Literature DB >> 26469147

A 3-D "Super Surface" Combining Modern Intraocular Lens Formulas to Generate a "Super Formula" and Maximize Accuracy.

John G Ladas1, Aazim A Siddiqui1, Uday Devgan2, Albert S Jun1.   

Abstract

IMPORTANCE: Cataract surgery is the most common eye surgery. Calculating the most accurate power of the intraocular lens (IOL) is a critical factor in optimizing patient outcomes.
OBJECTIVES: To develop a graphical method for displaying IOL calculation formulas in 3 dimensions, and to describe a method that uses the most accurate and current information on IOL formulas, adjustments, and lens design to create one "super surface" and develop an IOL "super formula." DESIGN, SETTING, AND PARTICIPANTS: A numerical computing environment was used to create 3-D surfaces of IOL formulas: Hoffer Q, Holladay I, Holladay I with Koch adjustment, Haigis, and SRK/T. The surfaces were then analyzed to determine where the IOL powers calculated by each formula differed by more than 0.5, 1.0, and 1.5 diopters (D) from each of the other formulas. Next, based on the current literature and empirical knowledge, a super surface was rendered that incorporated the ideal portions from 4 of the 5 formulas to generate a super formula. Last, IOL power values of a set of 100 eyes from consecutive patients at an eye institute were calculated using the 5 formulas and super formula. The study was performed from December 11, 2014, to April 20, 2015. Analysis was conducted from February 18 to May 6, 2015. MAIN OUTCOMES AND MEASURES: Intraocular lens power value in diopters and the magnitude of disparity between an existing individual IOL formula and our super formula.
RESULTS: In the 100 eyes tested, the super formula localized to the correct portion of the super surface 100% of the time and thus chose the most appropriate IOL power value. The individual formulas deviated from the optimal super formula IOL power values by more than 0.5 D 30% of the time in Hoffer Q, 16% in Holladay I, 22% in Holladay I with Koch adjustment, 48% in Haigis, and 24% in SRK/T. CONCLUSIONS AND RELEVANCE: A novel method was developed to represent IOL formulas in 3 dimensions. An IOL super formula was formulated that incorporates the ideal segments from each of the existing formulas and uses the ideal IOL formula for an individual eye. The expectation is that this method will broaden the conceptual understanding of IOL calculations, improve clinical outcomes for patients, and stimulate further progress in IOL formula research.

Entities:  

Mesh:

Year:  2015        PMID: 26469147     DOI: 10.1001/jamaophthalmol.2015.3832

Source DB:  PubMed          Journal:  JAMA Ophthalmol        ISSN: 2168-6165            Impact factor:   7.389


  16 in total

1.  Comparing the accuracy of new intraocular lens power calculation formulae in short eyes after cataract surgery: a systematic review and meta-analysis.

Authors:  Yu Luo; Hongyu Li; Lixiong Gao; Jinlin Du; Wenqian Chen; Yi Gao; Zi Ye; Zhaohui Li
Journal:  Int Ophthalmol       Date:  2022-01-26       Impact factor: 2.031

2.  Comparing the accuracy of the new-generation intraocular lens power calculation formulae in axial myopic eyes: a meta-analysis.

Authors:  Hongyu Li; Zi Ye; Yu Luo; Zhaohui Li
Journal:  Int Ophthalmol       Date:  2022-09-05       Impact factor: 2.029

3.  Algorithmic intraocular lens power calculation formula selection by keratometry, anterior chamber depth and axial length.

Authors:  Jung Wan Kim; Youngsub Eom; Eun Gyu Yoon; Young Choi; Jong Suk Song; Ji Won Jeong; Seh Kwang Park; Hyo Myung Kim
Journal:  Acta Ophthalmol       Date:  2021-08-11       Impact factor: 3.988

4.  Predictability of pseudophakic refraction using patient-customized paraxial eye models.

Authors:  Yu-Cherng Chang; Florence Cabot; Bianca Maceo Heilman; Larissa Meza; Marco Ruggeri; Arthur Ho; Sonia H Yoo; Jean-Marie Parel; Fabrice Manns
Journal:  J Cataract Refract Surg       Date:  2022-09-01       Impact factor: 3.528

5.  Accuracy of intraocular lens power calculation in primary angle-closure disease: comparison of 7 formulas.

Authors:  Min Hou; Yujie Ding; Liangping Liu; Jianbing Li; Xing Liu; Mingxing Wu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-07-14       Impact factor: 3.117

Review 6.  Intraocular lens calculations in atypical eyes.

Authors:  Aazim A Siddiqui; Uday Devgan
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

7.  The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas.

Authors:  Jinho Jeong; Han Song; Jimmy K Lee; Roy S Chuck; Ji-Won Kwon
Journal:  BMC Ophthalmol       Date:  2017-05-02       Impact factor: 2.209

8.  Comparison of axial length, anterior chamber depth and intraocular lens power between IOLMaster and ultrasound in normal, long and short eyes.

Authors:  Jing Dong; Yaqin Zhang; Haining Zhang; Zhijie Jia; Suhua Zhang; Xiaogang Wang
Journal:  PLoS One       Date:  2018-03-15       Impact factor: 3.240

9.  Accuracy of biometry using automated and manual keratometry for intraocular lens power calculation.

Authors:  Lubna Khan; Babita Sharma; Harshal Gupta; Rimpi Rana
Journal:  Taiwan J Ophthalmol       Date:  2018 Apr-Jun

Review 10.  Update on Intraocular Lens Formulas and Calculations.

Authors:  Tina Xia; Christine E Martinez; Linda M Tsai
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2020 May-Jun
View more