Negative pressure wound therapy limits downgrowth in percutaneous devices.

Saranne J Mitchell1,2,3, Sujee Jeyapalina1,2,3, Francesca R Nichols1,2, Jayant Agarwal4, Kent N Bachus1,2,3.   

Abstract

Maintenance of a soft tissue seal around percutaneous devices is challenged by the downgrowth of periprosthetic tissues-a gateway to potential infection. As negative pressure wound therapy (NPWT) is used clinically to facilitate healing of complex soft tissue pathologies, it was hypothesized that NPWT could limit downgrowth of periprosthetic tissues. To test this hypothesis, 20 hairless guinea pigs were randomly assigned into four groups (n = 5/group). Using a One-Stage (Groups 1 and 3) or a Two-Stage (Groups 2 and 4) surgical procedure, each animal was implanted with a titanium-alloy subdermal device porous-coated with commercially pure, medical grade titanium. Each subdermal device had a smooth titanium-alloy percutaneous post. The One-Stage procedure encompassed insertion of a fully assembled device during a single surgery. The Two-Stage procedure involved the implantation of a subdermal device during the first surgery, and then three weeks later, insertion of a percutaneous post. Groups 1 and 2 served as untreated controls and Groups 3 and 4 received NPWT. Four weeks postimplantation of the post, the devices and surrounding tissues were harvested, and histologically evaluated for downgrowth. Within the untreated control groups, the Two-Stage surgical procedure significantly decreased downgrowth (p = 0.027) when compared with the One-Stage procedure. Independent of the surgical procedures performed, NPWT significantly limited downgrowth (p ≤ 0.05) when compared with the untreated controls.
© 2015 by the Wound Healing Society.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26487170      PMCID: PMC4805517          DOI: 10.1111/wrr.12373

Source DB:  PubMed          Journal:  Wound Repair Regen        ISSN: 1067-1927            Impact factor:   3.617


  37 in total

1.  Wound contraction in the guinea-pig.

Authors:  C A CHARLTON; D I HIGTON; D W JAMES; A R NICOL; J O STEWART
Journal:  Br J Surg       Date:  1961-07       Impact factor: 6.939

2.  Osseocutaneous integration of an intraosseous transcutaneous amputation prosthesis implant used for reconstruction of a transhumeral amputee: case report.

Authors:  Norbert V Kang; Catherine Pendegrass; Linda Marks; Gordon Blunn
Journal:  J Hand Surg Am       Date:  2010-06-11       Impact factor: 2.230

3.  The use of titanium and stainless steel in fracture fixation.

Authors:  J S Hayes; R G Richards
Journal:  Expert Rev Med Devices       Date:  2010-11       Impact factor: 3.166

4.  Transcutaneous, distal femoral, intramedullary attachment for above-the-knee prostheses: an endo-exo device.

Authors:  Horst Heinrich Aschoff; Robert E Kennon; John M Keggi; Lee E Rubin
Journal:  J Bone Joint Surg Am       Date:  2010-12       Impact factor: 5.284

Review 5.  Update on negative-pressure wound therapy.

Authors:  Dennis P Orgill; Lauren R Bayer
Journal:  Plast Reconstr Surg       Date:  2011-01       Impact factor: 4.730

6.  Organization of stem cells and their progeny in human epidermis.

Authors:  Soosan Ghazizadeh; Lorne B Taichman
Journal:  J Invest Dermatol       Date:  2005-02       Impact factor: 8.551

Review 7.  The mechanisms of action of vacuum assisted closure: more to learn.

Authors:  Dennis P Orgill; Ernest K Manders; Bauer E Sumpio; Raphael C Lee; Christopher E Attinger; Geoffrey C Gurtner; H Paul Ehrlich
Journal:  Surgery       Date:  2009-04-19       Impact factor: 3.982

8.  Outcome of percutaneous osseointegrated prostheses for patients with unilateral transfemoral amputation at two-year follow-up.

Authors:  Kerstin Hagberg; Elisabeth Hansson; Rickard Brånemark
Journal:  Arch Phys Med Rehabil       Date:  2014-07-24       Impact factor: 3.966

9.  Vacuum-assisted closure therapy increases local interleukin-8 and vascular endothelial growth factor levels in traumatic wounds.

Authors:  Ludwig Labler; Mario Rancan; Ladislav Mica; Luc Härter; Daniela Mihic-Probst; Marius Keel
Journal:  J Trauma       Date:  2009-03

Review 10.  Growth factors and cytokines in wound healing.

Authors:  Stephan Barrientos; Olivera Stojadinovic; Michael S Golinko; Harold Brem; Marjana Tomic-Canic
Journal:  Wound Repair Regen       Date:  2008 Sep-Oct       Impact factor: 3.617

View more
  4 in total

1.  Biomimetic coatings and negative pressure wound therapy independently limit epithelial downgrowth around percutaneous devices.

Authors:  Sujee Jeyapalina; Saranne J Mitchell; Jayant Agarwal; Kent N Bachus
Journal:  J Mater Sci Mater Med       Date:  2019-06-10       Impact factor: 3.896

2.  A 24-month evaluation of a percutaneous osseointegrated limb-skin interface in an ovine amputation model.

Authors:  Sujee Jeyapalina; James Peter Beck; Jayant Agarwal; Kent N Bachus
Journal:  J Mater Sci Mater Med       Date:  2017-10-04       Impact factor: 3.896

Review 3.  Junctional epithelium and hemidesmosomes: Tape and rivets for solving the "percutaneous device dilemma" in dental and other permanent implants.

Authors:  Nicholas G Fischer; Conrado Aparicio
Journal:  Bioact Mater       Date:  2022-03-19

4.  Protecting the skin-implant interface with transcutaneous silver-coated skin-and-bone-integrated pylon in pig and rabbit dorsum models.

Authors:  Maxim Shevtsov; Dmitriy Gavrilov; Natalia Yudintceva; Elena Zemtsova; Andrei Arbenin; Vladimir Smirnov; Irina Voronkina; Polina Adamova; Miralda Blinova; Nataliya Mikhailova; Oleg Galibin; Michael Akkaoui; Mark Pitkin
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2020-09-16       Impact factor: 3.405

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.