The arterial pressure waveform during acute ventricular failure and synchronized external chest compression.

R Pizov1, Y Ya'ari, A Perel.   

Abstract

Methods for mechanical cardiac support by intermittent increases in the intrathoracic pressure have recently been described. In the present study the responses of the arterial pressure waveform to mechanical ventilation with and without synchronized external chest compression (SEC) in the presence of acute ventricular failure (AVF) were evaluated by measuring the systolic pressure variation (SPV). SPV, the difference between the maximal and minimal values of systolic blood during a single positive pressure breath, consists of delta up and delta down components when systolic blood pressure during a short apnea is used as reference value. During intermittent positive pressure ventilation (IPPV) alone, AVF caused SPV to decrease significantly from 8.8 +/- 4.0 to 5.7 +/- 1.9 mm Hg, and further to 3.1 +/- 1.1 mm Hg after volume loading (P less than 0.02). The decrease in SPV was due to a significant decrease in the delta down component, whereas the delta up became the major component of the reduced SPV. The application of SEC caused significant increases in the delta down, delta up, and overall SPV during AVF without volume loading. However, during AVF with volume loading, SEC increased only the delta up component of the SPV, signifying a transient increase in the left ventricular stroke output. It is concluded that the disappearance of the delta down component of the SPV is characteristic of congestive heart failure. Analysis of the arterial waveform offers a readily available monitoring tool for the differentiation of the possible effects on increased intrathoracic pressure.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1989        PMID: 2643888     DOI: 10.1213/00000539-198902000-00015

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  12 in total

1.  Systolic blood pressure at end-expiration measured by the automated systolic pressure variation monitor is equivalent to systolic blood pressure during apnea.

Authors:  H A Schwid; G A Rooke
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

Review 2.  Pulse pressure variation: where are we today?

Authors:  Maxime Cannesson; Mateo Aboy; Christoph K Hofer; Mohamed Rehman
Journal:  J Clin Monit Comput       Date:  2011-02       Impact factor: 2.502

Review 3.  Interactions between respiration and systemic hemodynamics. Part II: practical implications in critical care.

Authors:  François Feihl; Alain F Broccard
Journal:  Intensive Care Med       Date:  2008-09-30       Impact factor: 17.440

Review 4.  Value of measuring esophageal pressure to evaluate heart-lung interactions-applications for invasive hemodynamic monitoring.

Authors:  Xavier Repessé; Antoine Vieillard-Baron; Guillaume Geri
Journal:  Ann Transl Med       Date:  2018-09

Review 5.  Respiratory variations in the arterial pressure during mechanical ventilation reflect volume status and fluid responsiveness.

Authors:  Azriel Perel; Reuven Pizov; Shamay Cotev
Journal:  Intensive Care Med       Date:  2014-04-16       Impact factor: 17.440

6.  Low pulmonary compliance and/or tachycardia may reduce arterial pressure variations despite hypovolemia.

Authors:  G Mion; C Descraques
Journal:  Intensive Care Med       Date:  1993       Impact factor: 17.440

7.  A Century of Technology in Anesthesia & Analgesia.

Authors:  Jane S Moon; Maxime Cannesson
Journal:  Anesth Analg       Date:  2022-07-15       Impact factor: 6.627

8.  Clinical applications of photoplethysmography in paediatric intensive care.

Authors:  Bernhard Frey; Katharina Waldvogel; Christian Balmer
Journal:  Intensive Care Med       Date:  2007-12-11       Impact factor: 17.440

9.  Perioperative intravascular fluid assessment and monitoring: a narrative review of established and emerging techniques.

Authors:  Sumit Singh; Ware G Kuschner; Geoffrey Lighthall
Journal:  Anesthesiol Res Pract       Date:  2011-07-12

Review 10.  Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation.

Authors:  F Michard; J L Teboul
Journal:  Crit Care       Date:  2000-09-01       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.