, positive and negative predictive value, and accuracy of ultrasonography were calculated. Cohen's kappa coefficient was presented to assess the agreement of ultrasonography with OCT findings. RESULTS: One hundred thirty patients with the mean age of 35.4±18.0 were evaluated (75.4% male). Sensitivity and specificity of ultrasonography were 84.6% (95% Cl: 53.7-97.3) and 98.3% (95% Cl: 93.3- 99.7), respectively. In addition, positive and negative likelihood ratio were calculated 49.5 (95% Cl: 12.3-199.4) and 0.15 (95% Cl: 0.04- 0.56), respectively. Cohen's kappa coefficient of 0.83 (95% Cl: 0.66-1.0; p<0.0001) was representative of excellent agreement of these two tests. CONCLUSION: The finding of this project was representative of 84.6% sensitivity, 98.3% specificity, and 96.9% accuracy of ultrasonography in detection of traumatic lens dislocation. It seems that in cases, which OCT is not possible, ultrasonography, could be an acceptable option to assess traumatic eye injuries.
Traumatic eye injuries (TEI) involved about 3% of cases visited in emergency departments (ED) of developing countries (1). It is estimated that trauma causes blindness and visual impairment in many referees of ophthalmic emergency (2). Most of these injuries are hard to diagnose in initial ED assessment. On the other hand, more frequent examinations to detect injuries maybe hazardous for the patient (3). Orbital computed tomography (OCT) scan, magnetic resonance imaging (MRI), ultrasonography, and slit-lamp are introduced as the most important imaging tools to evaluate TEI (4-8). Although MRI presents high accurate and quality images, it is an expensive and time-consuming test, which is not accessible in all emergency centers. Optical methods are cost effective and easy to use, but they have a low accuracy in evaluation of injuries to optical structures such as sclera, pupil, and cornea, as well as hemorrhage. While ultrasonography, known as a non-expensive, accessible, and safe method, has a high accuracy in evaluation of injuries to optical structures (3). When the patient is non-cooperative for fundoscopic tests or suffers from severe edema, chemosis, or hyphema, eye ultrasonography can present valuable and useful information to the physician (9). But, it should be mentioned that diagnostic accuracy of ultrasonography is highly dependent to operator proficiency and it is not reliable in detecting parenchymal injuries (10). Lens dislocation is one of the critical cases of ophthalmic emergencies referred to partial or complete dislocation of eye lens from its natural location to posterior chamber. Trauma is one of the most common reasons of lens dislocation (11). The fast diagnosis of such an injury can be greatly help improving the patients' outcomes. Diagnostic accuracy of ultrasonography in assessment of traumatic lens dislocation is evaluated in a few studies. Whereas some of investigations suggested OCT as an accurate method (12), others consider ultrasonography as a valuable diagnostic tool in detection of lens dislocation, especially in lack of OCT (13-16). However, the low number of studied samples in this field is the critical limitation. Therefore, the present study was performed to evaluate the diagnostic value of ultrasonography versus OCT in traumatic lens dislocation.
Methods:
In this cross-sectional study the findings of ultrasonography and OCT of multiple traumapatient with head trauma, referred to Imam Reza hospital, Tabriz, Iran, from July 2013 to June 2014, have been compared. Data collection and ultrasonography was done by an emergency medicine specialist. OCTs (as a gold standard tool) were interpreted by a radiologist who was blind to the aim of study. The protocol of the present project was studied and confirmed by the ethical committee of Tabriz University of Medical Sciences. All researchers adhered the Helsinki declaration during the study. The study protocol did not have any interference with treatment process and no danger threatened patients. The collected forms were anonymous and for each patient an especial code registered. Before the study, patients filled the personal consent form.In this study, multiple traumapatients with TEI were entered. Patients with irregularity of the globe contour, and lack of ability to cooperate for imaging were excluded from the study. Sample selection was sequentially. For determining of the sample volume, the least needed samples were achieved 121 persons noticing to at least 93% sensitivity of ultrasonography to detect TEI, 15% prevalence (12), 95% confidence interval (α=0.05), 90% power (β= 0.1), and maximum error of 1% (d= 0.01).The emergency medicine specialist was prospectively assessed demographic data (age, sex, and trauma mechanism), clinical symptoms of each patient, and registered them in data gathering form. Then, the patients underwent eye ultrasonography by a trained emergency medicine specialist. Ultrasonography was done using bedside machine (GH Healthcare; LOGIQ 200, PRO series; Korea) with 10 MHz micro-convex linear transducer in sagittal and transverse plane and closed eye technique with water-soluble gel. Then patients referred to ED radiology unit for performing OCT. The findings of OCT was interpreted by a radiologist blind to the goal of study and recorded. OCT was done using a Toshiba Asteion 16 slices scanner with considering the one-millimeter distance between image slices. Both ultrasonography and OCT was performed in recumbent position.Data were entered to SPSS version 21.0 and imaging findings reported as the frequency and percentage. For evaluating the quality of ultrasonography receiver operating characteristic (ROC) curve was drown and finally sensitivity, specificity, accuracy, positive likelihood ratio, negative likelihood ratio, positive predictive value, and negative predictive value calculated. Cohen's kappa coefficient was presented to assess the agreement of ultrasonography with OCT findings. P<0.05 was considered as a significant level.The receiver operating characteristic (ROC) curve of ultrasonography in detection of traumatic lens dislocationClinical and demographic characteristics of studied patientsDiagnostic accuracy of ultrasonography in detection of traumatic lens dislocationCI: confidence interval
Results:
130 patients with the mean age of 35.4±18.0 were entered to the study (75.4% male). Five patients (3.8%) had systolic blood pressure below 90 and 32 ones (24.6%) suffered from tachycardia. GCS of 21 patients (16.15%) was below nine and in 35 ones (26.9%) within 9-13 (Table 1). The most common mechanism of accident in the patients was related to car (39.2%), motorcycle (27.7%), and pedestrian accidents (15.4%), respectively.
