Literature DB >> 26478291

Direct electrochemistry of hemoglobin and biosensing for hydrogen peroxide using a film containing silver nanoparticles and poly(amidoamine) dendrimer.

Marina Baccarin1, Bruno C Janegitz2, Rodrigo Berté3, Fernando Campanhã Vicentini4, Craig E Banks5, Orlando Fatibello-Filho4, Valtencir Zucolotto3.   

Abstract

A new architecture for a biosensor is proposed using a glassy carbon electrode (GCE) modified with hemoglobin (Hb) and silver nanoparticles (AgNPs) encapsulated in poly(amidoamine) dendrimer (PAMAM). The biosensors were characterized using ultraviolet-visible spectroscopy, ζ-potential and cyclic voltammetry to investigate the interactions between Hb, AgNPs and the PAMAM film. The biosensor exhibited a well-defined cathodic peak attributed to reduction of the Fe(3+) present in the heme group in Hb, as revealed by cyclic voltammetry in the presence of O2. An apparent heterogeneous electron transfer rate of 4.1s(-1) was obtained. The Hb-AgNPs-PAMAM/GCE third generation biosensor was applied in the amperometric determination of hydrogen peroxide over the linear range from 6.0 × 10(-6) to 9.1 × 10(-5)mol L(-1) with a detection limit of 4.9 × 1 0(-6)mol L(-1). The proposed method can be extended to immobilize and evaluate the direct electron transfer of other redox enzymes.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Direct electron transfer; Hemoglobin; Hydrogen peroxide; Silver nanoparticles; Third generation biosensor

Mesh:

Substances:

Year:  2015        PMID: 26478291     DOI: 10.1016/j.msec.2015.08.013

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  5 in total

1.  Myoglobin immobilized on mesoporous carbon foam in a hydrogel (selep) dispersant for voltammetric sensing of hydrogen peroxide.

Authors:  Mojtaba Jahanbakhshi
Journal:  Mikrochim Acta       Date:  2018-01-19       Impact factor: 5.833

2.  Electrochemical Aptatoxisensor Responses on Nanocomposites Containing Electro-Deposited Silver Nanoparticles on Poly(Propyleneimine) Dendrimer for the Detection of Microcystin-LR in Freshwater.

Authors:  Mawethu P Bilibana; Avril R Williams; Candice Rassie; Christopher E Sunday; Hlamulo Makelane; Lindsay Wilson; Nomaphelo Ntshongontshi; Abongile N Jijana; Milua Masikini; Priscilla G L Baker; Emmanuel I Iwuoha
Journal:  Sensors (Basel)       Date:  2016-11-11       Impact factor: 3.576

3.  Aza-heterocyclic Receptors for Direct Electron Transfer Hemoglobin Biosensor.

Authors:  Vinay Kumar; D M Nikhila Kashyap; Suraj Hebbar; R Swetha; Sujay Prasad; T Kamala; S S Srikanta; P R Krishnaswamy; Navakanta Bhat
Journal:  Sci Rep       Date:  2017-02-07       Impact factor: 4.379

Review 4.  Dendrimers as Soft Nanomaterials for Electrochemical Immunosensors.

Authors:  Alfredo Sánchez; Anabel Villalonga; Gonzalo Martínez-García; Concepción Parrado; Reynaldo Villalonga
Journal:  Nanomaterials (Basel)       Date:  2019-12-07       Impact factor: 5.076

5.  Carbon dot based nucleus targeted fluorescence imaging and detection of nuclear hydrogen peroxide in living cells.

Authors:  Kabyashree Phukan; Ritwick Ranjan Sarma; Somarani Dash; Rajlakshmi Devi; Devasish Chowdhury
Journal:  Nanoscale Adv       Date:  2021-10-20
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.