Feasibility of 320-row multi-detector computed tomography angiography to assess bioabsorbable everolimus-eluting vascular scaffolds.

Masahiko Asami1, Jiro Aoki1, Patrick W Serruys2, Alexandre Abizaid3, Shigeru Saito4, Yoshinobu Onuma2, Takeshi Kimura5, Charles A Simonton6, Kengo Tanabe7.   

Abstract

Coronary computer tomographic angiography (CCTA) for screening intra-arterial vessel disease is gaining rapid clinical acceptance in recent years, but its use for such assessments in metal-stented vessel segments is very limited due to blooming artifacts introduced by the metal. However, vessel segments treated by the polymeric everolimus-eluting bioresorbable vascular scaffolds (Absorb) are readily monitored for intravascular disease over time with CCTA. The data on the accuracy of multi-detector computed tomography (MDCT) in patients treated with Absorb is still sparse. Results on 5 Japanese case studies from ABSORB EXTEND are presented here. Five patients were treated with Absorb, and follow-up angiography was conducted at 8 to 14 months as per routine site standard of practice. 320-row MDCT scan was performed within 1 month before the angiography. By MDCT, all Absorb-treated lesions were clearly evaluated and restenosis were not observed. Minimal diameter and % diameter stenosis were similar between MDCT and quantitative angiography (2.07 ± 0.13 vs. 2.03 ± 0.06 mm, P = 0.86, and 22.5 ± 5.0 vs. 21.5 ± 4.5 %, P = 0.88, respectively). MDCT appears to be feasible and useful for evaluating lumen patency and vessel disease in segments implanted with Absorb at follow-up.

Entities:  

Keywords:  Bioabsorbable; Coronary artery disease; Multi-detector computed tomography; Optical coherence tomography; STENT

Mesh:

Substances:

Year:  2015        PMID: 26445951     DOI: 10.1007/s12928-015-0353-1

Source DB:  PubMed          Journal:  Cardiovasc Interv Ther        ISSN: 1868-4297


  2 in total

1.  Appearance of bioresorbable vascular scaffolds on computed tomography coronary angiography.

Authors:  Siong Sung Wong; Gunasekaran Ramsamy
Journal:  Singapore Med J       Date:  2017-07-06       Impact factor: 1.858

Review 2.  Methods to assess bioresorbable vascular scaffold devices behaviour after implantation.

Authors:  Alberto Pernigotti; Elisabetta Moscarella; Giosafat Spitaleri; Claudia Scardino; Kohki Ishida; Salvatore Brugaletta
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.