Table 1
Clinical and demographic characteristics of studied patients
Clinical characteristic
Frequency (%)
Gender
Male
32 (24.6)
Female
98 (75.4)
Hypotension
No
125 (96.2)
Yes
5 (3.8)
Glasgow Coma Scale
14-15
74 (56.9)
9-13
35 (26.9)
3-9
21 (16.2)
Mechanism
Pedestrian
20 (15.4)
Car (driver)
51 (39.2)
Motorcycle (driver)
36 (27.7)
Falling
8 (6.15)
Intentional injuries
7 (5.4)
Other
8 (6.15)
Visual accuracy
Normal
57 (43.85)
Abnormal
8 (6.15)
No cooperation
65 (50.0)
Laceration
No
73 (56.15)
Yes
57 (43.85)
Ecchymosis
No
17 (13.1)
Yes
113 (89.9)
Eye bleeding
No
128 (98.5)
Yes
2(1.5)
Globe Rupture
No
124 (95.4)
Yes
6 (4.6)
Periorbital edema
NO
67 (51.5)
Yes
63 (48.5)
OCT evaluation has detected 13 cases (10%) of traumatic lens dislocation. The findings of ultrasonography in 11 cases were compatible with OCT with two false negative cases, while two false positive were found by ultrasonography. The area under the ROC curve of ultrasonography in traumatic lens dislocation was achieved 0.9145 (95% Cl: 0.81-1.0) (Figure 1). Sensitivity and specificity of ultrasonography were 84.6% (95% Cl: 53.7-97.3) and 98.3% (95% Cl: 93.3- 99.7), respectively. Positive and negative likelihood ratio of this diagnostic test in detection of lens dislocation were calculated 49.5 (95% Cl: 12.3-199.4) and 0.15 (95% Cl: 0.04- 0.56), respectively (Table 2). Cohen's kappa coefficient of 0.83 (95% Cl: 0.66-1.0; p<0.0001) was representative of excellent agreement of these two tests.
Figure 1
The receiver operating characteristic (ROC) curve of ultrasonography in detection of traumatic lens dislocation
Table 2
Diagnostic accuracy of ultrasonography in detection of traumatic lens dislocation
Value
Rate (95% CI)
Sensitivity
84.6 (53.7-97.3)
Specificity
98.3 (93.3-99.7)
Positive predictive value
84.6 (53.7-97.3)
Negative predictive value
98.3 (93.3-99.7)
Positive likelihood Ratio
49.5 (12.3-199.4)
Negative likelihood Ratio
0.15 (0.04-0.56)
Accuracy
96.9 (93.9-99-9)
CI: confidence interval
Discussion:
The findings of the present study showed 84.6% sensitivity and 98.3% specificity of eye ultrasonography in detection of traumatic lens dislocation. The accuracy of this diagnostic test was 96.9%. Based on these results, it seems that in cases, which OCT is not possible, ultrasonography, could be an acceptable alternative for evaluation of lens dislocation.There are a few study assessed the diagnostic value of ultrasonography in detection of lens dislocation. Imran et al. revealed that sensitivity and specificity of ultrasonography are 75% and 97.9% in diagnosis of lens dislocation, respectively (12). Blavis and colleagues by study of 61 patients observed two cases of lens dislocation both of which was detected by ultrasonography (13). The trivial difference between previous studies and the present project could be due to operator-dependent of ultrasonography. On the other hand, reaching a certain diagnosis is time consuming and ophthalmic consultants are not present in all hospitals. All of these issues maybe lead to delay in detection and management whereas eye ultrasonography can be helpful in such situations. However, eye ultrasonography has not yet common in ophthalmic clinicians. In addition, eye ultrasound transducers for eye ultrasonography are different from common transducers applied in the ED (13). In addition, it should be mentioned that clinical evaluation of patients with TEI is painful and not possible in many cases.Although there is no information regarding the negative effect of entered energy by high frequency ultrasonography on eye structures, more investigation is required in this area. One of the limited studies in this field revealed that using ultrasonography with frequency of 10 to 60 MHz did not have any destructive effects on visual field and histological findings. But, the recent study showed that using ultrasonography causes to increase the internal temperature of eye (17). However, researchers expressed that this test should be used preciously until finding appropriate solutions to the above problems.
Conclusion:
The finding of this project was representative of 84.6% sensitivity, 98.3% specificity, and 96.9% accuracy of ultrasonography in detection of traumatic lens dislocation. It seems that in cases, which OCT is not possible, ultrasonography, could be an acceptable option to assess traumatic eye injuries.