Literature DB >> 2648233

Internal suture occlusion of the Molteno glaucoma implant for the prevention of postoperative hypotony.

P R Egbert1, M F Lieberman.   

Abstract

The Molteno glaucoma drainage implant procedure is useful for managing refractory glaucoma, but a significant concern has been the avoidance of postoperative hypotony due to temporary excessive filtration. We have developed a method of temporarily closing the translimbal tube with an internally-placed occluding suture (4-0 or 5-0 chromic). Seven to 12 days later this suture was removed, without surgery, in an outpatient setting. We have used this method on 30 patients. The advantages are that postoperative hypotony is reduced, and the Molteno drainage implant can be inserted in a single operation.

Entities:  

Mesh:

Year:  1989        PMID: 2648233

Source DB:  PubMed          Journal:  Ophthalmic Surg        ISSN: 0022-023X


  10 in total

Review 1.  Glaucoma drainage devices; past, present, and future.

Authors:  K S Lim; B D Allan; A W Lloyd; A Muir; P T Khaw
Journal:  Br J Ophthalmol       Date:  1998-09       Impact factor: 4.638

2.  Efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma.

Authors:  J S Lai; A S Poon; J K Chua; C C Tham; A T Leung; D S Lam
Journal:  Br J Ophthalmol       Date:  2000-07       Impact factor: 4.638

3.  Control and optimisation of fluid flow in glaucoma drainage device surgery.

Authors:  Kin Sheng Lim
Journal:  Eye (Lond)       Date:  2018-01-19       Impact factor: 3.775

4.  Transvitreal endocyclophotocoagulation.

Authors:  J A Haller
Journal:  Trans Am Ophthalmol Soc       Date:  1996

5.  Combining Baerveldt Implant with Trabectome Negates Tube Fenestration: A Coarsened-matched Comparison.

Authors:  Hamed Esfandiari; Kiana Hassanpour; Peter Knowlton; Tarek Shazly; Mehdi Yaseri; Nils A Loewen
Journal:  J Ophthalmic Vis Res       Date:  2020-10-25

6.  Clinical outcomes of Ahmed glaucoma valve implantation using tube ligation and removable external stents.

Authors:  Jong Joo Lee; Ki Ho Park; Dong Myung Kim; Tae Woo Kim
Journal:  Korean J Ophthalmol       Date:  2009-06-09

7.  Performance of and Pressure Elevation Formed by Small-diameter Microtubes Used in Constant-flow Sets.

Authors:  Sae Woon Sohn; Myounggyu D Noh; Jong-Hyun Lee; Kyoung Nam Kim; Chang-Sik Kim; Byung Heon Ahn
Journal:  Korean J Ophthalmol       Date:  2016-05-18

8.  The efficacy of Alahmady ring implantation in the management of neovascular glaucoma.

Authors:  Alahmady H Alsmman; Gamal Radwan; Mohammed Elagouz; Usama Ali Mohammed
Journal:  Clin Ophthalmol       Date:  2017-03-20

9.  Evaluation of the Ultrastructural and In Vitro Flow Properties of the PRESERFLO MicroShunt.

Authors:  Marta Ibarz Barberá; Jose Luis Hernández-Verdejo; Jean Bragard; Javier Burguete; Laura Morales Fernández; Pedro Tañá Rivero; Rosario Gómez de Liaño; Miguel A Teus
Journal:  Transl Vis Sci Technol       Date:  2021-11-01       Impact factor: 3.283

10.  A modified technique for intraluminal stenting of glaucoma drainage devices: The guide-wire technique.

Authors:  Nicholas H Andrew; Sonia G Huang; Jamie E Craig
Journal:  Indian J Ophthalmol       Date:  2020-06       Impact factor: 1.848

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.