Literature DB >> 26481393

A radiopaque polymer hydrogel used as a fiducial marker in gynecologic-cancer patients receiving brachytherapy.

Ryan J Bair1, Eric Bair2, Akila N Viswanathan3.   

Abstract

PURPOSE: We assessed a novel Food and Drug Administration-approved hydrogel, synthesized as absorbable iodinated particles, in gynecologic-cancer patients undergoing computed tomography (CT) or magnetic resonance (MR) based brachytherapy after external beam radiation. METHODS AND MATERIALS: Nineteen patients underwent CT-guided (n = 13) or MR-guided (n = 6) brachytherapy for gynecologic cancers. Seventy-seven hydrogel injections were placed. The hydrogel material was injected into gross residual disease and/or key anatomic landmarks in amounts ranging from 0.1 to 0.4 mL. The visibility of the tracer was scored on CT and on MR images using a 5-point scoring scale. A Cohen's kappa statistic was calculated to assess interobserver agreement. To assess the unadjusted effects of baseline parameters on hydrogel visibility, we modeled visibility using a linear mixed-effect model.
RESULTS: Injections were without complication. The kappa statistic was 0.77 (95% confidence interval [CI], 0.68-0.87). The volume of hydrogel injected was significantly associated with visibility on both CT (p = 0.032) and magnetic resonance imaging (p = 0.016). We analyzed visibility by location, controlling for amount. A 0.1-cc increase in volume injected was associated with increases of 0.54 (95% CI = 0.05-1.03) in the CT visibility score and 0.83 (95% CI = 0.17-1.49) in the MR visibility score. Injection of 0.4 cc or more was required for unequivocal visibility on CT or MR. No statistically significant correlation was found between tumor type, tumor location, or anatomical location of injection and visibility on either CT or magnetic resonance imaging.
CONCLUSIONS: In this first report of an injectable radiopaque hydrogel, targets were visualized to assist with three-dimensional-based brachytherapy in gynecologic malignancies. This marker has potential for several applications, is easy to inject and visualize, and caused no acute complications.
Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Brachytherapy; Fiducial; Radiopaque polymer hydrogel

Mesh:

Substances:

Year:  2015        PMID: 26481393      PMCID: PMC4914602          DOI: 10.1016/j.brachy.2015.08.008

Source DB:  PubMed          Journal:  Brachytherapy        ISSN: 1538-4721            Impact factor:   2.362


  26 in total

1.  Daily online cone beam computed tomography to assess interfractional motion in patients with intact cervical cancer.

Authors:  Neelam Tyagi; John H Lewis; Catheryn M Yashar; Daniel Vo; Steve B Jiang; Arno J Mundt; Loren K Mell
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-11-23       Impact factor: 7.038

2.  Polyethylene glycol hydrogel spinal sealant (DuraSeal Spinal Sealant) as an adjunct to sutured dural repair in the spine: results of a prospective, multicenter, randomized controlled study.

Authors:  Kee D Kim; Neill M Wright
Journal:  Spine (Phila Pa 1976)       Date:  2011-11-01       Impact factor: 3.468

3.  Safety and efficacy of percutaneous fiducial marker implantation for image-guided radiation therapy.

Authors:  Nishita Kothary; Jeremy J Heit; John D Louie; William T Kuo; Billy W Loo; Albert Koong; Daniel T Chang; David Hovsepian; Daniel Y Sze; Lawrence V Hofmann
Journal:  J Vasc Interv Radiol       Date:  2008-11-18       Impact factor: 3.464

4.  Novel use of a hydrogel spacer permits reirradiation in otherwise incurable recurrent gynecologic cancers.

Authors:  Akila N Viswanathan; Antonio L Damato; Paul L Nguyen
Journal:  J Clin Oncol       Date:  2013-10-21       Impact factor: 44.544

5.  An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-06       Impact factor: 2.571

6.  Dose-volume histogram parameters and late side effects in magnetic resonance image-guided adaptive cervical cancer brachytherapy.

Authors:  Petra Georg; Stefan Lang; Johannes C A Dimopoulos; Wolfgang Dörr; Alina E Sturdza; Daniel Berger; Dietmar Georg; Christian Kirisits; Richard Pötter
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-04-10       Impact factor: 7.038

7.  A prospective trial of real-time magnetic resonance-guided catheter placement in interstitial gynecologic brachytherapy.

Authors:  Akila N Viswanathan; Jackie Szymonifka; Clare M Tempany-Afdhal; Desmond A O'Farrell; Robert A Cormack
Journal:  Brachytherapy       Date:  2013-02-12       Impact factor: 2.362

8.  Application technique: placement of a prostate-rectum spacer in men undergoing prostate radiation therapy.

Authors:  Gencay Hatiboglu; Michael Pinkawa; Jean-Paul Vallée; Boris Hadaschik; Markus Hohenfellner
Journal:  BJU Int       Date:  2012-07-12       Impact factor: 5.588

9.  A prospective randomized single-blind trial of patient comfort following vessel closure: extravascular synthetic sealant closure provides less pain than a self-tightening suture vascular compression device.

