Literature DB >> 26485352

Design and Control of a Mechatronic Tracheostomy Tube for Automated Tracheal Suctioning.

Thanh Nho Do1, Tian En Timothy Seah2, Soo Jay Phee2.   

Abstract

GOAL: Mechanical ventilation is required to aid patients with breathing difficulty to breathe more comfortably. A tracheostomy tube inserted through an opening in the patient neck into the trachea is connected to a ventilator for suctioning. Currently, nurses spend millions of person-hours yearly to perform this task. To save significant person-hours, an automated mechatronic tracheostomy system is needed. This system allows for relieving nurses and other carers from the millions of person-hours spent yearly on tracheal suctioning. In addition, it will result in huge healthcare cost savings.
METHODS: We introduce a novel mechatronic tracheostomy system including the development of a long suction catheter, automatic suctioning mechanisms, and relevant control approaches to perform tracheal suctioning automatically. To stop the catheter at a desired position, two approaches are introduced: 1) Based on the known travel length of the catheter tip; 2) Based on a new sensing device integrated at the catheter tip. It is known that backlash nonlinearity between the suction catheter and its conduit as well as in the gear system of the actuator are unavoidable. They cause difficulties to control the exact position of the catheter tip. For the former case, we develop an approximate model of backlash and a direct inverse scheme to enhance the system performances. The scheme does not require any complex inversions of the backlash model and allows easy implementations. For the latter case, a new sensing device integrated into the suction catheter tip is developed and backlash compensation controls are avoided.
RESULTS: Automated suctioning validations are successfully carried out on the proposed experimental system. Comparisons and discussions are also introduced. SIGNIFICANCE: The results demonstrate a significant contribution and potential benefits to the mechanical ventilation areas.

Entities:  

Mesh:

Year:  2015        PMID: 26485352      PMCID: PMC7186034          DOI: 10.1109/TBME.2015.2491327

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  22 in total

1.  Endotracheal intubation confirmation based on video image classification using a parallel GMMs framework: a preliminary evaluation.

Authors:  Dror Lederman
Journal:  Ann Biomed Eng       Date:  2010-09-28       Impact factor: 3.934

Review 2.  Providing the nurse with a guide to tracheostomy care and management.

Authors:  Claudia Russell
Journal:  Br J Nurs       Date:  2005 Apr 28-May 11

3.  A novel airway device with tactile sensing capabilities for verifying correct endotracheal tube placement.

Authors:  Pauwel Goethals; Harshu Chaobal; Dominiek Reynaerts; David Schaner
Journal:  J Clin Monit Comput       Date:  2013-09-25       Impact factor: 2.502

4.  A novel method to position an endotracheal tube at the correct depth using an infrared sensor stylet.

Authors:  Yeongtak Song; Jaehoon Oh; Youngjoon Chee; Taeho Lim; Hyunggoo Kang; Youngsuk Cho
Journal:  Can J Anaesth       Date:  2013-02-01       Impact factor: 5.063

Review 5.  Consensus conference on artificial airways in patients receiving mechanical ventilation.

Authors:  A L Plummer; D R Gracey
Journal:  Chest       Date:  1989-07       Impact factor: 9.410

6.  Indications, timing, and techniques of tracheostomy in 152 French ICUs.

Authors:  François Blot; Christian Melot
Journal:  Chest       Date:  2005-04       Impact factor: 9.410

7.  Early vs late tracheotomy for prevention of pneumonia in mechanically ventilated adult ICU patients: a randomized controlled trial.

Authors:  Pier Paolo Terragni; Massimo Antonelli; Roberto Fumagalli; Chiara Faggiano; Maurizio Berardino; Franco Bobbio Pallavicini; Antonio Miletto; Salvatore Mangione; Angelo U Sinardi; Mauro Pastorelli; Nicoletta Vivaldi; Alberto Pasetto; Giorgio Della Rocca; Rosario Urbino; Claudia Filippini; Eva Pagano; Andrea Evangelista; Gianni Ciccone; Luciana Mascia; V Marco Ranieri
Journal:  JAMA       Date:  2010-04-21       Impact factor: 56.272

8.  Tracheostomy does not improve the outcome of patients requiring prolonged mechanical ventilation: a propensity analysis.

Authors:  Christophe Clec'h; Corinne Alberti; François Vincent; Maïté Garrouste-Orgeas; Arnaud de Lassence; Dany Toledano; Elie Azoulay; Christophe Adrie; Samir Jamali; Isabelle Zaccaria; Yves Cohen; Jean-François Timsit
Journal:  Crit Care Med       Date:  2007-01       Impact factor: 7.598

9.  Dimensions of the normal human trachea.

Authors:  E Breatnach; G C Abbott; R G Fraser
Journal:  AJR Am J Roentgenol       Date:  1984-05       Impact factor: 3.959

Review 10.  Percutaneous dilatational tracheostomy versus surgical tracheostomy in critically ill patients: a systematic review and meta-analysis.

Authors:  Anthony Delaney; Sean M Bagshaw; Marek Nalos
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

View more
  3 in total

1.  Stretchable, Twisted Conductive Microtubules for Wearable Computing, Robotics, Electronics, and Healthcare.

Authors:  Thanh Nho Do; Yon Visell
Journal:  Sci Rep       Date:  2017-05-11       Impact factor: 4.379

2.  An original design of remote robot-assisted intubation system.

Authors:  Xinyu Wang; Yuanfa Tao; Xiandong Tao; Jianglong Chen; Yifeng Jin; Zhengxiang Shan; Jiyang Tan; Qixin Cao; Tiewen Pan
Journal:  Sci Rep       Date:  2018-09-07       Impact factor: 4.379

3.  Pilot Study of Trans-oral Robotic-Assisted Needle Direct Tracheostomy Puncture in Patients Requiring Prolonged Mechanical Ventilation.

Authors:  Xiao Xiao; Howard Poon; Chwee Ming Lim; Max Q-H Meng; Hongliang Ren
Journal:  Front Robot AI       Date:  2020-11-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.