Evaluation of a hand-held blood gas analyzer for rapid determination of blood gases, electrolytes and metabolites in intensive care setting.

Antti A M Luukkonen, Tiina M Lehto, Pirjo S M Hedberg, Tommy E Vaskivuo.   

Abstract

BACKGROUND: Intensive care units, operating rooms, emergency departments, and neonatology units need rapid measurements of blood gases, electrolytes, and metabolites. These analyses can be performed in a central laboratory or at the clinic with traditional or compact cassette-type blood gas analyzers such as the epoc blood gas testing system for analyzing whole blood samples at the bedside. In this study, the performance and interchangeability of a hand-held epoc blood gas analyzer was evaluated.
METHODS: The analytical performance of the epoc analyzer was evaluated by determining within-and between-run precisions. The accuracy of the epoc analyzer was assessed by comparing patient results from the device with those obtained with the Siemens Rapidlab 1265 and Rapidpoint RP500 and Siemens Dimension Vista and Sysmex XE-2100 analyzers. The following parameters were measured: pH, pCO2, pO2, Hb (calc), Na+, K+, iCa2+, glucose, and lactate.
RESULTS: The CV% of the epoc's between-day imprecision for the various parameters varied from 0.4 to 8.6. The within-run imprecision CV% varied from 0.6 to 5.2. The squared regression coefficient (R2) between the epoc and RL1265 varied from 0.94 to 0.99, with the exception of Na+ and Ca2+ (R2≥0.82). The correlation (R2) of Na+ and K+ between epoc and Dimension Vista was 0.73 and 0.89, respectively. The correlation (R2) of Hb between the epoc and the XE-2100 analyzer was 0.94.
CONCLUSIONS: With most of the measured blood gas parameters, the epoc analyzer correlated well with reference techniques. The epoc analyzer is suitable for rapid measurement of the blood gases, the electrolytes, and the metabolites in the ICU.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26457784     DOI: 10.1515/cclm-2015-0592

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  6 in total

Review 1.  Point-of-Care Diagnostics: Recent Developments in a Connected Age.

Authors:  Samiksha Nayak; Nicole R Blumenfeld; Tassaneewan Laksanasopin; Samuel K Sia
Journal:  Anal Chem       Date:  2016-12-13       Impact factor: 6.986

2.  Validation of a Portable Blood Gas Analyzer for Use in Challenging Field Conditions at High Altitude.

Authors:  Janek Nawrocki; Michael Furian; Aline Buergin; Laura Mayer; Simon Schneider; Maamed Mademilov; Madeleine S Bloch; Talant M Sooronbaev; Silvia Ulrich; Konrad E Bloch
Journal:  Front Physiol       Date:  2021-01-08       Impact factor: 4.566

Review 3.  Carbon Dioxide Sensing-Biomedical Applications to Human Subjects.

Authors:  Emmanuel Dervieux; Michaël Théron; Wilfried Uhring
Journal:  Sensors (Basel)       Date:  2021-12-28       Impact factor: 3.576

4.  Performance evaluation of all analytes on the epoc® Blood Analysis System for use in hospital surgical and intensive care units.

Authors:  Zahraa Mohammed-Ali; Sousan Bagherpoor; Pauline Diker; Thuy Hoang; Ivana Vidovic; Christine Cursio; Felix Leung; Davor Brinc
Journal:  Pract Lab Med       Date:  2020-11-25

5.  Accuracy of Potassium Measurement Using Blood Gas Analyzer.

Authors:  Hatim Mahmoud; Zied Jaffar; Yousef M Al Alawi; Fatimah Al Alsuhaimi; Mohammed A A Khoja; Muath A Al-Ahmadi; Abdullah M Alattas; Mohammed F Alhusayni; Mohammed E Mahroos; Muath A Alrehaili
Journal:  Cureus       Date:  2022-03-30

6.  Impact of point-of-care panel tests in ambulatory care: a systematic review and meta-analysis.

Authors:  Clare Goyder; Pui San Tan; Jan Verbakel; Thanusha Ananthakumar; Joseph J Lee; Gail Hayward; Philip J Turner; Ann Van Den Bruel
Journal:  BMJ Open       Date:  2020-02-27       Impact factor: 2.692

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.