Authors:  Kyle M Fargen; Brian L Hoh; J Mocco
Journal:  J Neurointerv Surg       Date:  2011-01-24       Impact factor: 5.836

10.  Variability of the carina-incisor distance as assessed by endoscopic ultrasound.

Authors:  P F Rice; T L D Crosby; S A Roberts
Journal:  Clin Oncol (R Coll Radiol)       Date:  2003-10       Impact factor: 4.126

View more
  11 in total

1.  A Novel Absorbable Radiopaque Hydrogel Spacer to Separate the Head of the Pancreas and Duodenum in Radiation Therapy for Pancreatic Cancer.

Authors:  Avani D Rao; Ziwei Feng; Eun Ji Shin; Jin He; Kevin M Waters; Stephanie Coquia; Robert DeJong; Lauren M Rosati; Lin Su; Dengwang Li; Juan Jackson; Stephen Clark; Jeffrey Schultz; Danielle Hutchings; Seong-Hun Kim; Ralph H Hruban; Theodore L DeWeese; John Wong; Amol Narang; Joseph M Herman; Kai Ding
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-08-14       Impact factor: 7.038

2.  Hydrogels for localized chemotherapy of liver cancer: a possible strategy for improved and safe liver cancer treatment.

Authors:  Jianyong Ma; Bingzhu Wang; Haibin Shao; Songou Zhang; Xiaozhen Chen; Feize Li; Wenqing Liang
Journal:  Drug Deliv       Date:  2022-12       Impact factor: 6.819

3.  Calcium Phosphate Cement Paste Injection as a Fiducial Marker of Cervical Cancer.

Authors:  Ichiro Ogino; Masakazu Kitagawa; Shigenobu Watanabe; Hiroshi Yoshida; Masaharu Hata
Journal:  In Vivo       Date:  2018 Nov-Dec       Impact factor: 2.155

Review 4.  Detecting and Monitoring Hydrogels with Medical Imaging.

Authors:  Yuxi C Dong; Mathilde Bouché; Selen Uman; Jason A Burdick; David P Cormode
Journal:  ACS Biomater Sci Eng       Date:  2021-05-12

5.  Demonstration of Safety and Feasibility of Hydrogel Marking of the Pancreas-Duodenum Interface for Image Guided Radiation Therapy (IGRT) in a Porcine Model: Implications in IGRT for Pancreatic Cancer Patients.

Authors:  Avani D Rao; Eun Ji Shin; Sarah E Beck; Caroline Garrett; Seong-Hun Kim; Nam Ju Lee; Eleni Liapi; John Wong; Joseph Herman; Amol Narang; Kai Ding
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-03-02       Impact factor: 7.038

6.  Fiducial markers visibility and artefacts in prostate cancer radiotherapy multi-modality imaging.

Authors:  Sarah O S Osman; Emily Russell; Raymond B King; Karen Crowther; Suneil Jain; Cormac McGrath; Alan R Hounsell; Kevin M Prise; Conor K McGarry
Journal:  Radiat Oncol       Date:  2019-12-26       Impact factor: 3.481

7.  The Feasibility of Haar Feature-Based Endoscopic Ultrasound Probe Tracking for Implanting Hydrogel Spacer in Radiation Therapy for Pancreatic Cancer.

Authors:  Ziwei Feng; Hamed Hooshangnejad; Eun Ji Shin; Amol Narang; Muyinatu A Lediju Bell; Kai Ding
Journal:  Front Oncol       Date:  2021-11-04       Impact factor: 6.244

8.  Modular polymer platform as a novel approach to head and neck cancer therapy.

Authors:  Yazeed Alhiyari; Jundong Shao; Albert Y Han; Amanda Miller; Jeffrey F Krane; Marie Luff; Milica Momcilovic; David Shackelford; Zhen Gu; Maie A St John
Journal:  Sci Rep       Date:  2022-03-04       Impact factor: 4.379

9.  Prospective observational study on the safety of an original fiducial marker insertion for radiotherapy in gynecological cancer by a simple method.

Authors:  Shuhei Sekii; Kayoko Tsujino; Hikaru Kubota; Satoshi Yamaguchi; Kengo Kosaka; Shuichiro Miyazaki; Nor Shazrina Sulaiman; Yoko Matsumoto; Yosuke Ota; Toshinori Soejima; Ryohei Sasaki
Journal:  J Radiat Res       Date:  2019-11-22       Impact factor: 2.724

Review 10.  Stimuli-Responsive Hydrogels for Cancer Treatment: The Role of pH, Light, Ionic Strength and Magnetic Field.

Authors:  Fernanda Andrade; Maria Mercé Roca-Melendres; Esteban F Durán-Lara; Diana Rafael; Simó Schwartz
Journal:  Cancers (Basel)       Date:  2021-03-09       Impact factor: 6.639

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.