Glenoid Bone-Grafting in Revision to a Reverse Total Shoulder Arthroplasty.

Eric Wagner1, Matthew T Houdek1, Timothy Griffith1, Bassem T Elhassan1, Joaquin Sanchez-Sotelo1, John W Sperling1, Robert H Cofield1.   

Abstract

BACKGROUND: Revision of a shoulder arthroplasty to a reverse shoulder arthroplasty in the presence of glenoid bone loss is especially challenging. The purpose of the present study was to determine the complications and results of glenoid bone-grafting in revision to a reverse shoulder arthroplasty.
METHODS: Between 2005 and 2010, 143 consecutive reverse shoulder arthroplasties performed as revision procedures were performed at our institution. Glenoid bone-grafting was performed in forty-one shoulders (29%), with 98% (forty) that had follow-up of more than two years (mean, 3.1 years). The 102 patients who did not undergo grafting served as a control group.
RESULTS: Seven patients (18%) required another revision surgery because of glenoid loosening (four patients), instability (two patients), or infection (one patient). The two and five-year implant survival rate free of revision for shoulders that had glenoid bone-grafting was 88% and 76%, respectively, which was lower than that for patients who had not required glenoid bone-grafting. The survival rate free of radiographic glenoid loosening at two and five years for the shoulders that had bone-grafting was 92% and 89%, respectively, which was worse than that for those that had not had glenoid bone-grafting. Patients had significant pain relief and improvement in their shoulder range of motion, and they had an increased level of satisfaction compared with the preoperative status. Increased rates of glenoid loosening were seen in patients who had an increased body mass index, an implant with a lateral center of rotation, a previous total shoulder replacement (versus hemiarthroplasty), and in those who were smokers.
CONCLUSIONS: Although there were relatively high rates of glenoid loosening and reoperation at mid-term follow-up, glenoid reconstruction with bone graft in the revision setting was able to relieve pain and restore shoulder function and stability.
Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

Entities:  

Mesh:

Year:  2015        PMID: 26491129     DOI: 10.2106/JBJS.N.00732

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  24 in total

1.  Expanding roles for reverse shoulder arthroplasty.

Authors:  Peter N Chalmers; Jay D Keener
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

2.  Benefits of a metallic lateralized baseplate prolonged by a long metallic post in reverse shoulder arthroplasty to address glenoid bone loss.

Authors:  Philippe Valenti; Johanna Sekri; Jean Kany; Imen Nidtahar; Jean-David Werthel
Journal:  Int Orthop       Date:  2018-11-30       Impact factor: 3.075

3.  Quantitative in vivo assessment of bone allograft viability using 18F-fluoride PET/CT after glenoid augmentation in reverse shoulder arthroplasty: a pilot study.

Authors:  Josef Hochreiter; Georg Mattiassich; Wolfgang Hitzl; Georg Weber; Mohsen Beheshti; Reinhold Ortmaier
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-06-06

4.  Assessment of anatomical and reverse total shoulder arthroplasty with the scapula-weighted Constant-Murley score.

Authors:  Giovanni Merolla; Ilaria Parel; Andrea Giovanni Cutti; Maria Vittoria Filippi; Paolo Paladini; Giuseppe Porcellini
Journal:  Int Orthop       Date:  2018-08-10       Impact factor: 3.075

5.  Revision shoulder arthroplasty with a reverse shoulder prosthesis : Use of structural allograft for glenoid bone loss.

Authors:  S E Ozgur; R Sadeghpour; T R Norris
Journal:  Orthopade       Date:  2017-12       Impact factor: 1.087

6.  Revision to Reverse Total Shoulder Arthroplasty Restores Stability for Patients With Unstable Shoulder Prostheses.

Authors:  Nicholas M Hernandez; Brian P Chalmers; Eric R Wagner; John W Sperling; Robert H Cofield; Joaquin Sanchez-Sotelo
Journal:  Clin Orthop Relat Res       Date:  2017-08-28       Impact factor: 4.176

7.  Customized tantalum-augmented reverse shoulder arthroplasty for glenoid bone defect and excessive medialization: description of the technique.

Authors:  Nicola Ivaldo; Tony Mangano; Giovanni Caione; Mario Rossoni; Angelo Ligas
Journal:  Musculoskelet Surg       Date:  2016-11-30

Review 8.  [Humeral and glenoid bone loss in shoulder arthroplasty : Classification and treatment principles].

Authors:  F Gohlke; B Werner
Journal:  Orthopade       Date:  2017-12       Impact factor: 1.087

9.  Planning software and patient-specific instruments in shoulder arthroplasty.

Authors:  James D Wylie; Robert Z Tashjian
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

10.  Reverse total shoulder arthroplasty using helical blade to optimize glenoid fixation and bone preservation: preliminary results in thirty five patients with minimum two year follow-up.

Authors:  Sebastien Zilber; Eleonora Camana; Peter Lapner; Emil Haritinian; Laurent Nove Josserand
Journal:  Int Orthop       Date:  2018-03-26       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.