Association of Implantable Cardioverter Defibrillator Therapy with All-Cause Mortality-A Systematic Review and Meta-Analysis.

Zhiyong Qian1,2, Zhiyong Zhang1, Jianghong Guo1, Yao Wang1, Xiaofeng Hou1, Guangzhi Feng2, Jiangang Zou1.   

Abstract

BACKGROUND: Implantable cardioverter defibrillators (ICDs) have become the standard approach for prevention of sudden cardiac death. Whether ICD therapy is an independent predictor of all-cause mortality is controversial. We made the systematic review and meta-analysis to estimate the impact of ICD therapy on mortality.
METHODS: We searched the PubMed and Embase databases for studies evaluating the effect of ICD shocks or antitachycardia pacing (ATP) on mortality. Hazard ratios (HRs) with 95% confidence intervals (CIs) were calculated using random effects models.
RESULTS: Thirteen cohort studies were identified. Mean ejection fraction of the population was 23-35%; 68.0% had ischemic etiology, and 74.5% received a primary prevention ICD implantation. Appropriate shocks were an independent predictor of increased mortality compared with no-shock or no-therapy patients (HR 2.07, 2.76, respectively). In contrast, inconsistent results were obtained during inappropriate-shock analyses: when compared with no-shock patients, inappropriate shocks were associated with an increased risk of death (HR 1.54, 95% CI: 1.25-1.89, P < 0.0001); however, when compared to no-therapy patients, there was no relationship between inappropriate shocks and mortality (HR 1.20, 95% CI: 0.90-1.61, P = 0.22). Subgroup analysis in heart failure patients also did not find any difference in mortality between inappropriate-shock and no-therapy patients. No increased risk of mortality was found in the patients who experienced appropriate or inappropriate ATP only.
CONCLUSION: Appropriate shocks were associated with an increased mortality in ICD patients. However, whether inappropriate shocks worsened the clinical outcome was controversial, and larger prospective trials are needed to clarify the issue. ©2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  antitachycardia pacing; appropriate shocks; implantable cardioverter defibrillator; inappropriate shocks; mortality

Mesh:

Year:  2015        PMID: 26470761     DOI: 10.1111/pace.12766

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

1.  Prognostic impact of recurrences of ventricular tachyarrhythmias and appropriate ICD therapies in a high-risk ICD population.

Authors:  Tobias Schupp; Ibrahim Akin; Linda Reiser; Armin Bollow; Gabriel Taton; Thomas Reichelt; Dominik Ellguth; Niko Engelke; Uzair Ansari; Kambis Mashayekhi; Christel Weiß; Christoph Nienaber; Muharrem Akin; Martin Borggrefe; Michael Behnes
Journal:  Clin Res Cardiol       Date:  2019-02-12       Impact factor: 5.460

2.  A case of withheld defibrillator treatment for 9 minutes of ventricular tachycardia.

Authors:  Evan Grove; Vincent Y See; Timm M Dickfeld
Journal:  HeartRhythm Case Rep       Date:  2020-11-20